The role of innovative modeling and imaging techniques in improving outcomes in patients with LVAD

Heart failure remains a significant cause of mortality in the United States and around the world. While organ transplantation is acknowledged as the gold standard treatment for end stage heart failure, supply is limited, and many patients are treated with left ventricular assist devices (LVADs). LVADs extend and improve patients' lives, but they are not without their own complications, particularly the hemocompatibility related adverse events (HRAE) including stroke, bleeding and pump thrombosis. Mainstream imaging techniques currently in use to assess appropriate device function and troubleshoot complications, such as echocardiography and cardiac computed tomography, provide some insight but do not provide a holistic understanding of pump induced flow alterations that leads to HRAEs. In contrast, there are technologies restricted to the benchtop—such as computational fluid dynamics and mock circulatory loops paired with methods like particle image velocimetry—that can assess flow metrics but have not been optimized for clinical care. In this review, we outline the potential role and current limitations of converging available technologies to produce novel imaging techniques, and the potential utility in evaluating hemodynamic flow to determine whether LVAD patients may be at higher risk of HRAEs. This addition to diagnostic and monitoring capabilities could improve prevention and treatment of LVAD-induced complications in heart failure patients.

[1]  Wenjun Wang,et al.  The effect of terminal impedance on aortic morphology and hemodynamics: an in vitro phantom study using flow field visualization , 2023, Frontiers in Bioengineering and Biotechnology.

[2]  S. Little,et al.  Patient-specific, echocardiography compatible flow loop model of aortic valve regurgitation in the setting of a mechanical assist device , 2023, Frontiers in Cardiovascular Medicine.

[3]  S. Bokhari,et al.  Effect of Left Ventricular Unloading by Pump Speed Adjustment on Myocardial Flow in Continuous-flow Left Ventricular Assist Device Patients , 2022, ASAIO journal.

[4]  S. Avril,et al.  A Hybrid Mock Circulatory Loop for Fluid Dynamic Characterization of 3D Anatomical Phantoms , 2022, IEEE Transactions on Biomedical Engineering.

[5]  R. Dowling,et al.  COMPETENCE Trial: The EVAHEART 2 continuous flow left ventricular assist device. , 2022, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[6]  N. Uriel,et al.  Five-Year Outcomes in Patients With Fully Magnetically Levitated vs Axial-Flow Left Ventricular Assist Devices in the MOMENTUM 3 Randomized Trial. , 2022, JAMA.

[7]  S. Grieve,et al.  The health digital twin to tackle cardiovascular disease—a review of an emerging interdisciplinary field , 2022, npj Digital Medicine.

[8]  H. Lamecker,et al.  CT-Based Analysis of Left Ventricular Hemodynamics Using Statistical Shape Modeling and Computational Fluid Dynamics , 2022, Frontiers in Cardiovascular Medicine.

[9]  J. Voorneveld,et al.  Left ventricular high frame rate echo-particle image velocimetry: clinical application and comparison with conventional imaging , 2022, Cardiovascular Ultrasound.

[10]  E. Potapov,et al.  Cardiac remodeling in patients with centrifugal left ventricular assist devices assessed by serial echocardiography , 2022, Echocardiography.

[11]  A. Piłat,et al.  Echo-guided left ventricular assist device speed optimisation for exercise maximisation , 2022, Heart.

[12]  J. Cowger,et al.  Trends and Outcomes of Left Ventricular Assist Device Therapy: JACC Focus Seminar. , 2022, Journal of the American College of Cardiology.

[13]  M. Walter,et al.  Hemolytic Performance in Two Generations of the Sputnik Left Ventricular Assist Device: A Combined Numerical and Experimental Study , 2022, Journal of functional biomaterials.

[14]  G. Sayer,et al.  Development of De Novo Aortic Insufficiency in Patients with HeartMate 3. , 2021, The Annals of thoracic surgery.

[15]  S. Leonhardt,et al.  Flow profile generation for a left ventricular assist device using iterative learning control , 2021, Current Directions in Biomedical Engineering.

[16]  J. Shields,et al.  The Clinical Application of Augmented Reality in Orthopaedics: Where Do We Stand? , 2021, Current Reviews in Musculoskeletal Medicine.

[17]  G. Sayer,et al.  The Role of Serial Right Heart Catheterization Survey in Patients Awaiting Heart Transplant on Ventricular Assist Device , 2021, ASAIO journal (1992).

[18]  K. Zhigalov,et al.  Virtual and Augmented Reality in Cardiac Surgery , 2021, Brazilian journal of cardiovascular surgery.

[19]  V. Roger Epidemiology of Heart Failure , 2021, Circulation research.

[20]  A. Kassab,et al.  Computational Fluid Dynamics Study of Cerebral Thromboembolism Risk in Ventricular Assist Device Patients: Effects of Pulsatility and Thrombus Origin. , 2021, Journal of biomechanical engineering.

