Four methods of measuring tidal volume during high-frequency oscillatory ventilation

Objective:Assess the accuracy of four different methods of measuring tidal volume during simulated high-frequency oscillatory ventilation. Design:In vitro study. Setting:Research laboratory. Subjects:Three differential pressure pneumotachometers, a modified Pitot tube, an ultrasound flowmeter, and an adult hot wire anemometer. Interventions:Each device was placed in series with a Sensormedics 3100B high-frequency ventilator and an 8.0-mm endotracheal tube attached to a 48.9-L plethysmograph. Inspiratory/expiratory ratio was fixed at 1:1 and mean airway pressure at 10 cm H2O. Tidal volumes were calculated at each combination of frequency (f: 3, 4, 6, 8, 10, 12 Hz) and pressure amplitude (ΔP: 30, 60, 90 cm H2O) by digital integration of the sampled flow signals from each device and compared with those calculated from pressure changes within the plethysmograph. The protocol was repeated after incorporation of frequency-specific calibrations to the flow-measuring algorithm of each device. The hot wire anemometer was further evaluated at Fio2 of 1.0, 37°C, 80% humidity, mean airway pressure of 20 cm H2O, and an inspiratory/expiratory ratio of 1:2. Measurements and Main Results:Tidal volumes were 36–305 mL. Bland-Altman analysis demonstrated that each device exhibited systematic bias before frequency-specific adjustment. After frequency-specific adjustment of the flow-measuring algorithm, the two most accurate and precise devices were the Hans Rudolph pneumotachometer, which exhibited a mean error of 0.2% (95% confidence interval, −3.0% to 3.4%), and the hot wire anemometer, which had a mean error of −1.1% (95% confidence interval, −5.5% to 3.3%). The hot wire anemometer remained accurate at Fio2 1.0, 37°C, 80% humidity, mean airway pressure of 20 cm H2O, and an inspiratory/expiratory ratio of 1:2. Conclusions:Tidal volume can be measured during high-frequency oscillatory ventilation using a variety of techniques. Frequency-specific calibration improves the accuracy and precision of tidal volume measurements. Hot wire anemometry exhibits stable performance characteristics across the range of temperature, humidity, Fio2, and inspiratory/expiratory ratios encountered clinically, has a small deadspace, is unaffected by mean airway pressure, and is therefore suitable for clinical applications.

[1]  David W. Kaczka,et al.  Assessment of time-domain analyses for estimation of low-frequency respiratory mechanical properties and impedance spectra , 1995, Annals of Biomedical Engineering.

[2]  Hannu Hänninen,et al.  A novel sensor for routine continuous spirometry of intubated patients , 1993, Journal of Clinical Monitoring.

[3]  Kenneth R. Lutchen,et al.  Servo-Controlled Pneumatic Pressure Oscillator for Respiratory Impedance Measurements and High-Frequency Ventilation , 2004, Annals of Biomedical Engineering.

[4]  J. P. Zock Linearity and frequency response of fleisch type pneumotachometers , 1981, Pflügers Archiv.

[5]  P. Rispens,et al.  Calculated changes in pH andpCO2 in arterial blood plasma assuming absence of ion and water exchange between plasma and erythrocytes during their equilibration with alveolar gas , 1981, Pflügers Archiv.

[6]  S. Derdak High-frequency oscillatory ventilation for acute respiratory distress syndrome in adult patients. , 2003, Critical care medicine.

[7]  R. Kacmarek,et al.  Determinants of tidal volume during high-frequency oscillation* , 2003, Critical care medicine.

[8]  Sangeeta Mehta,et al.  High-frequency oscillatory ventilation for acute respiratory distress syndrome in adults: a randomized, controlled trial. , 2002, American journal of respiratory and critical care medicine.

[9]  P. Sly,et al.  Reliable tidal volume estimates at the airway opening with an infant monitor during high-frequency oscillatory ventilation , 2001, Critical care medicine.

[10]  M. Wilkinson,et al.  In vitro performance characteristics of high-frequency oscillatory ventilators. , 2001, American journal of respiratory and critical care medicine.

