In vivo corneal endothelium imaging using ultrahigh resolution OCT.

We investigate the influence of optical coherence tomography (OCT) system resolution on high-quality in vivo en face corneal endothelial cell images of the monkey eye, to allow for quantitative analysis of cell density. We vary the lateral resolution of the ultrahigh resolution (UHR) OCT system (centered at 850 nm) by using different objectives, and the axial resolution by windowing the source spectrum. By suppressing the motion of the animal, we are able to obtain a high-quality en face corneal endothelial cell map in vivo using UHR OCT for the first time with a lateral resolution of 3.1 µm. Increasing lateral resolution did not result in a better image quality but a smaller field of view (FOV), and the axial resolution had little impact on the visualization of corneal endothelial cells. Quantitative analysis of cell density was performed on in vivo en face OCT images of corneal endothelial cells, and the results are in agreement with previously reported data. Our study may offer a practical guideline for designing OCT systems that allow for in vivo corneal endothelial cell imaging with high quality.

[1]  Robert J Zawadzki,et al.  Review of adaptive optics OCT (AO-OCT): principles and applications for retinal imaging [Invited]. , 2017, Biomedical optics express.

[2]  Wolfgang Drexler,et al.  Numerical focusing methods for full field OCT: a comparison based on a common signal model. , 2014, Optics express.

[3]  Angelika Unterhuber,et al.  Ultrahigh‐resolution anterior segment optical coherence tomography for analysis of corneal microarchitecture during wound healing , 2019, Acta ophthalmologica.

[4]  M. Fink,et al.  In vivo high resolution human corneal imaging using full-field optical coherence tomography. , 2018, Biomedical optics express.

[5]  Linbo Liu,et al.  Evaluation of a Micro-Optical Coherence Tomography for the Corneal Endothelium in an Animal Model , 2016, Scientific Reports.

[6]  Patrice Tankam,et al.  Capabilities of Gabor-domain optical coherence microscopy for the assessment of corneal disease , 2019, Journal of biomedical optics.

[7]  M. Ang,et al.  Descemet Membrane Endothelial Keratoplasty versus Descemet Stripping Automated Endothelial Keratoplasty and Penetrating Keratoplasty. , 2019, American journal of ophthalmology.

[8]  Marcus Ang,et al.  Descemet membrane endothelial keratoplasty , 2015, British Journal of Ophthalmology.

[9]  Kostadinka Bizheva,et al.  In-vivo imaging of the palisades of Vogt and the limbal crypts with sub-micrometer axial resolution optical coherence tomography. , 2017, Biomedical optics express.

[10]  Benjamin J Vakoc,et al.  Phase-stable Doppler OCT at 19 MHz using a stretched-pulse mode-locked laser. , 2018, Biomedical optics express.

[11]  Cris L. Luengo Hendriks,et al.  Fully automatic evaluation of the corneal endothelium from in vivo confocal microscopy , 2015, BMC Medical Imaging.

[12]  A. Ruggeri,et al.  A new system for the automatic estimation of endothelial cell density in donor corneas , 2005, British Journal of Ophthalmology.

[13]  H E Kaufman,et al.  Specular microscopy of human corneal endothelium in vivo. , 1976, American journal of ophthalmology.

[14]  Kostadinka Bizheva,et al.  250 kHz, 1.5 µm resolution SD-OCT for in-vivo cellular imaging of the human cornea. , 2018, Biomedical optics express.

[15]  Kostadinka Bizheva,et al.  Sub-micrometer axial resolution OCT for in-vivo imaging of the cellular structure of healthy and keratoconic human corneas. , 2017, Biomedical optics express.

[16]  M. Foracchia,et al.  Automatic estimation of endothelium cell density in donor corneas by means of Fourier analysis , 2004, Medical and Biological Engineering and Computing.

[17]  O Stachs,et al.  In vivo three-dimensional confocal laser scanning microscopy of corneal surface and epithelium , 2008, British Journal of Ophthalmology.

[18]  Wolfgang Wieser,et al.  Live video rate volumetric OCT imaging of the retina with multi-MHz A-scan rates , 2019, PloS one.

[19]  Angelika Unterhuber,et al.  In vivo tear film thickness measurement and tear film dynamics visualization using spectral domain optical coherence tomography. , 2015, Optics express.

[20]  R J Buckley,et al.  Fourier transform analysis of human corneal endothelial specular photomicrographs. , 1997, Experimental eye research.

[21]  Leopold Schmetterer,et al.  Anterior segment optical coherence tomography , 2018, Progress in Retinal and Eye Research.

[22]  Marcus Ang,et al.  Endothelial cell loss and graft survival after Descemet's stripping automated endothelial keratoplasty and penetrating keratoplasty. , 2012, Ophthalmology.

[23]  Pedram Hamrah,et al.  In Vivo Confocal Microscopy of the Ocular Surface: From Bench to Bedside , 2014, Current eye research.

[24]  R. Chuck,et al.  Keratoplasty in the United States: A 10-Year Review from 2005 through 2014. , 2015, Ophthalmology.

[25]  L. Schmetterer,et al.  Ultrahigh-resolution OCT imaging of the human cornea. , 2017, Biomedical optics express.

[26]  M. Sherwood,et al.  Corneal thickness and endothelial cell density measured by non-contact specular microscopy and pachymetry in Rhesus macaques (Macaca mulatta) with laser-induced ocular hypertension. , 2003, Experimental eye research.