An assessment of 25-hydroxyvitamin D measurements in comparability studies conducted by the Vitamin D Metabolites Quality Assurance Program.

BACKGROUND The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health Office of Dietary Supplements, established the first accuracy-based program for improving the comparability of vitamin D metabolite measurements, the Vitamin D Metabolites Quality Assurance Program. METHODS The study samples were human serum or plasma Standard Reference Materials (SRMs) with 25-hydroxyvitamin D values that were determined at NIST. Participants evaluated the materials using immunoassay (IA), liquid chromatography (LC) with mass spectrometric detection, and LC with ultraviolet absorbance detection. NIST evaluated the results for concordance within the participant community as well as trueness relative to the NIST value. RESULTS For the study materials that contain mostly 25-hydroxyvitamin D3 (25(OH)D3),the coefficient of variation (CV) for the participant results was consistently in the range from 7% to 19%, and the median values were biased high relative to the NIST values. However, for materials that contain significant concentrations of both 25-hydroxyvitamin D2 (25(OH)D2) and 25(OH)D3, the median IA results were biased lower than both the LC and the NIST values, and the CV was as high as 28%. The first interlaboratory comparison results for SRM 972a Vitamin D Metabolites in Human Serum are also reported. CONCLUSIONS Relatively large within-lab and between-lab variability hinders conclusive assessments of bias and accuracy.

[1]  M. Wheeler,et al.  Proficiency testing of 25-Hydroxyvitamin D (25-OHD) assays , 2010, The Journal of Steroid Biochemistry and Molecular Biology.

[2]  Christopher-John L Farrell,et al.  State-oftheArt oftheArt oftheArt theArt theArt Vitamin D Assays : A Comparison of Automated Immunoassays with Liquid Chromatography – Tandem Mass Spectrometry Methods , 2012 .

[3]  S. Wise,et al.  Development and certification of a standard reference material for vitamin D metabolites in human serum. , 2012, Analytical chemistry.

[4]  G. Carter,et al.  The anomalous behaviour of exogenous 25-hydroxyvitamin D in competitive binding assays , 2007, The Journal of Steroid Biochemistry and Molecular Biology.

[5]  A. Ponsonby,et al.  Variability in vitamin D assays impairs clinical assessment of vitamin D status , 2012, Internal medicine journal.

[6]  Paul Williams,et al.  State-of-the-art vitamin D assays: a comparison of automated immunoassays with liquid chromatography-tandem mass spectrometry methods. , 2012, Clinical chemistry.

[7]  M. Drezner,et al.  HPLC method for 25-hydroxyvitamin D measurement: comparison with contemporary assays. , 2006, Clinical chemistry.

[8]  N. Binkley,et al.  The C-3 epimer of 25-hydroxyvitamin D(3) is present in adult serum. , 2012, The Journal of clinical endocrinology and metabolism.

[9]  K. Phinney,et al.  Development of a candidate reference measurement procedure for the determination of 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry. , 2010, Analytical chemistry.

[10]  L. Thienpont,et al.  Full-scan mass spectral evidence for 3-epi-25-hydroxyvitamin D3 in serum of infants and adults , 2011, Clinical chemistry and laboratory medicine.

[11]  D. Wiebe,et al.  Current status of clinical 25-hydroxyvitamin D measurement: an assessment of between-laboratory agreement. , 2010, Clinica chimica acta; international journal of clinical chemistry.

[12]  Christine L. Taylor,et al.  Dietary Reference Intakes for Calcium and Vitamin D , 2016, Pediatric Clinical Practice Guidelines & Policies.

[13]  M. Ashwell,et al.  Measurement of 25-hydroxyvitamin D in the clinical laboratory: Current procedures, performance characteristics and limitations , 2010, Steroids.

[14]  K. Phinney,et al.  Development and comparison of three liquid chromatography-atmospheric pressure chemical ionization/mass spectrometry methods for determining vitamin D metabolites in human serum. , 2012, Journal of chromatography. A.

[15]  C. Pfeiffer,et al.  Isotope dilution ultra performance liquid chromatography-tandem mass spectrometry method for simultaneous measurement of 25-hydroxyvitamin D2, 25-hydroxyvitamin D3 and 3-epi-25-hydroxyvitamin D3 in human serum. , 2011, Clinica chimica acta; international journal of clinical chemistry.

[16]  Jane Schmidt Measurement of 25-hydroxyvitamin D revisited. , 2006, Clinical chemistry.

[17]  E. Hyppönen,et al.  Serum 25-hydroxyvitamin D measurement in a large population survey with statistical harmonization of assay variation to an international standard. , 2007, The Journal of clinical endocrinology and metabolism.

[18]  G. Carter 25-hydroxyvitamin D: a difficult analyte. , 2012, Clinical chemistry.

[19]  K. Michaëlsson,et al.  Determining Vitamin D Status: A Comparison between Commercially Available Assays , 2010, PloS one.

[20]  R. Habib,et al.  25-hydroxyvitamin D assay variations and impact on clinical decision making. , 2012, The Journal of clinical endocrinology and metabolism.

[21]  J. Berry,et al.  How accurate are assays for 25-hydroxyvitamin D? Data from the international vitamin D external quality assessment scheme. , 2004, Clinical chemistry.

[22]  Ravinder J. Singh,et al.  C-3 Epimers Can Account for a Significant Proportion of Total Circulating 25-hydroxyvitamin D in Infants, Complicating Accurate Measurement and Interpretation of Vitamin D Status , 2022 .

[23]  K. Inouye,et al.  C-3 Epimerization of Vitamin D3 Metabolites and Further Metabolism of C-3 Epimers , 2004, Journal of Biological Chemistry.

[24]  G. Carter 25-Hydroxyvitamin D assays: the quest for accuracy. , 2009, Clinical chemistry.

[25]  M. Bissell Accuracy of 6 Routine 25-Hydroxyvitamin D Assays: Influence of Vitamin D Binding Protein Concentration , 2013 .

[26]  M. Drezner,et al.  Assay variation confounds the diagnosis of hypovitaminosis D: a call for standardization. , 2004, The Journal of clinical endocrinology and metabolism.

[27]  Frederick G. Strathmann,et al.  3-epi-25 hydroxyvitamin D concentrations are not correlated with age in a cohort of infants and adults. , 2012, Clinica chimica acta; international journal of clinical chemistry.