Unobtrusive ECG monitoring in the NICU using a capacitive sensing array

The thin skin of preterm babies is easily damaged by adhesive electrodes, tapes, chest drains and needle-marks. The scars caused could be disfiguring or disabling to 10% of preterm newborns. Capacitive sensors present an attractive option for pervasively monitoring neonatal ECG, and can be embedded in a support system or even a garment worn by the neonate. This could improve comfort and reduce pain aiding better recovery as well as avoiding the scars caused by adhesive electrodes. In this work, we investigate the use of an array of capacitive sensors unobtrusively embedded in a mattress and used in a clinical environment for 15 preterm neonates. We also describe the analysis framework including the fusion of information from all sensors to provide a more accurate ECG signal. We propose a channel selection strategy as well as a method using physiological information to obtain a reliable ECG signal. When sensor coverage is well attained, results for both instantaneous heart rate and ECG signal shape analysis are very encouraging. The study also provides several insights on important factors affecting the results. These include the effect of textile type, number of layers, interferences (e.g. people walking by), motion severity and interventions. Incorporating this knowledge in the design of a capacitive sensing system would be crucial in ensuring that these sensors provide a reliable ECG signal when embedded in a neonatal support system.

[1]  Joos Vandewalle,et al.  Fetal electrocardiogram extraction by blind source subspace separation , 2000, IEEE Transactions on Biomedical Engineering.

[2]  C H L Peters,et al.  A robust physiology-based source separation method for QRS detection in low amplitude fetal ECG recordings , 2010, Physiological measurement.

[3]  P. Fu,et al.  Kangaroo Care modifies preterm infant heart rate variability in response to heel stick pain: pilot study. , 2009, Early human development.

[4]  Albrecht Schmidt,et al.  A Capacitive Sensing Toolkit for Pervasive Activity Detection and Recognition , 2007, Fifth Annual IEEE International Conference on Pervasive Computing and Communications (PerCom'07).

[5]  M Oehler,et al.  A multichannel portable ECG system with capacitive sensors , 2008, Physiological measurement.

[6]  Tsuyoshi Kato,et al.  Capacitive Sensing of Electrocardiographic Potential Through Cloth From the Dorsal Surface of the Body in a Supine Position: A Preliminary Study , 2007, IEEE Transactions on Biomedical Engineering.

[7]  César Sánchez,et al.  Convolutive Blind Source Separation Algorithms Applied to the Electrocardiogram of Atrial Fibrillation: Study of Performance , 2007, IEEE Transactions on Biomedical Engineering.

[8]  T. Shwayder,et al.  Neonatal skin barrier: structure, function, and disorders , 2005, Dermatologic therapy.

[9]  Steffen Leonhardt,et al.  Automatic electrode selection in unobtrusive capacitive ECG measurements , 2012, 2012 25th IEEE International Symposium on Computer-Based Medical Systems (CBMS).

[10]  S. Leonhardt,et al.  Non-contact ECG monitoring for automotive application , 2008, 2008 5th International Summer School and Symposium on Medical Devices and Biosensors.

[11]  Ko Keun Kim,et al.  The ECG measurement in the bathtub using the insulated electrodes , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[12]  Lars S. Maier,et al.  First clinical evaluation of a novel capacitive ECG system in patients with acute myocardial infarction , 2011, Clinical Research in Cardiology.

[13]  Pablo Laguna,et al.  A wavelet-based ECG delineator: evaluation on standard databases , 2004, IEEE Transactions on Biomedical Engineering.

[14]  Rik Vullings,et al.  An Adaptive Kalman Filter for ECG Signal Enhancement , 2011, IEEE Transactions on Biomedical Engineering.

[15]  Massimo Mischi,et al.  Low-complexity R-peak detection for ambulatory fetal monitoring , 2012, Physiological measurement.

[16]  N. Hussain,et al.  Effects of skin-to-skin contact on autonomic pain responses in preterm infants. , 2012, The journal of pain : official journal of the American Pain Society.

[17]  A. Bhutta,et al.  Vulnerability of the developing brain. Neuronal mechanisms. , 2002, Clinics in perinatology.

[18]  Jorge Henriques,et al.  Automatic Parameter Extraction from Capacitive ECG Measurements , 2012 .

[19]  Y. Yama,et al.  Development of a Wireless Capacitive Sensor for Ambulatory ECG Monitoring over Clothes , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[20]  Hanqing Cao,et al.  Cardiovascular oscillations at the bedside: early diagnosis of neonatal sepsis using heart rate characteristics monitoring , 2011, Physiological measurement.

[21]  K. Park,et al.  The electrically noncontacting ECG measurement on the toilet seat using the capacitively-coupled insulated electrodes , 2004, The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[22]  Akinori Ueno,et al.  An Application of Capacitive Electrode for Detecting Electrocardiogram of Neonates and Infants , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[23]  N. Evans,et al.  Development of the epidermis in the newborn. , 1986, Biology of the neonate.