Standing-up exerciser based on functional electrical stimulation and body weight relief

The goal of the present work was to develop and test an innovative system for the training of paraplegic patients when they are standing up. The system consisted of a computer-controlled stimulator, surface electrodes for quadricep muscle stimulation, two knee angle sensors, a digital proportional-integrative-derivative (PID) controller and a mechanical device to support, partially, the body weight (weight reliever (WR)). A biomechanical model of the combined WR and patient was developed to find an optimum reference trajectory for the PID controller. The system was tested on three paraplegic patients and was shown to be reliable and safe. One patient completed a 30-session training period. Initially he was able to stand up only with 62% body weight relief, whereas, after the training period, he performed a series of 30 standing-up/sitting-down cycles with 45% body weight relief. The closed-loop controller was able to keep the patient standing upright with minimum stimulation current, to compensate automatically for muscle fatigue and to smooth the sitting-down movement. The limitations of the controller in connection with a highly nonlinear system are considered.

[1]  H. Schwan,et al.  Biological Engineering , 1970 .

[2]  D. Rushton,et al.  Electrical splinting of the knee in paraplegia , 1979, Paraplegia.

[3]  T Bajd,et al.  Use of a two-channel functional electrical stimulator to stand paraplegic patients. , 1981, Physical therapy.

[4]  T Bajd,et al.  Standing-up of a healthy subject and a paraplegic patient. , 1982, Journal of biomechanics.

[5]  Vladimir M. Zatsiorsky,et al.  The Mass and Inertia Characteristics of the Main Segments of the Human Body , 1983 .

[6]  J S Petrofsky,et al.  Feedback control system for walking in man. , 1984, Computers in biology and medicine.

[7]  Chandler A. Phillips,et al.  Bicycle Ergometer For Paralyzed Muscle , 1984 .

[8]  D J Ewins,et al.  Practical low cost stand/sit system for mid-thoracic paraplegics. , 1988, Journal of biomedical engineering.

[9]  A. Kralj,et al.  Functional Electrical Stimulation: Standing and Walking after Spinal Cord Injury , 1989 .

[10]  R. D'ambrosia,et al.  The RGO Generation II: muscle stimulation powered orthosis as a practical walking system for thoracic paraplegics. , 1989, Orthopedics.

[11]  J. Quintern,et al.  Functional neuromuscular stimulation for standing after spinal cord injury. , 1990, Archives of physical medicine and rehabilitation.

[12]  Robertw . Mann,et al.  Mechanics of a constrained chair-rise. , 1991, Journal of biomechanics.

[13]  Adaptive control of functional neuromuscular stimulation-induced knee extension exercise. , 1991, Journal of rehabilitation research and development.

[14]  M A Hughes,et al.  Chair rise strategies in the elderly. , 1994, Clinical biomechanics.

[15]  Ja White,et al.  Standardization and definitions of the sit-stand-sit movement cycle , 1994 .

[16]  R. M. Glaser,et al.  Functional Neuromuscular Stimulation , 1994, International journal of sports medicine.

[17]  R. M. Glaser,et al.  Tibial bone density loss in spinal cord injured patients: effects of FES exercise. , 1994, Journal of rehabilitation research and development.

[18]  V. Dietz,et al.  Locomotor capacity of spinal cord in paraplegic patients , 1995, Annals of neurology.

[19]  N de N Donaldson,et al.  FES standing: control by handle reactions of leg muscle stimulation (CHRELMS). , 1996, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[20]  M. Ferrarin,et al.  An experimental PID controller for knee movement restoration with closed loop FES system , 1996, Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[21]  M. Ferrarin,et al.  A New Biomechanical Approach to Pendulum Test for Spasticity Evaluation , 1996 .

[22]  R. D'ambrosia,et al.  Reciprocating gait orthosis powered with electrical muscle stimulation (RGO II). Part II: Medical evaluation of 70 paraplegic patients. , 1997, Orthopedics.

[23]  R. D'ambrosia,et al.  Reciprocating gait orthosis powered with electrical muscle stimulation (RGO II). Part I: Performance evaluation of 70 paraplegic patients. , 1997, Orthopedics.

[24]  R Riener,et al.  Patient-driven control of FES-supported standing up: a simulation study. , 1998, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[25]  P.H. Veltink,et al.  A Perspective On The Control Of FES-supported Standing , 1998, IEEE Transactions on Rehabilitation Engineering.

[26]  A Pedotti,et al.  Paraplegic adaptation to assisted-walking: energy expenditure during wheelchair versus orthosis use , 2000, Spinal Cord.

[27]  R Riener,et al.  Patient-driven control of FES-supported standing up and sitting down: experimental results. , 2000, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[28]  R Triolo,et al.  Functional neuromuscular stimulation in spinal cord injury. , 2000, Physical medicine and rehabilitation clinics of North America.

[29]  T. Perkins,et al.  FES cycling may promote recovery of leg function after incomplete spinal cord injury , 2000, Spinal Cord.

[30]  R. Riener,et al.  Model-based control of FES-induced single joint movements , 2001, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[31]  Leg exerciser for training of paralysed muscle by closed-loop control , 1984, Medical and Biological Engineering and Computing.