[21]  E. Ashley,et al.  Cardiopulmonary Exercise Testing With Echocardiography to Assess Recovery in Patients With Ventricular Assist Devices , 2021, ASAIO journal.

[22]  F. Pagani,et al.  Fate of preoperative moderate mitral regurgitation following left ventricular assist device implantation , 2021, Journal of cardiac surgery.

[23]  Gene Kim,et al.  A New Strategy for Left Ventricular Assist Device Outflow Graft Interrogation Using Ultrasound Contrast. , 2020, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[24]  K. Caliskan,et al.  Evaluation of patients with a HeartMate 3 left ventricular assist device using echocardiographic particle image velocimetry , 2020, Journal of Ultrasound.

[25]  Rachelle N. Palchesko,et al.  FRESH 3D Bioprinting a Full-Size Model of the Human Heart. , 2020, ACS biomaterials science & engineering.

[26]  Manavotam Singh,et al.  Ventricular fibrillation in a left ventricular assist device patient: Can the echocardiogram be misleading? , 2020, Journal of cardiovascular electrophysiology.

[27]  T. Imamura,et al.  Aortic Insufficiency during HeartMate 3 Left Ventricular Assist Device Support: AI in HeartMate 3. , 2020, Journal of cardiac failure.

[28]  A. Marsden,et al.  Use of patient-specific computational models for optimization of aortic insufficiency after implantation of left ventricular assist device. , 2020, The Journal of thoracic and cardiovascular surgery.

[29]  V. Murthy,et al.  Diagnostic Accuracy of FDG PET/CT in Suspected LVAD Infections: A Case Series, Systematic Review, and Meta-Analysis. , 2020, JACC. Cardiovascular imaging.

[30]  S. Little,et al.  Proof of Concept: Echo Compatible Mock-Circulatory Flow Loop to Accurately Quantify Aortic Regurgitation in Patients with Left Ventricular Assist Devices. , 2020, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[31]  Kiyotaka Fukamachi,et al.  Use of a Virtual Mock Loop model to evaluate a new left ventricular assist device for transapical insertion , 2020, The International journal of artificial organs.

[32]  L. Lund,et al.  Validation of non‐invasive ramp testing for HeartMate 3 , 2020, ESC heart failure.

[33]  K. Caliskan,et al.  Transhepatic echocardiography: a novel approach for imaging in left ventricle assist device patients with difficult acoustic windows , 2020, European heart journal cardiovascular Imaging.

[34]  Heinrich Schima,et al.  Validation of numerically simulated ventricular flow patterns during left ventricular assist device support , 2020, The International journal of artificial organs.

[35]  I. Wamala,et al.  Computed Tomography and Fluoroscopic Angiography in Management of Left Ventricular Assist Device Outflow Graft Obstruction. , 2020, JACC. Cardiovascular imaging.

[36]  K. Fraser,et al.  Ventricular Flow Field Visualization During Mechanical Circulatory Support in the Assisted Isolated Beating Heart , 2019, Annals of Biomedical Engineering.

[37]  M. Balkanay,et al.  Outflow graft twisting of Heartmate III left ventricular-assisted device: A case report. , 2019, Turk gogus kalp damar cerrahisi dergisi.

[38]  Dmitry Telyshev,et al.  Numerical modeling of continuous-flow left ventricular assist device performance , 2019, The International journal of artificial organs.

[39]  H. Yalcin,et al.  Adaptation of a Mice Doppler Echocardiography Platform to Measure Cardiac Flow Velocities for Embryonic Chicken and Adult Zebrafish , 2019, Front. Bioeng. Biotechnol..

[40]  D. Burkhoff,et al.  Impact of Hemodynamic Ramp Test-Guided HVAD Speed and Medication Adjustments on Clinical Outcomes: The RAMP-IT-UP Multicenter Study , 2019, Circulation. Heart failure.

[41]  Ran Harel,et al.  Augmented reality-assisted pedicle screw insertion: a cadaveric proof-of-concept study. , 2019, Journal of neurosurgery. Spine.

[42]  K. Shah,et al.  International Society of Heart and Lung Transplantation position statement on the role of right heart catheterization in the management of heart transplant recipients. , 2019, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[43]  A. Behfar,et al.  Novel Use for Intracardiac Echocardiography: Evaluation of Patients With Continuous Flow Left Ventricular Assist Devices. , 2019, JACC. Cardiovascular imaging.

[44]  Brett A. Meyers,et al.  Colour-Doppler echocardiography flow field velocity reconstruction using a streamfunction–vorticity formulation , 2018, Journal of the Royal Society Interface.

[45]  K. Caliskan,et al.  Safety and feasibility of contrast echocardiography for the evaluation of patients with HeartMate 3 left ventricular assist devices , 2018, European heart journal cardiovascular Imaging.

