Optimal imaging for guiding TAVR: transesophageal or transthoracic echocardiography, or just fluoroscopy?

THE FOLLOWING iFORUM DEBATE FEATURES 3 VIEWPOINTS related to the most practical and effective imaging strategy for guiding transcatheter aortic valve replacement (TAVR). Kronzon, et al. provide evidence that enhanced analysis of abrtic valve anatomy and improved appreciation of complications mandate the use of transesophageal echocardiography as front-Line imaging modality for ALL patients undergoing TAVR. On the other hand, Saric and colleagues compare and contrast the approach of performing TAVR under transthoracic guidance. Lastly, Kasel and co-workers provide preliminary evidence that TAVR could be performed under fluoroscopic guidance without the need for additional imaging technique. Although the use of Less-intensive sedation or anesthesia might reduce the procedural time, we need more randomized data to establish the most cost-effective approach in guiding TAVR.

[1]  C. Macaya,et al.  Feasibility and safety of transfemoral implantation of Edwards SAPIEN XT prosthesis without balloon valvuloplasty in severe stenosis of native aortic valve , 2014, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[2]  T. Sundt,et al.  Correction: 2014 AHA/ACC guideline for the management of patients with valvular heart disease: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Journal of the American College of Cardiology (2014) 63 (2438-88)) , 2014 .

[3]  J. Dubois-Randé,et al.  Effect of local anesthetic management with conscious sedation in patients undergoing transcatheter aortic valve implantation. , 2013, The American journal of cardiology.

[4]  Cornelius Müller,et al.  Aortic regurgitation index defines severity of peri-prosthetic regurgitation and predicts outcome in patients after transcatheter aortic valve implantation. , 2012, Journal of the American College of Cardiology.

[5]  Thoralf M Sundt,et al.  2014 AHA/ACC guideline for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. , 2014, Journal of the American College of Cardiology.

[6]  R. Guyton,et al.  Comparison of transfemoral transcatheter aortic valve replacement performed in the catheterization laboratory (minimalist approach) versus hybrid operating room (standard approach): outcomes and cost analysis. , 2014, JACC. Cardiovascular interventions.

[7]  Georg Rose,et al.  2D/3D Registration of TEE Probe from Two Non-orthogonal C-Arm Directions , 2014, MICCAI.

[8]  M. Monaghan,et al.  How to assess aortic annular size before transcatheter aortic valve implantation (TAVI): the role of echocardiography compared with other imaging modalities , 2014, Heart.

[9]  P. Sengupta,et al.  Robot-assisted remote echocardiographic examination and teleconsultation: a randomized comparison of time to diagnosis with standard of care referral approach. , 2014, JACC. Cardiovascular imaging.

[10]  Shunichi Homma,et al.  Echocardiography-guided interventions. , 2009, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[11]  Gloria Tamborini,et al.  Feasibility and accuracy of 3DTEE versus CT for the evaluation of aortic valve annulus to left main ostium distance before transcatheter aortic valve implantation. , 2012, JACC. Cardiovascular imaging.

[12]  Thoralf M Sundt,et al.  2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. , 2014, Circulation.

[13]  A. Zangrillo,et al.  Anesthetic management for percutaneous aortic valve implantation: an overview of worldwide experiences , 2012, HSR proceedings in intensive care & cardiovascular anesthesia.

[14]  Assaf Bash,et al.  Percutaneous Transcatheter Implantation of an Aortic Valve Prosthesis for Calcific Aortic Stenosis: First Human Case Description , 2002, Circulation.

[15]  Duolao Wang,et al.  Local versus general anesthesia for transcatheter aortic valve implantation (TAVR) – systematic review and meta-analysis , 2014, BMC Medicine.

[16]  J. Rodés‐Cabau,et al.  Usefulness of Doppler echocardiography guidance during balloon aortic valvuloplasty for the treatment of congenital aortic stenosis. , 2008, International journal of cardiology.

[17]  S. Pocock,et al.  Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. , 2010, The New England journal of medicine.

[18]  Thoralf M Sundt,et al.  2014 AHA/ACC guideline for the management of patients with valvular heart disease: executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. , 2014, Journal of the American College of Cardiology.

[19]  A. Kastrati,et al.  Anatomic guided crossing of a stenotic aortic valve under fluoroscopy: "right cusp rule, part III". , 2015, JACC. Cardiovascular interventions.

[20]  E. Erdmann,et al.  Local versus general anesthesia for transfemoral aortic valve implantation , 2011, Clinical Research in Cardiology.

[21]  Adnan Kastrati,et al.  Fluoroscopy-guided aortic root imaging for TAVR: "follow the right cusp" rule. , 2013, JACC. Cardiovascular imaging.

[22]  A. Mügge,et al.  Long-term outcome of patients with moderate and severe prosthetic aortic valve regurgitation after transcatheter aortic valve implantation. , 2012, The American journal of cardiology.

[23]  A. Messori,et al.  Transcatheter aortic-valve implantation for aortic stenosis. , 2011, The New England journal of medicine.

[24]  T. Steigen,et al.  Transkateter aortaventilimplantasjon ved aortastenose , 2011 .

[25]  A. Kastrati,et al.  Standardized methodology for transfemoral transcatheter aortic valve replacement with the Edwards Sapien XT valve under fluoroscopy guidance. , 2014, The Journal of invasive cardiology.

[26]  Samin K. Sharma,et al.  Transthoracic echocardiography guidance for TAVR under monitored anesthesia care. , 2015, JACC. Cardiovascular imaging.

[27]  Jean-Louis Vanoverschelde,et al.  EAE/ASE recommendations for the use of echocardiography in new transcatheter interventions for valvular heart disease. , 2011, European heart journal.

[28]  A. Cordell,et al.  Accuracy of transesophageal echocardiography in preoperative determination of aortic anulus size during valve replacement. , 1997, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[29]  Sanjay Kaul,et al.  2012 ACCF/AATS/SCAI/STS expert consensus document on transcatheter aortic valve replacement. , 2012, Journal of the American College of Cardiology.

[30]  C. Becker,et al.  Transcutaneous aortic valve replacement with the Edwards SAPIEN XT and Medtronic CoreValve prosthesis under fluoroscopic guidance and local anaesthesia only , 2014, Heart.

[31]  T. Walther,et al.  Transfemoral Aortic Valve Implantation of Edwards SAPIEN XT Without Predilatation Is Feasible , 2014, Clinical cardiology.

[32]  H. Dodge,et al.  Quantitation of valvular insufficiency in man by angiocardiography. , 1963, American heart journal.

[33]  Adnan Kastrati,et al.  Standardized imaging for aortic annular sizing: implications for transcatheter valve selection. , 2013, JACC. Cardiovascular imaging.

[34]  K. Shimada,et al.  Diagnostic accuracy of transthoracic and transesophageal echocardiography for the diagnosis of bicuspid aortic valve: comparison with operative findings. , 2013, Osaka city medical journal.

[35]  Carlos Ruiz,et al.  Use of real time three-dimensional transesophageal echocardiography in intracardiac catheter based interventions. , 2009, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[36]  Eric Durand,et al.  Transfemoral aortic valve replacement with the Edwards SAPIEN and Edwards SAPIEN XT prosthesis using exclusively local anesthesia and fluoroscopic guidance: feasibility and 30-day outcomes. , 2012, JACC. Cardiovascular interventions.