Multisite longitudinal reliability of tract-based spatial statistics in diffusion tensor imaging of healthy elderly subjects

Large-scale longitudinal neuroimaging studies with diffusion imaging techniques are necessary to test and validate models of white matter neurophysiological processes that change in time, both in healthy and diseased brains. The predictive power of such longitudinal models will always be limited by the reproducibility of repeated measures acquired during different sessions. At present, there is limited quantitative knowledge about the across-session reproducibility of standard diffusion metrics in 3T multi-centric studies on subjects in stable conditions, in particular when using tract based spatial statistics and with elderly people. In this study we implemented a multi-site brain diffusion protocol in 10 clinical 3T MRI sites distributed across 4 countries in Europe (Italy, Germany, France and Greece) using vendor provided sequences from Siemens (Allegra, Trio Tim, Verio, Skyra, Biograph mMR), Philips (Achieva) and GE (HDxt) scanners. We acquired DTI data (2 × 2 × 2 mm(3), b = 700 s/mm(2), 5 b0 and 30 diffusion weighted volumes) of a group of healthy stable elderly subjects (5 subjects per site) in two separate sessions at least a week apart. For each subject and session four scalar diffusion metrics were considered: fractional anisotropy (FA), mean diffusivity (MD), radial diffusivity (RD) and axial (AD) diffusivity. The diffusion metrics from multiple subjects and sessions at each site were aligned to their common white matter skeleton using tract-based spatial statistics. The reproducibility at each MRI site was examined by looking at group averages of absolute changes relative to the mean (%) on various parameters: i) reproducibility of the signal-to-noise ratio (SNR) of the b0 images in centrum semiovale, ii) full brain test-retest differences of the diffusion metric maps on the white matter skeleton, iii) reproducibility of the diffusion metrics on atlas-based white matter ROIs on the white matter skeleton. Despite the differences of MRI scanner configurations across sites (vendors, models, RF coils and acquisition sequences) we found good and consistent test-retest reproducibility. White matter b0 SNR reproducibility was on average 7 ± 1% with no significant MRI site effects. Whole brain analysis resulted in no significant test-retest differences at any of the sites with any of the DTI metrics. The atlas-based ROI analysis showed that the mean reproducibility errors largely remained in the 2-4% range for FA and AD and 2-6% for MD and RD, averaged across ROIs. Our results show reproducibility values comparable to those reported in studies using a smaller number of MRI scanners, slightly different DTI protocols and mostly younger populations. We therefore show that the acquisition and analysis protocols used are appropriate for multi-site experimental scenarios.

[1]  Jeremy D. Schmahmann,et al.  Diffusion spectrum magnetic resonance imaging (DSI) tractography of crossing fibers , 2008, NeuroImage.

[2]  Jorge Jovicich,et al.  Reproducibility and biases in high field brain diffusion MRI: An evaluation of acquisition and analysis variables. , 2013, Magnetic resonance imaging.

[3]  Stefan Klein,et al.  Improving alignment in Tract-based spatial statistics: Evaluation and optimization of image registration , 2013, NeuroImage.

[4]  M. Jenkinson Non-linear registration aka Spatial normalisation , 2007 .

[5]  Guy B. Williams,et al.  Looking for the optimal DTI acquisition scheme given a maximum scan time: are more b-values a waste of time? , 2009, Magnetic resonance imaging.

[6]  John S. Duncan,et al.  Identical, but not the same: Intra-site and inter-site reproducibility of fractional anisotropy measures on two 3.0 T scanners , 2010, NeuroImage.

[7]  Jessica A. Turner,et al.  MultiCenter Reliability of Diffusion Tensor Imaging , 2012, Brain Connect..

[8]  Carl-Fredrik Westin,et al.  Excessive Extracellular Volume Reveals a Neurodegenerative Pattern in Schizophrenia Onset , 2012, The Journal of Neuroscience.

[9]  P. Hagmann,et al.  Mapping complex tissue architecture with diffusion spectrum magnetic resonance imaging , 2005, Magnetic resonance in medicine.

[10]  Jane S. Paulsen,et al.  Diffusion Tensor Imaging in Preclinical Huntington’s Disease , 2009, Brain Imaging and Behavior.

[11]  Antti Saastamoinen,et al.  Diffusion tensor imaging of the brain in a healthy adult population: Normative values and measurement reproducibility at 3 T and 1.5 T , 2010, Acta radiologica.

[12]  J. Debbins,et al.  A Validation Study of Multicenter Diffusion Tensor Imaging: Reliability of Fractional Anisotropy and Diffusivity Values , 2012, American Journal of Neuroradiology.

[13]  Marco Rovaris,et al.  DTI Parameter Optimisation for Acquisition at 1.5T: SNR Analysis and Clinical Application , 2010, Comput. Intell. Neurosci..

[14]  Marco Rovaris,et al.  Intercenter differences in diffusion tensor MRI acquisition , 2010, Journal of magnetic resonance imaging : JMRI.

[15]  Jun Yoshino,et al.  Demyelination increases radial diffusivity in corpus callosum of mouse brain , 2005, NeuroImage.