[46]  J. Katz,et al.  Optimized Time-Resolved Echo Particle Image Velocimetry- Particle Tracking Velocimetry Measurements Elucidate Blood Flow in Patients With Left Ventricular Thrombus. , 2018, Journal of biomechanical engineering.

[47]  Jayeshkumar A. Patel,et al.  CT Imaging of Complications Associated with Continuous-Flow Left Ventricular Assist Devices (LVADs). , 2017, Seminars in ultrasound, CT, and MR.

[48]  M. Sedlmair,et al.  Iterative metal artefact reduction (MAR) in postsurgical chest CT: comparison of three iMAR-algorithms. , 2017, The British journal of radiology.

[49]  S. Gregory,et al.  Contrast Microsphere Destruction by a Continuous Flow Ventricular Assist Device: An In Vitro Evaluation Using a Mock Circulation Loop , 2017, BioMed research international.

[50]  G. Ewald,et al.  Hemocompatibility-Related Outcomes in the MOMENTUM 3 Trial at 6 Months: A Randomized Controlled Study of a Fully Magnetically Levitated Pump in Advanced Heart Failure , 2017, Circulation.

[51]  Hoong Sern Lim,et al.  The Physiology of Continuous-Flow Left Ventricular Assist Devices. , 2017, Journal of cardiac failure.

[52]  Ram P. Ghosh,et al.  Effect of Balloon-Expandable Transcatheter Aortic Valve Replacement Positioning: A Patient-Specific Numerical Model. , 2016, Artificial organs.

[53]  J. Butler,et al.  The Right Ventricular Function After Left Ventricular Assist Device (RVF-LVAD) study: rationale and preliminary results. , 2016, European heart journal cardiovascular Imaging.

[54]  Quan Long,et al.  Computational fluid dynamic study of hemodynamic effects on aortic root blood flow of systematically varied left ventricular assist device graft anastomosis design. , 2015, The Journal of thoracic and cardiovascular surgery.

[55]  N. Uriel,et al.  Serial echocardiography using tissue Doppler and speckle tracking imaging to monitor right ventricular failure before and after left ventricular assist device surgery. , 2013, JACC. Heart failure.

[56]  Christopher White,et al.  Echo particle image velocimetry. , 2012, Journal of visualized experiments : JoVE.

[57]  M. Esmaeilzadeh.,et al.  The Evolutionary Development of Echocardiography , 2012, Iranian journal of medical sciences.

[58]  J. Voigt,et al.  Can echocardiographic particle image velocimetry correctly detect motion patterns as they occur in blood inside heart chambers? A validation study using moving phantoms , 2012, Cardiovascular Ultrasound.

[59]  J. Kirklin,et al.  Use of Gated Cardiac Computed Tomography Angiography in the Assessment of Left Ventricular Assist Device Dysfunction , 2011, ASAIO journal.

[60]  W. Zoghbi,et al.  The role of echocardiography and other imaging modalities in patients with left ventricular assist devices. , 2010, JACC. Cardiovascular imaging.

[61]  Shmuel Einav,et al.  Design Optimization of a Mechanical Heart Valve for Reducing Valve Thrombogenicity—A Case Study with ATS Valve , 2010, ASAIO journal.

[62]  Danny Bluestein,et al.  Flow-induced platelet activation and damage accumulation in a mechanical heart valve: numerical studies. , 2007, Artificial organs.

[63]  T. MacGillivray,et al.  Perioperative Echocardiographic Examination for Ventricular Assist Device Implantation , 2007, Anesthesia and analgesia.

[64]  C. Visser,et al.  Microbubbles and ultrasound: from diagnosis to therapy. , 2004, European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology.

[65]  Jean Hertzberg,et al.  Development and validation of echo PIV , 2004 .

[66]  Toyoichi Tanaka,et al.  Blood Velocity Measurements in Human Retinal Vessels , 1974, Science.

[67]  Selim Bozkurt,et al.  Pressure, Flow Rate and Operating Speed Characteristics of a Continuous Flow Left Ventricular Assist Device During Varying Speed Support , 2020, IEEE Access.

[68]  J. Voorneveld,et al.  High-Frame-Rate Echo-Particle Image Velocimetry Can Measure the High-Velocity Diastolic Flow Patterns. , 2019, Circulation. Cardiovascular imaging.

[69]  Selim Bozkurt,et al.  In-silico evaluation of left ventricular unloading under varying speed continuous flow left ventricular assist device support , 2017 .

[70]  W. Pae,et al.  Intracardiac echocardiography for diagnosis and management of left ventricular assist device inlet obstruction. , 2014, ASAIO journal.

[71]  S. Einav,et al.  Progression of Abdominal Aortic Aneurysm Towards Rupture: Refining Clinical Risk Assessment Using a Fully Coupled Fluid–Structure Interaction Method , 2014, Annals of Biomedical Engineering.