A comparison of the STORZ video laryngoscope and standard direct laryngoscopy for intubation in the Pediatric airway – a randomized clinical trial

Introduction:  Direct laryngoscopy can be challenging in infants and neonates. Even with an optimal line of sight to the glottic opening, the viewing angle has been measured at 15°. The STORZ DCI video laryngoscope (Karl Storz, Tuttlingen, Germany) incorporates a fiberoptic camera in the light source of a standard laryngoscope of variable sizes. The image is displayed on a screen with a viewing angle of 80°. We studied the effectiveness of the STORZ DCI as an airway tool compared to standard direct laryngoscopy in children with normal airway.

[1]  L. Tiret,et al.  Complications related to anaesthesia in infants and children. A prospective survey of 40240 anaesthetics. , 1988, British journal of anaesthesia.

[2]  Marsha M. Cohen,et al.  Pediatric Anesthesia Morbidity and Mortality in the Perioperative Period , 1990, Anesthesia and analgesia.

[3]  G. Gregory,et al.  CLASSIFICATION AND ASSESSMENT OF THE DIFFICULT PEDIATRIC AIRWAY , 1998 .

[4]  M. Weiss,et al.  Teaching and supervising tracheal intubation in paediatric patients using videolaryngoscopy , 2001, Paediatric anaesthesia.

[5]  A. Brambrink,et al.  Management of the paediatric airway: new developments , 2002, Current opinion in anaesthesiology.

[6]  Chris Field,et al.  Laryngoscopic Intubation: Learning and Performance , 2003, Anesthesiology.

[7]  G. Berci,et al.  A New Video Laryngoscope - An Aid in Intubation and Teaching. , 2002, The journal of education in perioperative medicine : JEPM.

[8]  M. Wheeler Management strategies for the difficult pediatric airway. , 1998, Middle East journal of anaesthesiology.

[9]  C. Delhumeau,et al.  Incidence and risk factors of perioperative respiratory adverse events in children undergoing elective surgery , 2004, Paediatric anaesthesia.

[10]  K. Goldmann Recent developments in airway management of the paediatric patient , 2006, Current opinion in anaesthesiology.

[11]  George Berci,et al.  Comparison of direct and video-assisted views of the larynx during routine intubation. , 2006, Journal of clinical anesthesia.

[12]  H. Na,et al.  GlideScope video laryngoscope: a randomized clinical trial in 203 paediatric patients. , 2008, British journal of anaesthesia.

[13]  M. Passariello,et al.  Anesthesia for a child with deletion 3q syndrome , 2008, Paediatric anaesthesia.

[14]  H. Na,et al.  GlideScope w video laryngoscope : a randomized clinical trial in 203 paediatric patients † , 2008 .

[15]  S. Wald,et al.  Pediatric video laryngoscope rescue for a difficult neonatal intubation , 2008, Paediatric anaesthesia.

[16]  D. Healy,et al.  The use of the BERCI DCI® Video Laryngoscope for teaching novices direct laryngoscopy and tracheal intubation * , 2008, Anaesthesia.

[17]  Ranju Singh,et al.  A comparison of Truview infant EVO2 laryngoscope with the Miller blade in neonates and infants , 2009, Paediatric anaesthesia.

[18]  M. Bloch,et al.  Pediatric airway management: comparing the Berci–Kaplan Video Laryngoscope with direct laryngoscopy , 2009, Paediatric anaesthesia.