Optimization of periodic testing frequency of a reactor protection system based on a risk-cost model and public risk perception

Techniques for optimizing the frequency of periodic surveillance testing of nuclear power plant (NPP) safety systems have been receiving increased attention and growing importance because of the need to reduce system unavailability and maintenance cost. Economic losses from maintenance human errors should be included in estimating periodic testing and maintenance costs because the losses increase with maintenance human errors. This paper proposes a method for optimizing periodic testing intervals of a digital reactor protection system by balancing risk and cost of periodic surveillance tests, in which maintenance human error and public risk perception have been reflected. The risk and costs were estimated from both plant operator and socio-economic standpoints. This model determines the optimal testing frequency for the minimum value of an objective function that consists of all costs, including the monetary values of the consequence of maintenance human errors and reactor core damage. We present a case study using our model for the OPR1000 plant. The study results show the significance of reducing human errors in periodic testing and maintenance. The proposed method is expected to be useful to NPP operators as well as regulators for evaluating the optimal periodic testing frequency of a nuclear reactor protection system and for obtaining information needed in decision making processes.

[1]  Louis Eeckhoudt,et al.  Risk aversion and the external cost of a nuclear accident , 2000 .

[2]  Cláudio Márcio N.A. Pereira,et al.  A model for preventive maintenance planning by genetic algorithms based in cost and reliability , 2006, Reliab. Eng. Syst. Saf..

[3]  Marvin Rausand,et al.  Spurious activation of safety instrumented systems in the oil and gas industry: Basic concepts and formulas , 2008, Reliab. Eng. Syst. Saf..

[4]  Joon-Eon Yang,et al.  Development of the methods to change the fault tree logic structure according to the changing conditions of a system in a one top PSA model , 2008 .

[5]  A. D. Swain,et al.  Handbook of human-reliability analysis with emphasis on nuclear power plant applications. Final report , 1983 .

[6]  David A. Cather,et al.  A Gentle Introduction to Risk Aversion and Utility Theory , 2010 .

[7]  M. M. Adibi,et al.  Nuclear plant requirements during power system restoration , 1995 .

[8]  Xue Dazhi,et al.  A genetic algorithm solution for a nuclear power plant risk–cost maintenance model , 2004 .

[9]  R. Billinton,et al.  Area Annual Outage Cost Assessment of KEPCO System by TRELSS , 2007, 2007 Large Engineering Systems Conference on Power Engineering.

[10]  Seung-Cheol Jang,et al.  ATWS Frequency Quantification Focusing on Digital I&C Failures , 2004 .

[11]  Jin Jiang,et al.  Analysis of surveillance test interval by Markov process for SDS1 in CANDU nuclear power plants , 2008, Reliab. Eng. Syst. Saf..

[12]  Poong Hyun Seong,et al.  Quantification of unavailability caused by random failures and maintenance human errors in nuclear power plants , 2010 .

[13]  J. Vaurio Optimization of test and maintenance intervals based on risk and cost , 1995 .

[14]  R. L. Brune,et al.  Peer-review study of the draft handbook for human-reliability analysis with emphasis on nuclear-power-plant applications, NUREG/CR-1278 , 1983 .

[15]  M. Chesney,et al.  Long-term risk management of nuclear waste: a real options approach , 2002 .

[16]  B. Mavko,et al.  Probabilistic safety assessment improves surveillance requirements in technical specifications , 1997 .

[17]  Sebastián Martorell,et al.  Modelling and optimization of proof testing policies for safety instrumented systems , 2009, Reliab. Eng. Syst. Saf..

[18]  Sandip Roy,et al.  Maintenance optimization using probabilistic cost-benefit analysis , 2009 .

[19]  K. Takano,et al.  Multivariate Analysis of Human Error Incidents Occurring at Nuclear Power Plants: Several Occurrence Patterns of Observed Human Errors , 2001, Cognition, Technology & Work.

[20]  Jaewhan Kim,et al.  Characteristics of test and maintenance human errors leading to unplanned reactor trips in nuclear power plants , 2009 .

[21]  Hyun Gook Kang,et al.  An analysis of safety-critical digital systems for risk-informed design , 2002, Reliab. Eng. Syst. Saf..

[22]  Sun Yeong Choi,et al.  An analysis for risk impact of Emergency Diesel Generator on modified Surveillance Test Interval by considering failure due to demand stress , 2010 .

[23]  R. Sturm,et al.  Why does nuclear power performance differ across Europe , 1995 .

[24]  Pekka Pyy,et al.  An analysis of maintenance failures at a nuclear power plant , 2001, Reliab. Eng. Syst. Saf..

[25]  Poong Hyun Seong,et al.  A model for estimation of reactor spurious shutdown rate considering maintenance human errors in reactor protection system of nuclear power plants , 2010 .

[26]  Ana Sánchez,et al.  RAMS+C informed decision-making with application to multi-objective optimization of technical specifications and maintenance using genetic algorithms , 2005, Reliab. Eng. Syst. Saf..

[27]  Enrico Zio,et al.  Multiobjective optimization of the inspection intervals of a nuclear safety system: A clustering-based framework for reducing the Pareto Front ☆ , 2010 .

[28]  T M Wu,et al.  Maintenance error reduction strategies in nuclear power plants, using root cause analysis. , 1989, Applied ergonomics.

[29]  Seung Jun Lee,et al.  AN OVERVIEW OF RISK QUANTIFICATION ISSUES FOR DIGITALIZED NUCLEAR POWER PLANTS USING A STATIC FAULT TREE , 2009 .