Development of Third-Harmonic 1.2-THz Gyrotron With Intentionally Increased Velocity Spread of Electrons

We develop the concept of a continuous wave (CW) 1.185 THz (wavelength about 250- $\mu \text{m}$ ) gyrotron with an output power of several watts, intended for dynamic nuclear polarization (DNP)/nuclear magnetic resonance (NMR) spectroscopy applications. For a 15-T magnetic field provided by a commercially available cryomagnet, the required frequency can be achieved by operating at the third cyclotron harmonic. Under conditions of extreme density of the mode spectrum, we propose using interaction with an electron beam intentionally formed with a high (up to 40%) velocity spread as a selection mechanism. This ensures suppression of the most dangerous parasitic traveling modes at the first and the second cyclotron harmonics, which are very sensitive to the spread. The main parameters of the gyrotron are determined both using the start currents analysis and within the framework of a nonstationary self-consistent model. Experimental feasibility of the single-mode third-harmonic generation under conditions of mode competition is verified based on 3-D particle-in-cell (PIC) simulations.

[1]  K. Avramidis,et al.  Improved Mode Selection in Coaxial Cavities for Subterahertz Second-Harmonic Gyrotrons , 2020, IEEE Transactions on Electron Devices.

[2]  A. Tsvetkov,et al.  Universal Electron Gun Design for a CW Third Harmonic Gyrotron with an Operating Frequency over 1 THz , 2020 .

[3]  K. Avramidis,et al.  Coaxial Cavity With Stepped Inner Conductor for a Sub-Terahertz Second-Harmonic Gyrotron With Broadband Continuous Frequency Tuning , 2019, IEEE Transactions on Electron Devices.

[4]  A. Fiks,et al.  Powerful continuous-wave sub-terahertz electron maser operating at the 3rd cyclotron harmonic , 2019, Applied Physics Letters.

[5]  A. Sedov,et al.  A novel THz-band double-beam gyrotron for high-field DNP-NMR spectroscopy. , 2017, The Review of scientific instruments.

[6]  M. Glyavin,et al.  Method of Providing the High Cyclotron Harmonic Operation Selectivity in a Gyrotron With a Spatially Developed Operating Mode , 2017, IEEE Transactions on Electron Devices.

[7]  O. Dumbrajs,et al.  Influence of the electron velocity spread and the beam width on the efficiency and mode competition in the high-power pulsed gyrotron for 300 GHz band collective Thomson scattering diagnostics in the large helical device , 2016 .

[8]  I. Zotova,et al.  Time-domain self-consistent theory of frequency-locking regimes in gyrotrons with low-Q resonators , 2015 .

[9]  G. Denisov,et al.  Experimental Study of the Pulsed Terahertz Gyrotron with Record-Breaking Power and Efficiency Parameters , 2014 .

[10]  M. Glyavin,et al.  Three-dimensional particle-in-cell modeling of terahertz gyrotrons with cylindrical and planar configurations of the interaction space , 2013 .

[11]  V. Manuilov,et al.  Large-Orbit Gyrotron operation in terahertz frequency range , 2009, 2009 IEEE International Conference on Plasma Science - Abstracts.

[12]  G. Golubiatnikov,et al.  Generation of 1.5-kW, 1-THz coherent radiation from a gyrotron with a pulsed magnetic field. , 2008, Physical review letters.

[13]  Seitaro Mitsudo,et al.  THE FIRST EXPERIMENT OF A THz GYROTRON WITH A PULSE MAGNET , 2007 .

[14]  T. Antonsen,et al.  Start currents in an overmoded gyrotron , 2003 .

[15]  V. Zapevalov,et al.  Efficiency Enhancement of the Relativistic Gyrotron , 2001 .

[16]  Toshitaka Idehara,et al.  Operation of a tunable gyrotron at the second harmonic of the electron cyclotron frequency , 1990 .

[17]  Gregory S. Nusinovich,et al.  Theory of non-stationary processes in gyrotrons with low Q resonators , 1986 .

[18]  E. Sokolov,et al.  Starting conditions of a CRM monotron in the presence of scatter of the velocities of the electrons , 1977 .