Role of air changes per hour (ACH) in possible transmission of airborne infections

The cost of nosocomial infections in the United States is estimated to be $4 billion to $5 billion annually. Applying a scientifically based analysis to disease transmission and performing a site specific risk analysis to determine the design of the ventilation system can provide real and long term cost savings. Using a scientific approach and convincing data, this paper hypothetically illustrates how a ventilation system design can be optimized to potentially reduce infection risk to occupants in an isolation room based on a thorough risk assessment without necessarily increasing ventilation airflow rate. A computational fluid dynamics (CFD) analysis was performed to examine the transport mechanism, particle path and a suggested control strategy for reducing airborne infectious disease agents. Most studies on the transmission of infectious disease particles have concentrated primarily on air changes per hour (ACH) and how ACH provides a dilution factor for possible infectious agents. Although increasing ventilation airflow rate does dilute concentrations better when the contaminant source is constant, it does not increase ventilation effectiveness. Furthermore, an extensive literature review indicates that not every exposure to an infectious agent will necessarily cause a recipient infection. The results of this study suggest a hypothesis that in an enclosed and mechanically ventilated room (e.g., an isolation room), the dominant factor that affects the transmission and control of contaminants is the path between the contaminant source and exhaust. Contaminants are better controlled when this path is uninterrupted by an air stream. This study illustrates that the ventilation system design, i.e., when it conforms with the hypothesized path principle, may be a more important factor than flow rate (i.e., ACH). A secondary factor includes the distance from the contaminant source. This study provides evidence and supports previous studies that moving away from the patient generally reduces the infection risk in a transient (coughing) situation, although the effect is more pronounced under higher flow rate. It is noted that future research is needed to determine the exact mode of transmission for most recently identified organisms.

[1]  A. Hubbard,et al.  Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens , 2005, Journal of occupational and environmental hygiene.

[2]  Bin Zhao,et al.  The effectiveness of an air cleaner in controlling droplet/aerosol particle dispersion emitted from a patient's mouth in the indoor environment of dental clinics , 2010, Journal of The Royal Society Interface.

[3]  Vipin Kaushal Environmental Control Including Ventilation In Hospitals , 2004 .

[4]  M. P. Wan,et al.  Transport and Removal of Expiratory Droplets in Hospital Ward Environment , 2008 .

[5]  F. Memarzadeh The Environment of Care and Health Care-Associated Infections An Engineering Perspective , 2011 .

[6]  E. Cole,et al.  Characterization of infectious aerosols in health care facilities: An aid to effective engineering controls and preventive strategies☆☆☆★ , 1998, American Journal of Infection Control.

[7]  Angus Nicoll,et al.  Avian influenza A (H5N1) infection in humans. , 2005, The New England journal of medicine.

[8]  K.W.D. Cheong,et al.  Development of ventilation design strategy for effective removal of pollutant in the isolation room of a hospital , 2006 .

[9]  Couch Rb Viruses and indoor air pollution. , 1981 .

[10]  P V Nielsen,et al.  Distribution of exhaled contaminants and personal exposure in a room using three different air distribution strategies. , 2012, Indoor air.

[11]  Y. Li,et al.  Role of air distribution in SARS transmission during the largest nosocomial outbreak in Hong Kong. , 2005, Indoor air.

[12]  Chao-Hsin Lin,et al.  Characterizing exhaled airflow from breathing and talking. , 2010, Indoor air.

[13]  William J. Fisk,et al.  Review of health and productivity gains from better IEQ , 2000 .

[14]  G Murphy,et al.  Airborne spread of measles in a suburban elementary school. , 1978, American journal of epidemiology.

[15]  P. Höppe,et al.  Temperatures of expired air under varying climatic conditions , 1981, International journal of biometeorology.

[16]  K. Habel Mumps and Chiekenpox as Air-Borne Diseases. , 1945 .

[17]  John E. Bennett,et al.  Principles and practice of infectious diseases. Vols 1 and 2. , 1979 .

[18]  J. F. Stampfer,et al.  Particle concentration in exhaled breath. , 1987, American Industrial Hygiene Association journal.

[19]  Qingyan Chen,et al.  Experimental Study on Displacement and Mixing Ventilation Systems for a Patient Ward , 2009 .

[20]  Dereje Agonafer,et al.  LVEL turbulence model for conjugate heat transfer at low Reynolds numbers , 1996 .

[21]  K. Schaal Medical and microbiological problems arising from airborne infection in hospitals , 1991, Journal of Hospital Infection.

[22]  W. Bennett Effect of β-adrenergic agonists on mucociliary clearance , 2002 .

[23]  Cover Sheet DROPLET FATE IN INDOOR ENVIRONMENTS , OR CAN WE PREVENT THE SPREAD OF INFECTION ? , 2007 .

[24]  A. Nicolle,et al.  Observing and quantifying airflows in the infection control of aerosol- and airborne-transmitted diseases: an overview of approaches , 2010, Journal of Hospital Infection.

[25]  C. Glen Mayhall,et al.  Hospital Epidemiology and Infection Control , 2011 .

