Disposable liposome immunosensor for theophylline combining an immunochromatographic membrane and a thick-film electrode

Abstract A novel electrochemical immunosensor based on the principles of liposome signal amplification and immunochromatography has been developed for the determination of theophylline. The immunosensor is composed of two major parts including a screen-printed electrode and an immunochromatographic nitrocellulose membrane strip. On the membrane, anti-theophylline antibody is immobilized in an antibody competition zone and hexacyanoferrate(II)-loaded liposomes are immobilized in a signal generation zone. When a theophylline sample solution is applied to the immunosensor pre-loaded with theophylline–melittin conjugate in sample loading zone, the theophylline and theophylline–melittin conjugate migrate through the anti-theophylline antibody zone, where competitive binding occurs. Unbound theophylline–melittin conjugate further migrates into the signal generation zone, where it disrupts the liposomes to release the electroactive hexacyanoferrate(II) which is then detected amperometrically. The current produced is directly proportional to the concentration of hexacyanoferrate(II) which, in turn, can be related to the concentration of free analyte in the sample. The detection limit of 5 μg ml −1 enables the present immunosensor to be used to monitor theophylline over the clinically relevant ranges (10–20 μg ml −1 ) with a one-step assay within 20 min.

[1]  Richard A. Durst,et al.  Liposome immunomigration field assay device for Alachlor determination , 1993 .

[2]  M. Haga,et al.  Drug sensor: liposome immunosensor for theophylline. , 1981, Analytical biochemistry.

[3]  M. Roberts,et al.  Improved liposome immunomigration strip assay for alachlor determination , 1995 .

[4]  R A Durst,et al.  Investigation of liposome-based immunomigration sensors for the detection of polychlorinated biphenyls. , 1995, Analytical chemistry.

[5]  S. Higson,et al.  The characterization of liposomal glucose oxidase electrodes for the measurement of glucose. , 1995, Biosensors & bioelectronics.

[6]  J. Park,et al.  AMPEROMETRIC BIOSENSOR FOR DETERMINATION OF ETHANOL VAPOR , 1995 .

[7]  R A Durst,et al.  Liposome flow injection immunoassay: implications for sensitivity, dynamic range, and antibody regeneration. , 1990, Analytical chemistry.

[8]  R. Schmid,et al.  Liposome-based immunosensors. 1. Influence of hapten spacer length on liposome binding efficiency , 1996 .

[9]  M. Haga,et al.  Liposome immunosensor for theophylline. , 1980, Biochemical and Biophysical Research Communications - BBRC.

[10]  P. D'Orazio,et al.  Ion electrode measurements of complement and antibody levels using marker-loaded sheep red blood cell ghosts. , 1977, Analytical chemistry.

[11]  E. F. Ullman,et al.  Enzyme immunochromatography--a quantitative immunoassay requiring no instrumentation. , 1985, Clinical chemistry.

[12]  S. Yoshikawa,et al.  Peroxidase-dependent fluorescence decrease of carboxyfluorescein and its enhancement by liposome encapsulation , 1995 .

[13]  W. J. Litchfield,et al.  Highly sensitive immunoassays based on use of liposomes without complement. , 1984, Clinical chemistry.

[14]  R. New,et al.  Liposomes : a practical approach , 1990 .

[15]  R. Durst,et al.  Novel Optical Measurement Approach for the Quantitation of Liposome Immunomigration Assays , 1995 .

[16]  M. Roberts,et al.  Flow-injection liposome immunoanalysis (FILIA) for alachlor. , 1994, Talanta.

[17]  K. Park,et al.  Liposome immunoassay (LIA) for gentamicin using phospholipase C. , 1994, Journal of immunological methods.

[18]  M. Haga,et al.  An improved chemiluminescence-based liposome immunoassay involving apoenzyme. , 1990, Chemical & pharmaceutical bulletin.

[19]  R Chen,et al.  An internal clock reaction used in a one-step enzyme immunochromatographic assay of theophylline in whole blood. , 1987, Clinical chemistry.

[20]  R. Durst,et al.  Flow-injection liposome immunoanalysis (FILIA) with electrochemical detection , 1995 .

[21]  T. Wink,et al.  Liposome-mediated enhancement of the sensitivity in immunoassays of proteins and peptides in surface plasmon resonance spectrometry. , 1998, Analytical chemistry.

[22]  W. P. Bennekom,et al.  Development of a liposome immunosorbent assay for human interferon-y , 1994 .

[23]  Richard A. Durst,et al.  Comparison of liposome amplification and fluorophor detection in flow-injection immunoanalyses , 1997 .

[24]  Y. Umezawa,et al.  Thin-layer potentiometric analysis of lipid antigen-antibody reaction by tetrapentylammonium (TPA+) ion loaded liposomes and TPA+ ion selective electrode. , 1980, Analytical chemistry.

[25]  Gregory Gregoriadis,et al.  Liposomes for drugs and vaccines , 1985 .

[26]  W. J. Litchfield,et al.  Liposome-mediated immunoassays for small haptens (digoxin) independent of complement. , 1984, Journal of immunological methods.

[27]  A. Tanaka,et al.  An immunochemical study with potassium ion-loaded liposomes. , 1982, Chemical & pharmaceutical bulletin.