Microfluidic chip-based liquid-liquid extraction and preconcentration using a subnanoliter-droplet trapping technique.

A robust and simple approach for microfluidic liquid-liquid (L-L) extraction at the subnanoliter-scale was developed for on-chip sample pretreatment. Organic solvent droplets of a few hundred pL were trapped within micro recesses fabricated in the channel walls of a microfabricated glass chip. L-L extraction was performed by delivering aqueous samples through the channel, with the sample stream continuously flowing adjacent to the droplets. The analytes in aqueous streams were enriched within the droplet with high preconcentration factors owing to both phase transfer and dissolution of organic solvent into the bypassing aqueous sample. An aqueous solution of butyl rhodamine B (BRB) and 1-hexanol were used, respectively, as sample and extractant to demonstrate the performance of the system. The fluorescence intensity of the dye extracted into the droplet was monitored in situ by LIF. The system proved to be an efficient means for achieving high enrichment factors of over 1000, with sample consumption of a few microL. Quantitative measurement of the extracted analyte was achieved with a linear response in the range 1 x 10(-9)-8 x 10(-7) M BRB. The precision of the measured fluorescence values for a 10(-7) M BRB standard with a 12.5 min preconcentration period was 6.6% RSD (n = 5).

[1]  Takehiko Kitamori,et al.  Three-layer flow membrane system on a microchip for investigation of molecular transport. , 2002, Analytical chemistry.

[2]  Morita,et al.  Investigation of the molecular extraction process in single subpicoliter droplets using a near-infrared laser Raman trapping system , 2000, Analytical chemistry.

[3]  M. Tokeshi,et al.  Integration of a microextraction system on a glass chip: ion-pair solvent extraction of Fe(II) with 4,7-diphenyl-1,10-phenanthrolinedisulfonic acid and tri-n-octylmethylammonium chloride , 2000, Analytical chemistry.

[4]  N. Kitamura,et al.  Microinjection-microspectroscopy of single oil droplets in water: an application to liquid/liquid extraction under solution-flow conditions , 2000 .

[5]  N. Kalogerakis,et al.  Application of solvent microextraction to the analysis of nitroaromatic explosives in water samples. , 2001, Journal of chromatography. A.

[6]  Q. Fang,et al.  A high-throughput continuous sample introduction interface for microfluidic chip-based capillary electrophoresis systems. , 2002, Analytical chemistry.

[7]  L. D. de Jager,et al.  Development of a screening method for cocaine and cocaine metabolites in urine using solvent microextraction in conjunction with gas chromatography. , 2001, Journal of chromatography. A.

[8]  F. Cantwell,et al.  Solvent Microextraction with Simultaneous Back-Extraction for Sample Cleanup and Preconcentration: Preconcentration into a Single Microdrop , 1999 .

[9]  Hian Kee Lee,et al.  Liquid-Phase Microextraction in a Single Drop of Organic Solvent by Using a Conventional Microsyringe , 1997 .

[10]  M. Jeannot,et al.  Solvent microextraction as a speciation tool: determination of free progesterone in a protein solution. , 1997, Analytical chemistry.

[11]  Jingtian Hu,et al.  Use of ionic liquids for liquid-phase microextraction of polycyclic aromatic hydrocarbons. , 2003, Analytical chemistry.

[12]  P. Dasgupta,et al.  Analytical chemistry in a drop. Solvent extraction in a microdrop. , 1996, Analytical chemistry.

[13]  Takehiko Kitamori,et al.  Stabilization of liquid interface and control of two-phase confluence and separation in glass microchips by utilizing octadecylsilane modification of microchannels. , 2002, Analytical chemistry.

[14]  D. Chiu,et al.  Concentrating solutes and nanoparticles within individual aqueous microdroplets. , 2004, Analytical chemistry.

[15]  B. Keller,et al.  Nanoliter solvent extraction combined with microspot MALDI TOF mass spectrometry for the analysis of hydrophobic biomolecules. , 2001, Analytical chemistry.

[16]  Liu,et al.  Continuous-flow microextraction exceeding 1000-fold concentration of dilute analytes , 2000, Analytical chemistry.

[17]  Takehiko Kitamori,et al.  On-Chip Integration of Neutral Ionophore-Based Ion Pair Extraction Reaction , 2001 .

[18]  N. Kalogerakis,et al.  Developments in single-drop microextraction , 2002 .

[19]  F. Cantwell,et al.  Mass Transfer Characteristics of Solvent Extraction into a Single Drop at the Tip of a Syringe Needle , 1997 .

[20]  Y. Wang,et al.  Application of dynamic liquid-phase microextraction to the analysis of chlorobenzenes in water by using a conventional microsyringe. , 1998, Analytical chemistry.