Calibration and quality assurance for rounded leaf-end MLC systems.

Multileaf collimator (MLC) systems are available on most commercial linear accelerators, and many of these MLC systems utilize a design with rounded leaf ends and linear motion of the leaves. In this kind of system, the agreement between the digital MLC position readouts and the light field or radiation field edges must be achieved with software, since the leaves do not move in a focused motion like that used for most collimator jaw systems. In this work we address a number of the calibration and quality assurance issues associated with the acceptance, commissioning, and routine clinical use of this type of MLC system. These issues are particularly important for MLCs used for various types of intensity modulated radiation therapy (IMRT) and small, conformal fields. For rounded leaf end MLCs, it is generally not possible to make both the light and radiation field edges agree with the digital readout, so differences between the two kinds of calibrations are illustrated in this work using one vendor's MLC system. It is increasingly critical that the MLC leaf calibration be very consistent with the radiation field edges, so in this work a methodology for performing accurate radiation field size calibration is discussed. A system external to the vendor's MLC control system is used to correct or handle limitations in the MLC control system. When such a system of corrections is utilized, it is found that the MLC radiation field size can be defined with an accuracy of approximately 0.3 mm, much more accurate than most vendor's specifications for MLC accuracy. Quality assurance testing for such a calibration correction system is also demonstrated.

[1]  E E Klein,et al.  A quality assurance program for ancillary high technology devices on a dual-energy accelerator. , 1996, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[2]  A L Boyer,et al.  Intensity-modulated radiation therapy with dynamic multileaf collimators. , 1999, Seminars in radiation oncology.

[3]  Yan Chen,et al.  Calculation of x-ray transmission through a multileaf collimator. , 2000, Medical physics.

[4]  S. Spirou,et al.  Generation of arbitrary intensity profiles by dynamic jaws or multileaf collimators. , 1994, Medical physics.

[5]  M. Evans,et al.  A simple technique for film dosimetry. , 1992, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[6]  D A Low,et al.  Clinical implementation of a commercial multileaf collimator: dosimetry, networking, simulation, and quality assurance. , 1995, International journal of radiation oncology, biology, physics.

[7]  S Mutic,et al.  Characterization of a commercial multileaf collimator used for intensity modulated radiation therapy. , 2001, Medical physics.

[8]  James M. Galvin,et al.  CHARACTERIZATION OF A MULTILEAF COLLIMATOR SYSTEM , 1993 .

[9]  D L McShan,et al.  Mechanical and dosimetric quality control for computer controlled radiotherapy treatment equipment. , 1995, Medical physics.

[10]  C. Ling,et al.  Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapy. , 1998, Medical physics.

[11]  P. C. Williams,et al.  Requirements for leaf position accuracy for dynamic multileaf collimation. , 2000, Physics in medicine and biology.

[12]  C D Mubata,et al.  A quality assurance procedure for the Varian multi-leaf collimator. , 1997, Physics in medicine and biology.

[13]  G T Chen,et al.  Intensity modulated radiotherapy dose delivery error from radiation field offset inaccuracy. , 2000, Medical physics.

[14]  T LoSasso,et al.  Testing of dynamic multileaf collimation. , 1996, Medical physics.

[15]  Mohan Field Shaping for Three-Dimensional Conformal Radiation Therapy and Multileaf Collimation. , 1995, Seminars in radiation oncology.

[16]  P. C. Williams,et al.  The design and performance characteristics of a multileaf collimator , 1994, Physics in medicine and biology.

[17]  D L McShan,et al.  A computer-controlled conformal radiotherapy system. I: Overview. , 1995, International journal of radiation oncology, biology, physics.

[18]  T LoSasso,et al.  Dosimetric verification of intensity-modulated fields. , 1996, Medical physics.