Increasing the field of view of x-ray phase contrast imaging using stitched gratings on low absorbent carriers

X-ray phase contrast imaging has become a promising biomedical imaging technique for enhancing soft-tissue contrast. In addition to an absorption contrast image it provides two more types of image, a phase contrast and a small-angle scattering contrast image recorded at the same time. In biomedical imaging their combination allows for the conventional investigation of e.g. bone fractures on the one hand and for soft-tissue investigation like cancer detection on the other hand. Among the different methods of X-ray phase contrast imaging the grating based approach, the Talbot-Lau interferometry, has the highest potential for commercial use in biomedical imaging at the moment, because commercially available X-ray sources can be used in a compact setup. In Talbot-Lau interferometers, core elements are phase and absorption gratings with challenging specifications because of their high aspect ratios (structure height over width). For the long grating lamellas structural heights of more than 100 μm together with structural width in the micron range are requested. We are developing a fabrication process based on deep x-ray lithography and electroforming (LIGA) to fabricate these challenging structures. In case of LIGA gratings the structural area is currently limited to several centimeters by several centimeters which limit the field of view in grating based X-ray phase contrast imaging. In order to increase the grating area significantly we are developing a stitching method for gratings using a 625 μm thick silicon wafer as a carrier substrate. In this work we compare the silicon carrier with an alternative one, polyimide, for patient dose reduction and for the use at lower energies in terms of transmission and image reconstruction problems.

[1]  T Takeda,et al.  Blood vessels: depiction at phase-contrast X-ray imaging without contrast agents in the mouse and rat-feasibility study. , 2000, Radiology.

[2]  Patrik Vagovič,et al.  X-ray phase-contrast radiography using a filtered white beam with a grating interferometer , 2011 .

[3]  Fabian Bamberg,et al.  Characterization of Osteoarthritic and Normal Human Patella Cartilage by Computed Tomography X-ray Phase-Contrast Imaging: A Feasibility Study , 2010, Investigative radiology.

[4]  Johannes Kenntner,et al.  Fabrication and characterization of analyzer gratings with high aspect ratios for phase contrast imaging using a Talbot interferometer , 2012 .

[5]  Marcus Radicke,et al.  Grating-based darkfield imaging of human breast tissue. , 2013, Zeitschrift fur medizinische Physik.

[6]  Franz Pfeiffer,et al.  Quantitative X-ray phase-contrast computed tomography at 82 keV. , 2013, Optics express.

[7]  Yi Qin,et al.  Micromanufacturing Engineering and Technology , 2015 .

[8]  Juerg Leuthold,et al.  High aspect ratio gratings for X-ray phase contrast imaging , 2012 .

[9]  Richard J. Fitzgerald,et al.  Phase‐Sensitive X‐Ray Imaging , 2000 .

[10]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[11]  Gilles Peix,et al.  Hard x-ray phase imaging using simple propagation of a coherent synchrotron radiation beam , 1999 .

[12]  Franz Pfeiffer,et al.  Grating-based X-ray phase-contrast tomography of atherosclerotic plaque at high photon energies. , 2013, Zeitschrift fur medizinische Physik.

[13]  Franz Pfeiffer,et al.  Toward Clinical X-ray Phase-Contrast CT , 2010 .

[14]  Juergen Mohr,et al.  Soft X-ray lithography of high aspect ratio SU8 submicron structures , 2008 .

[15]  Atsushi Momose,et al.  Demonstration of phase-contrast X-ray computed tomography using an X-ray interferometer , 1995 .

[16]  S. Wilkins,et al.  Phase-contrast imaging using polychromatic hard X-rays , 1996, Nature.

[17]  Franz Pfeiffer,et al.  Experimental results from a preclinical X-ray phase-contrast CT scanner , 2012, Proceedings of the National Academy of Sciences.

[18]  Franz Pfeiffer,et al.  Toward Clinical X-ray Phase-Contrast CT: Demonstration of Enhanced Soft-Tissue Contrast in Human Specimen , 2010, Investigative radiology.

[19]  Franz Pfeiffer,et al.  X-ray phase imaging with a grating interferometer. , 2005, Optics express.

[20]  W. Menz,et al.  Silicon Microsystem Technology , 2007 .

[21]  Franz Pfeiffer,et al.  Soft-tissue phase-contrast tomography with an x-ray tube source , 2009, Physics in medicine and biology.

[22]  Franz Pfeiffer,et al.  High-resolution tomographic imaging of a human cerebellum: comparison of absorption and grating-based phase contrast , 2010, Journal of The Royal Society Interface.