Perioperative Variation in Optic Nerve Sheath Diameter - A Prospective Observational Study of Traumatic Brain Injury Patients Undergoing Decompressive Craniectomy.

Background Measuring optic nerve sheath diameter (ONSD) by transbulbar ultrasonography (TBUS) can suffice non-invasive ICP measurement with considerable accuracy. Objective The primary objective of this study was to evaluate the perioperative variation in ONSD by TBUS in Traumatic Brain Injury (TBI) patients undergoing emergency craniectomy. Methods We prospectively compared bilateral ONSD measurements in 45 consecutive TBI cases undergoing decompressive craniectomy under general anesthesia; before and after surgery. A total of 180 ONSD images were obtained and measurements were done by the same investigator blinded to the pre/postoperative nature of the image. Results Based on preoperative Glasgow Coma Scores, 34 cases (75.5%) had severe TBI; 10 cases (22.2%) moderate TBI; and 1 case (2.2%) mild TBI. Preoperative ONSD in the study population were as 6.625 ± 0.414mm. Average ONSD reduced significantly by 0.249 ± 0.148 mm (P < 0.001) after craniectomy. On pooled analysis of cases undergoing right versus left sided craniectomy average ONSD reduced significantly by 0.252 ± 0.173 mm (P < 0.001) and 0.259 ± 0.139 mm (P < 0.001), respectively. ONSD of right eye with left eye and vice-versa were strongly correlated both pre/postoperatively with Pearson correlation coefficients (r)=0.879 (P < 0.001) and r = 0.827 (P < 0.001), respectively. Conclusions In TBI cases undergoing decompressive craniectomy ONSD is bilaterally increased preoperatively. ONSD reduces significantly immediately after craniectomy; however, the diameters did not near the normal range. There hold a strong correlation between right/left ONSD measurements irrespective of the laterality of injury or side of surgery. Variable elastic properties of ONS in an injured brain can possibly explain our findings.

[1]  C. Callaway,et al.  Ultrasound measurement of optic nerve sheath diameter pre- and post-lumbar puncture , 2020, The Ultrasound Journal.

[2]  S. Lee,et al.  Optic nerve sheath diameter measurement for predicting raised intracranial pressure in adult patients with severe traumatic brain injury: A meta-analysis. , 2020, Journal of critical care.

[3]  Aussama K. Nassar,et al.  Bedside Optic Nerve Ultrasonography for Diagnosing Increased Intracranial Pressure , 2019, Annals of Internal Medicine.

[4]  R. Bala,et al.  A study to evaluate effect of PEEP and end-tidal carbon dioxide on optic nerve sheath diameter , 2019, Indian journal of anaesthesia.

[5]  R. Cheng,et al.  Comparison of Two Techniques to Measure Optic Nerve Sheath Diameter in Patients at Risk for Increased Intracranial Pressure , 2019, Critical care medicine.

[6]  S. Lee,et al.  Diagnostic performance of optic nerve sheath diameter for predicting neurologic outcome in post-cardiac arrest patients: A systematic review and meta-analysis. , 2019, Resuscitation.

[7]  S. Adinarayanan,et al.  Measurement of changes in optic nerve sheath diameter using ultrasound and computed tomography scan before and after the ventriculoperitoneal shunt surgery in patients with hydrocephalus - A prospective observational trial , 2019, British journal of neurosurgery.

[8]  Sojib Bin Zaman,et al.  Global, regional, and national burden of traumatic brain injury and spinal cord injury, 1990–2016: a systematic analysis for the Global Burden of Disease Study 2016 , 2019, The Lancet Neurology.

[9]  Amit Agrawal,et al.  Estimating the global incidence of traumatic brain injury. , 2019, Journal of neurosurgery.

[10]  Chunshuang Wu,et al.  Diagnostic and prognostic value of the optic nerve sheath diameter with respect to the intracranial pressure and neurological outcome of patients following hemicraniectomy , 2018, BMC Neurology.

