CMS Level-1 Calorimeter Trigger Detailed Simulation
暂无分享,去创建一个
CMS level-1 calorimeter trigger simulation results are discussed. The simulation results are obtained using CMSIM version 111 program based on the GEANT simulation of the detector. These CMSIM results compare favorably to the results from our fast simulation program used in earlier studies. Both these results indicate that the rate requirements of the data acquisition system can be met with a reasonable safety factor of three while providing high efficiencies for high ET physics processes of interest to CMS. Electron Identification Card 160 MHz Point-to-point Backplane Receiver Card VME P r o c e s s o r M O N I T O R EI EI EI EI EI EI EI EI JS CC S P A R E Figure 1: CMS level-1 calorimeter regional trigger crate which houses eight Receiver and eight Electron Identification Cards that share data via the 160 MHz point-to-point links on the backplane. The Jet/Summary card at the center of the crate provides the crate output to the global level-1 calorimeter and muon trigger crates.