Micro gas turbine cogeneration system with latent heat storage at the University: Part III: Temperature control schedule

Abstract The latent heat storage system is a novel heat storage system. At the University under service conditions, it was demonstrated with a micro gas turbine (MGT) cogeneration system (CGS). Expanding the latent heat storage system into new applications is expected to save energy economically with high density energy storage and reduce exhaust emissions and reduce operational costs. This is the first demonstration of using a latent heat storage system with CGS under service condition and its characteristics are very important. In Part I, a fixed operating schedule of the system was planned and demonstrated at the University. The charge/discharge cycles of the latent heat storage system were repeated for 407 times. The energy flow test of the system shows the importance of the heat release source and total system design. In Part II, an irregular charge case of the latent heat storage system was discussed when the prime mover of the system was operated at a part load and thermal priority mode. A highly sophisticated system design that solves these problems was necessary for extending the applications of the latent heat storage system. In Part III, a temperature control schedule of the system was demonstrated during winter mornings using a new programmable logic controller (PLC). Using a fixed schedule, the MGT-CGS with latent heat storage reduced the CO2 emission when the energy utilization factor was above 50%. The temperature control schedule was considered to be better than the fixed schedule, both in terms of the operational efficiency of the overall system and CO2 reduction. The temperature control schedule was executed using an empirical formula for the temperature rise in a classroom. The restriction on the operation time by the contract with the gas supplier and the low heating capacity of the CGS affected the heating time and temperature rise. The temperature rise in the classroom was almost proportional to the integrated temperature difference across the hot water header of the heating system. On cold days, the rate of temperature rise produced by the CGS was very slow, therefore, additional heat supplied by the original boiler was used to increase the temperature rise. If larger latent heat storage systems will be developed in future, it will be expected that the temperature of the classrooms are kept more comfortable with less energy consumptions and lower CO2 emission.

[1]  Ryohei Yokoyama,et al.  Effect of power interchange operation of multiple household gas engine cogeneration systems on energy-saving , 2009 .

[2]  Asfaw Beyene,et al.  Thermoeconomic analysis of a cogeneration system of a university campus , 2002 .

[3]  Ibrahim Dincer,et al.  Efficiency analysis of a cogeneration and district energy system , 2005 .

[4]  Tong Seop Kim,et al.  The influence of water and steam injection on the performance of a recuperated cycle microturbine for combined heat and power application , 2010 .

[5]  Takayuki Matsunuma,et al.  Micro gas turbine cogeneration system with latent heat storage at the University: Part II: Part load and thermal priority mode , 2014 .

[6]  Takayuki Matsunuma,et al.  Start Time Control of Micro Gas Turbine CHP System With Heat Storage , 2011 .

[7]  Firdaus Basrawi,et al.  Effect of ambient temperature on the performance of micro gas turbine with cogeneration system in cold region , 2011 .

[8]  P. A. Pilavachi Mini- and micro-gas turbines for combined heat and power , 2002 .

[9]  Laura Vanoli,et al.  Micro-combined heat and power in residential and light commercial applications , 2003 .

[10]  M. A. Ehyaei,et al.  Energy, economic and environmental (3E) analysis of a micro gas turbine employed for on-site combined heat and power production , 2010 .

[11]  Takeo S. Saitoh,et al.  Performance of Supercooled Thermal Energy Storage Unit with Practical Dimensions , 2005 .

[12]  Luisa F. Cabeza,et al.  Review on thermal energy storage with phase change: materials, heat transfer analysis and applications , 2003 .

[13]  Takayuki Matsunuma,et al.  Micro gas turbine cogeneration system with latent heat storage at the University: Part I: Plan and energy flow test , 2014 .

[14]  V. I. Ugursal,et al.  Residential cogeneration systems: Review of the current technology , 2006 .

[15]  Masud Behnia,et al.  A study on the optimum arrangement of prime movers in small scale microturbine-based CHP systems , 2012 .

[16]  O. M. Al-Rabghi,et al.  Cogeneration with gas turbine engines , 1993 .

[17]  Bernd Thomas,et al.  Benchmark testing of Micro-CHP units , 2008 .

[18]  Mehdi Aghaei Meybodi,et al.  Modeling and economic analysis of gas engine heat pumps for residential and commercial buildings in various climate regions of Iran , 2010 .

[19]  Costanzo Di Perna,et al.  Analysis of electric and thermal seasonal performances of a residential microCHP unit , 2012 .

[20]  Hongbo Ren,et al.  Economic and environmental evaluation of micro CHP systems with different operating modes for residential buildings in Japan , 2010 .