[16]  David H. Salat,et al.  Non-Gaussian water diffusion in aging white matter , 2014, Neurobiology of Aging.

[17]  P. Scheltens,et al.  A New Rating Scale for Age-Related White Matter Changes Applicable to MRI and CT , 2001, Stroke.

[18]  D. Reich,et al.  Longitudinal changes in diffusion tensor–based quantitative MRI in multiple sclerosis , 2011, Neurology.

[19]  A. Mayer,et al.  Head injury or head motion? Assessment and quantification of motion artifacts in diffusion tensor imaging studies , 2012, Human brain mapping.

[20]  Andreas Engvig,et al.  Memory training impacts short‐term changes in aging white matter: A Longitudinal Diffusion Tensor Imaging Study , 2012, Human brain mapping.

[21]  S. Mori,et al.  Principles of Diffusion Tensor Imaging and Its Applications to Basic Neuroscience Research , 2006, Neuron.

[22]  Jacobus F. A. Jansen,et al.  The effect and reproducibility of different clinical DTI gradient sets on small world brain connectivity measures , 2010, NeuroImage.

[23]  Massimo Filippi,et al.  A diffusion tensor MRI study of patients with MCI and AD with a 2-year clinical follow-up , 2010, Journal of Neurology, Neurosurgery & Psychiatry.

[24]  Mara Cercignani,et al.  Twenty‐five pitfalls in the analysis of diffusion MRI data , 2010, NMR in biomedicine.

[25]  S. Schoenberg,et al.  Measurement of signal‐to‐noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters , 2007, Journal of magnetic resonance imaging : JMRI.

[26]  Geoffrey J M Parker,et al.  A framework for a streamline‐based probabilistic index of connectivity (PICo) using a structural interpretation of MRI diffusion measurements , 2003, Journal of magnetic resonance imaging : JMRI.

[27]  P. E. Morris,et al.  Water proton T1 measurements in brain tissue at 7, 3, and 1.5T using IR-EPI, IR-TSE, and MPRAGE: results and optimization , 2008, Magnetic Resonance Materials in Physics, Biology and Medicine.

[28]  Marina Boccardi,et al.  The Italian Brain Normative Archive of structural MR scans: norms for medial temporal atrophy and white matter lesions , 2009, Aging clinical and experimental research.

[29]  Carlo Pierpaoli,et al.  Regional distribution of measurement error in diffusion tensor imaging , 2006, Psychiatry Research: Neuroimaging.

[30]  Yi Wang,et al.  Quality control of diffusion weighted images , 2010, Medical Imaging.

[31]  S. Holland,et al.  NMR relaxation times in the human brain at 3.0 tesla , 1999, Journal of magnetic resonance imaging : JMRI.

[32]  Claudio Babiloni,et al.  Disease tracking markers for Alzheimer's disease at the prodromal (MCI) stage. , 2011, Journal of Alzheimer's disease : JAD.

[33]  A. Toga,et al.  Multisite neuroimaging trials , 2009, Current opinion in neurology.

[34]  N. Intrator,et al.  Free water elimination and mapping from diffusion MRI , 2009, Magnetic resonance in medicine.

[35]  Klaas Nicolay,et al.  Reproducibility of Quantitative Cerebral T2 Relaxometry, Diffusion Tensor Imaging, and 1H Magnetic Resonance Spectroscopy at 3.0 Tesla , 2007, Investigative radiology.

[36]  Daniel Rueckert,et al.  Tract-based spatial statistics: Voxelwise analysis of multi-subject diffusion data , 2006, NeuroImage.

[37]  T. Jernigan,et al.  Diffusion tensor imaging during recovery from severe traumatic brain injury and relation to clinical outcome: a longitudinal study. , 2008, Brain : a journal of neurology.

[38]  A Pfefferbaum,et al.  Neuroradiological characterization of normal adult ageing. , 2007, The British journal of radiology.

[39]  M. Catani,et al.  Diffusion-based tractography in neurological disorders: concepts, applications, and future developments , 2008, The Lancet Neurology.

[40]  E. Fieremans,et al.  Novel White Matter Tract Integrity Metrics Sensitive to Alzheimer Disease Progression , 2013, American Journal of Neuroradiology.

[41]  大内 宏之 Diffusion anisotropy measurement of brain white matter is affected by voxel size : underestimation occurs in areas with crossing fibers , 2007 .

[42]  G. Marchal,et al.  Quantitative diffusion tensor imaging in amyotrophic lateral sclerosis: Revisited , 2009, Human brain mapping.

[43]  P. Basser,et al.  Microstructural and physiological features of tissues elucidated by quantitative-diffusion-tensor MRI. , 1996, Journal of magnetic resonance. Series B.

[44]  A. Pfefferbaum,et al.  Replicability of diffusion tensor imaging measurements of fractional anisotropy and trace in brain , 2003, Journal of magnetic resonance imaging : JMRI.

[45]  C. Lebel,et al.  Longitudinal Development of Human Brain Wiring Continues from Childhood into Adulthood , 2011, The Journal of Neuroscience.