[26]  J. Farrar,et al.  WRITING COMMITTEE OF THE WORLD HEALTH ORGANIZATION (WHO) CONSULTATION ON HUMAN INFLUENZA A/H5. AVIAN INFLUENZA A (H5N1) INFECTION IN HUMANS , 2005 .

[27]  Yang-Cheng Shih,et al.  Numerical study on the dispersion of airborne contaminants from an isolation room in the case of door opening , 2008, Applied Thermal Engineering.

[28]  C. Chao,et al.  Transport characteristics of expiratory droplets and droplet nuclei in indoor environments with different ventilation airflow patterns. , 2007, Journal of biomechanical engineering.

[29]  Arsen Krikor Melikov,et al.  Exposure of health care workers and occupants to coughed airborne pathogens in a double-bed hospital patient room with overhead mixing ventilation , 2012, HVAC&R Research.

[30]  Gerhard Scheuch,et al.  Inhaling to mitigate exhaled bioaerosols. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[31]  Chao-Hsin Lin,et al.  Flow dynamics and characterization of a cough. , 2009, Indoor air.

[32]  Refrigerating ASHRAE handbook of fundamentals , 1967 .

[33]  Shih-Cheng Hu,et al.  An experimental study on ventilation efficiency of isolation room , 2009 .

[34]  F S Rosenthal,et al.  The size distribution of droplets in the exhaled breath of healthy human subjects. , 1997, Journal of aerosol medicine : the official journal of the International Society for Aerosols in Medicine.

[35]  C. Chao,et al.  A methodology for estimating airborne virus exposures in indoor environments using the spatial distribution of expiratory aerosols and virus viability characteristics. , 2008, Indoor air.

[36]  S. Squillace,et al.  Environmental control , 1992, Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery.

[37]  E. A. Hathway,et al.  The ventilation of multiple-bed hospital wards: review and analysis. , 2008, American journal of infection control.

[38]  L. Lambert,et al.  Guidelines for preventing the transmission of Mycobacterium tuberculosis in health-care settings, 2005. , 2005, MMWR. Recommendations and reports : Morbidity and mortality weekly report. Recommendations and reports.

[39]  Clifford Goodman,et al.  American Society of Mechanical Engineers , 1988 .

[40]  S. Kato,et al.  Investigation into airborne transport characteristics of airflow due to coughing in a stagnant indoor environment , 2006 .

[41]  William Firth Wells,et al.  THE ENVIRONMENTAL CONTROL OF EPIDEMIC CONTAGIONI. AN EPIDEMIOLOGIC STUDY OF RADIANT DISINFECTION OF AIR IN DAY SCHOOLS , 1942 .

[42]  J. Haas Measurement of infection control department performance: state of the science. , 2006, American journal of infection control.

[43]  B. Launder,et al.  The numerical computation of turbulent flows , 1990 .

[44]  A. Langmuir,et al.  CHANGING CONCEPTS OF AIRBORNE INFECTION OF ACUTE CONTAGIOUS DISEASES: A RECONSIDERATION OF CLASSIC EPIDEMIOLOGIC THEORIES , 1980, Annals of the New York Academy of Sciences.

[45]  I. Orme,et al.  Cough-generated aerosols of Mycobacterium tuberculosis: a new method to study infectiousness. , 2004, American journal of respiratory and critical care medicine.

[46]  H. Laborit,et al.  [Experimental study]. , 1958, Bulletin mensuel - Societe de medecine militaire francaise.

[47]  Y. Li,et al.  How far droplets can move in indoor environments--revisiting the Wells evaporation-falling curve. , 2007, Indoor air.

[48]  Deborah Braccia,et al.  Systematic review of economic analyses of health care-associated infections. , 2005, American journal of infection control.

[49]  W. Bennett Effect of beta-adrenergic agonists on mucociliary clearance. , 2002, The Journal of allergy and clinical immunology.

[50]  J. Regnard,et al.  Nasal mucociliary transport in healthy subjects is slower when breathing dry air. , 1988, The European respiratory journal.

[51]  D. Maki,et al.  Relation of the inanimate hospital environment to endemic nosocomial infection. , 1982, The New England journal of medicine.

[52]  P V Nielsen,et al.  Role of ventilation in airborne transmission of infectious agents in the built environment - a multidisciplinary systematic review. , 2007, Indoor air.

[53]  R. Scott,et al.  The Direct medical costs of healthcare-associated infections in U.S. hospitals and the benefits of prevention , 2009 .

[54]  J. Ji,et al.  Transport of Droplets Expelled by Coughing in Ventilated Rooms , 2007 .

[55]  R. Couch Viruses and indoor air pollution. , 1981, Bulletin of the New York Academy of Medicine.

[56]  Kerrie Mengersen,et al.  Size distribution and sites of origin of droplets expelled from the human respiratory tract during expiratory activities , 2009 .

[57]  M. P. Wan,et al.  Modeling the Fate of Expiratory Aerosols and the Associated Infection Risk in an Aircraft Cabin Environment , 2009 .

[58]  F. Dutra,et al.  Airborne Contagion and Air Hygiene: An Ecological Study of Droplet Infections , 1955 .