진동수응답함수 측정에 따른 펌프 가진력 산정
暂无分享,去创建一个
This is study to estimate the pump induced vibration in time and frequency domain by frequency response function between two points in case of 20Hp and 50Hp centrifugal pumps. The frequency response function has real and imaginary information of signals, and response function has also real and imaginary information. So the vibration force can be obtained from the response function and frequency response function by complex calculation. And it is compared with the theoretically estimated values and it is suggested that the amplitude of vibration with main frequency is about 10~25% of pump and motor weight, and the magnitude of unbalanced mass is about 30~60% of pump and motor weight to estimated vibration force in time domain. There are the other kinds of vibration components with different frequency values of 2~3 times of its main frequency, and these kinds of information are used to control the tuning ratio between operating frequency of pump and structural frequency of concrete slab.