[11]  Y. Xing,et al.  Ultrasonography Assessments of Optic Nerve Sheath Diameter as a Noninvasive and Dynamic Method of Detecting Changes in Intracranial Pressure , 2018, JAMA ophthalmology.

[12]  J. Webster,et al.  Invasive and noninvasive means of measuring intracranial pressure: a review , 2017, Physiological measurement.

[13]  D. Menon,et al.  Ultrasound non-invasive measurement of intracranial pressure in neurointensive care: A prospective observational study , 2017, PLoS medicine.

[14]  Odette A. Harris,et al.  Guidelines for the Management of Severe Traumatic Brain Injury, Fourth Edition , 2016, Neurosurgery.

[15]  S. Choi,et al.  Ultrasonographic optic nerve sheath diameter for predicting elevated intracranial pressure during laparoscopic surgery: a systematic review and meta-analysis , 2017, Surgical Endoscopy.

[16]  K. Egger,et al.  Enlarged Optic Nerve Sheath in Aneurysmal Subarachnoid Hemorrhage despite Normal Intracranial Pressure , 2016, Journal of neuroimaging : official journal of the American Society of Neuroimaging.

[17]  K. Min,et al.  Ultrasonography of the optic nerve sheath to assess intracranial pressure changes after ventriculo‐peritoneal shunt surgery in children with hydrocephalus: a prospective observational study , 2015, Anaesthesia.

[18]  H. J. Kim,et al.  Position does not affect the optic nerve sheath diameter during laparoscopy , 2015, Korean journal of anesthesiology.

[19]  Michael Y Woo,et al.  Sonography of the Optic Nerve Sheath Diameter for Detection of Raised Intracranial Pressure Compared to Computed Tomography , 2015, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[20]  Diederik Gommers,et al.  Ultrasonographic measured optic nerve sheath diameter as an accurate and quick monitor for changes in intracranial pressure. , 2015, Journal of neurosurgery.

[21]  Jai-hyun Hwang,et al.  Sonographic optic nerve sheath diameter as a surrogate measure for intracranial pressure in anesthetized patients in the Trendelenburg position , 2015, BMC Anesthesiology.

[22]  P. McBeth,et al.  Association Between Optic Nerve Sheath Diameter and Mortality in Patients with Severe Traumatic Brain Injury , 2014, Neurocritical Care.

[23]  H. Dupont,et al.  Estimation of optic nerve sheath diameter on an initial brain computed tomography scan can contribute prognostic information in traumatic brain injury patients , 2013, Critical Care.

[24]  J. Finnie Neuroinflammation: beneficial and detrimental effects after traumatic brain injury , 2013, Inflammopharmacology.

[25]  M. Kaps,et al.  Intra‐ and Interobsever Reliability of Sonographic Assessment of the Optic Nerve Sheath Diameter in Healthy Adults , 2012, Journal of neuroimaging : official journal of the American Society of Neuroimaging.

[26]  W. Lagrèze,et al.  Dependence of the optic nerve sheath diameter on acutely applied subarachnoidal pressure – an experimental ultrasound study , 2011, Acta ophthalmologica.

[27]  A. Kippin,et al.  Can Accurate Ultrasonographic Measurement of the Optic Nerve Sheath Diameter (a Non-Invasive Measure of Intracranial Pressure) be Taught to Novice Operators in a Single Training Session? , 2011, Anaesthesia and intensive care.

[28]  Barbara Pizzi,et al.  Reliability of Optic Nerve Ultrasound for the Evaluation of Patients with Spontaneous Intracranial Hemorrhage , 2009, Neurocritical care.

[29]  N. Miller,et al.  Papilledema revisited: is its pathophysiology really understood? , 2009, Clinical & experimental ophthalmology.

[30]  D. Benhamou,et al.  Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury , 2007, Intensive Care Medicine.