Electrode polarization correction in time domain dielectric spectroscopy

Three methods of electrode polarization correction developed for time domain dielectric spectroscopy are reviewed in the paper. Two of them are based on the representation of the parasitic double electrical layer by an additional capacitor connected in series with the working electrodes of the sample holder. The third one takes into account the fractal nature of electrode polarization. The advantages and limitations of each method are discussed in the review.

[1]  Y. Feldman,et al.  Treatment of TDS data for the lumped-capacitance method. Frequency-domain treatment , 1979 .

[2]  Alignment of nematic liquid crystals on ruled grating surfaces , 1981 .

[3]  Yuri Feldman,et al.  Time domain dielectric spectroscopy: An advanced measuring system , 1996 .

[4]  Y. Feldman,et al.  Time domain dielectric spectroscopy study of human cells. I. Erythrocytes and ghosts. , 1996, Biochimica et biophysica acta.

[5]  Niklasson,et al.  Determination of fractal dimension by cyclic I-V studies: The Laplace-transform method. , 1995, Physical review. B, Condensed matter.

[6]  Y. Feldman,et al.  Time domain dielectric spectroscopy. A new effective tool for physical chemistry investigation , 1992 .

[7]  N. Shinyashiki,et al.  Evaluation of complex permittivity of aqueous solution by time domain reflectometry , 1987 .

[8]  M. Gemert Theoretical analysis of the lumped capacitance method in dielectric time domain spectroscopy , 1974 .

[9]  Yuri Feldman,et al.  Fractal-polarization correction in time domain dielectric spectroscopy , 1998 .

[10]  E. Grant,et al.  Dielectric Behavior of Water at Microwave Frequencies , 1957 .

[11]  Y. Feldman,et al.  Time domain dielectric spectroscopy with nonuniform signal sampling , 1991 .

[12]  Christopher L. Davey,et al.  The influence of electrode polarisation on dielectric spectra, with special reference to capacitive biomass measurements I. Quantifying the effects on electrode polarisation of factors likely to occur during fermentations , 1998 .

[13]  Y. Feldman,et al.  Treatment of time-domain spectroscopy data in the lumped-capacitance method. Further considerations , 1980 .

[14]  Pajkossy,et al.  Scaling-law analysis to describe the impedance behavior of fractal electrodes. , 1990, Physical review. B, Condensed matter.

[15]  H P Schwan,et al.  ELECTRODE POLARIZATION IMPEDANCE AND MEASUREMENTS IN BIOLOGICAL MATERIALS * , 1968, Annals of the New York Academy of Sciences.

[16]  Y. Lipatov,et al.  Adsorption and structure formation in solutions of polymer mixtures , 1986 .

[17]  G. Chryssikos,et al.  Time domain reflection methods for dielectric measurements to 10 GHz , 1989 .

[18]  Y. Feldman,et al.  Time domain treatment of TDS data for the lumped-capacitance method , 1978 .

[19]  D. Saville,et al.  Dielectric spectroscopy of colloidal suspensions: I. The dielectric spectrometer , 1989 .

[20]  W. Scheider Theory of the frequency dispersion of electrode polarization. Topology of networks with fractional power frequency dependence , 1975 .

[21]  A. Zanelli,et al.  Impedance spectroscopy in electrode/electrolyte interface investigations , 1994 .

[22]  R J Sheppard,et al.  Dielectric behaviour of biological molecules in solution , 1978 .

[23]  Christopher L. Davey,et al.  On the dielectric properties of cell suspensions at high volume fractions , 1992 .

[24]  R. Nozaki,et al.  Broadband complex permittivity measurements by time-domain spectroscopy , 1990 .

[25]  J. Maczuk,et al.  ON THE LOW-FREQUENCY DIELECTRIC DISPERSION OF COLLOIDAL PARTICLES IN ELECTROLYTE SOLUTION1 , 1962 .

[26]  Y. Feldman,et al.  Time domain dielectric spectroscopy study of human cells. II. Normal and malignant white blood cells. , 1999, Biochimica et biophysica acta.

[27]  T. Pajkossy,et al.  Impedance of rough capacitive electrodes , 1994 .