[11]  S. Lapinsky,et al.  Prospective trial of high-frequency oscillation in adults with acute respiratory distress syndrome , 2001, Critical care medicine.

[12]  D. Schoenfeld,et al.  Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. , 2000, The New England journal of medicine.

[13]  A. Froese,et al.  Mechanical performance of clinically available, neonatal, high-frequency, oscillatory-type ventilators. , 1998, Critical care medicine.

[14]  G. Dimitriou,et al.  Volume delivery during high frequency oscillation , 1998, Archives of disease in childhood. Fetal and neonatal edition.

[15]  C. Carvalho,et al.  Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome. , 1998, The New England journal of medicine.

[16]  A. Froese High-frequency oscillatory ventilation for adult respiratory distress syndrome: let's get it right this time! , 1997, Critical care medicine.

[17]  W. Beninati,et al.  HIGH FREQUENCY OSCILLATORY VENTILATION FOR ADULT RESPIRATORY DISTRESS SYNDROME‐A PILOT STUDY , 1995, Critical care medicine.

[18]  J. Stocks,et al.  In vitro assessment of infant pulmonary function equipment , 1995, Pediatric pulmonology.

[19]  B. Foitzik,et al.  Einfluß der physikalischen Eigenschaften des Atemgases auf die pneumotachographische Ventilationsmessung bei Neugeborenen - Effect of the Physical Properties of Respiratory Gas on Pneumotachographic Measurement of Ventilation in Neonates , 1994 .

[20]  B Foitzik,et al.  [Effect of physical properties of respiratory gas on pneumotachographic measurement of ventilation in newborn infants]. , 1994, Biomedizinische Technik. Biomedical engineering.

[21]  A. Milner,et al.  The effect of frequency and mean airway pressure on volume delivery during high‐frequency oscillation , 1993, Pediatric Pulmonology.

[22]  E. W. Hoskyns,et al.  Measurement of tidal lung volumes in neonates during high-frequency oscillation. , 1992, Journal of Biomedical Engineering.

[23]  B.A. Simon,et al.  Design and calibration of a high-frequency oscillatory ventilator , 1991, IEEE Transactions on Biomedical Engineering.

[24]  S. Courtney,et al.  Measurement of tidal volume using a pneumotachometer during high-frequency oscillation. , 1990, Critical care medicine.

[25]  Karen S. Adams,et al.  Comparison of Conventional Mechanical Ventilation and High‐frequency Ventilation: A Prospective, Randomized Trial in Patients with Respiratory Failure , 1990, Annals of surgery.

[26]  W. Guggenbühl,et al.  A pulsed diagonal-beam ultrasonic airflow meter. , 1986, Journal of applied physiology.

[27]  R. Cotton,et al.  Measurement of Tidal Volume during High Frequency Ventilation by Impedance Plethysmography , 1988, Pediatric Research.

[28]  R B Smith,et al.  High frequency ventilation. , 1988, International anesthesiology clinics.

[29]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[30]  J. M. Fouke,et al.  Measurement of Tidal Volume during High- Frequency Jet Ventilation1 , 1986, Pediatric Research.

[31]  R. Peslin,et al.  In-phase rejection requirements for measuring respiratory input impedance. , 1984, Journal of applied physiology: respiratory, environmental and exercise physiology.

[32]  G. Carlon,et al.  High-Frequency Jet Ventilation: A Prospective Randomized Evaluation , 1983 .

[33]  R. Gelfand,et al.  Effects of gas density on the frequency response of gas-filled pressure transducers. , 1979, Journal of applied physiology: respiratory, environmental and exercise physiology.

[34]  F. E. Jørgensen,et al.  A New Transducer for Respiratory Monitoring: A Description of a Hot‐wire Anemometer and a Test Procedure for General Use , 1979, Acta Anaesthesiologica Scandinavica.

[35]  A Vinegar,et al.  A technique for measuring frequency response of pressure, volume, and flow transducers. , 1979, Journal of applied physiology: respiratory, environmental and exercise physiology.

[36]  S V Dawson,et al.  Linearity and frequency response of pneumotachographs. , 1972, Journal of applied physiology.

[37]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.