[46]  Naoto Hayashi,et al.  Effect of scanner in longitudinal diffusion tensor imaging studies , 2012, Human brain mapping.

[47]  Xing Qiu,et al.  Quantification of accuracy and precision of multi-center DTI measurements: A diffusion phantom and human brain study , 2011, NeuroImage.

[48]  H. Hampel,et al.  Longitudinal changes of fractional anisotropy in Alzheimer’s disease patients treated with galantamine: a 12-month randomized, placebo-controlled, double-blinded study , 2012, European Archives of Psychiatry and Clinical Neuroscience.

[49]  C. Jack,et al.  Dementia with Lewy bodies and Alzheimer disease , 2010, Neurology.

[50]  C. Wheeler-Kingshott,et al.  About “axial” and “radial” diffusivities , 2009, Magnetic resonance in medicine.

[51]  Alexander Leemans,et al.  The B‐matrix must be rotated when correcting for subject motion in DTI data , 2009, Magnetic resonance in medicine.

[52]  Timothy Edward John Behrens,et al.  Between session reproducibility and between subject variability of diffusion MR and tractography measures , 2006, NeuroImage.

[53]  John L Bradshaw,et al.  A longitudinal diffusion tensor imaging study in symptomatic Huntington's disease , 2009, Journal of Neurology, Neurosurgery & Psychiatry.

[54]  Bram Stieltjes,et al.  Longitudinal changes in fiber tract integrity in healthy aging and mild cognitive impairment: a DTI follow-up study. , 2010, Journal of Alzheimer's disease : JAD.

[55]  James J. Pekar,et al.  Regionally-specific diffusion tensor imaging in mild cognitive impairment and Alzheimer's disease , 2009, NeuroImage.

[56]  Michael Brady,et al.  Improved Optimization for the Robust and Accurate Linear Registration and Motion Correction of Brain Images , 2002, NeuroImage.

[57]  Jerry L Prince,et al.  Effects of signal‐to‐noise ratio on the accuracy and reproducibility of diffusion tensor imaging–derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5T , 2007, Journal of magnetic resonance imaging : JMRI.

[58]  Xue Wang,et al.  Reproducibility of Structural, Resting-State BOLD and DTI Data between Identical Scanners , 2012, PloS one.

[59]  A. Dale,et al.  Life-span changes of the human brain white matter: diffusion tensor imaging (DTI) and volumetry. , 2010, Cerebral cortex.

[60]  Timothy Edward John Behrens,et al.  Characterization and propagation of uncertainty in diffusion‐weighted MR imaging , 2003, Magnetic resonance in medicine.

[61]  Vincent A Magnotta,et al.  Global white matter abnormalities in schizophrenia: a multisite diffusion tensor imaging study. , 2011, Schizophrenia bulletin.

[62]  Andreas Hadjiprocopis,et al.  Longitudinal evaluation of clinically early relapsing-remitting multiple sclerosis with diffusion tensor imaging , 2008, Journal of Neurology.

[63]  Randy L. Gollub,et al.  Reproducibility of quantitative tractography methods applied to cerebral white matter , 2007, NeuroImage.

[64]  Giovanni B. Frisoni,et al.  Brain morphometry reproducibility in multi-center 3T MRI studies: A comparison of cross-sectional and longitudinal segmentations , 2013, NeuroImage.

[65]  Nancy Kanwisher,et al.  Spurious group differences due to head motion in a diffusion MRI study , 2013, NeuroImage.

[66]  D. Bohning,et al.  Reproducibility, Interrater Agreement, and Age-Related Changes of Fractional Anisotropy Measures at 3T in Healthy Subjects: Effect of the Applied b-Value , 2008, American Journal of Neuroradiology.

[67]  Michael E. Moseley,et al.  Longitudinal changes in white matter following ischemic stroke: A three-year follow-up study , 2006, Neurobiology of Aging.

[68]  Gareth J. Barker,et al.  From diffusion tractography to quantitative white matter tract measures: a reproducibility study , 2003, NeuroImage.

[69]  David Bonekamp,et al.  Diffusion tensor imaging in children and adolescents: Reproducibility, hemispheric, and age-related differences , 2007, NeuroImage.

[70]  Alessandra Bertoldo,et al.  Cortical diffusion-tensor imaging abnormalities in multiple sclerosis: a 3-year longitudinal study. , 2011, Radiology.

[71]  Daniel Rueckert,et al.  Nonrigid registration using free-form deformations: application to breast MR images , 1999, IEEE Transactions on Medical Imaging.

[72]  Torsten Rohlfing,et al.  Longitudinal Study of Callosal Microstructure in the Normal Adult Aging Brain Using Quantitative DTI Fiber Tracking , 2010, Developmental neuropsychology.

[73]  Khader M Hasan,et al.  Volumetric navigators for real‐time motion correction in diffusion tensor imaging , 2012, Magnetic resonance in medicine.

[74]  Kurt E. Weaver,et al.  Longitudinal diffusion tensor imaging in Huntington's Disease , 2009, Experimental Neurology.

[75]  Jerry L. Prince,et al.  Effects of diffusion weighting schemes on the reproducibility of DTI-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5T , 2007, NeuroImage.