Relative dosimetry using active matrix flat-panel imager (AMFPI) technology.

The first examination of the use of active matrix flat-panel arrays for dosimetry in radiotherapy is reported. Such arrays are under widespread development for diagnostic and radiotherapy imaging. In the current study, an array consisting of 512 x 512 pixels with a pixel pitch of 508 microm giving an area of 26 x 26 cm2 has been used. Each pixel consists of a light sensitive amorphous silicon (a-Si:H) photodiode coupled to an a-Si:H thin-film transistor. Data was obtained from the array using a dedicated electronics system allowing real-time data acquisition. In order to examine the potential of such arrays as quality assurance devices for radiotherapy beams, field profile data at photon energies of 6 and 15 MV were obtained as a function of field size and thickness of overlying absorbing material (solid water). Two detection configurations using the array were considered: a configuration (similar to the imaging configuration) in which an overlying phosphor screen is used to convert incident radiation to visible light photons which are detected by the photodiodes; and a configuration without the screen where radiation is directly sensed by the photodiodes. Compared to relative dosimetry data obtained with an ion chamber, data taken using the former configuration exhibited significant differences whereas data obtained using the latter configuration was generally found to be in close agreement. Basic signal properties, which are pertinent to dosimetry, have been investigated through measurements of individual pixel response for fluoroscopic and radiographic array operation. For signal levels acquired within the first 25% of pixel charge capacity, the degree of linear response with dose was found to be better than 99%. The independence of signal on dose rate was demonstrated by means of stability of pixel response over the range of dose rates allowed by the radiation source (80-400 MU/min). Finally, excellent long-term stability in pixel response, extending over a 2 month period, was observed.

[1]  K Doi,et al.  Studies of x-ray energy absorption and quantum noise properties of x-ray screens by use of Monte Carlo simulation. , 1984, Medical physics.

[2]  Larry E. Antonuk,et al.  Development of hydrogenated amorphous silicon sensors for high energy photon radiotherapy imaging , 1990 .

[3]  D. Convery,et al.  The generation of intensity-modulated fields for conformal radiotherapy by dynamic collimation , 1992 .

[4]  F. H. Attix,et al.  Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements. , 1992, Physics in medicine and biology.

[5]  F. H. Attix,et al.  Water-equivalent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical consideration. , 1992, Physics in medicine and biology.

[6]  J Yorkston,et al.  Demonstration of megavoltage and diagnostic x-ray imaging with hydrogenated amorphous silicon arrays. , 1992, Medical physics.

[7]  Weidong Huang,et al.  A data acquisition system for flat-panel imaging arrays , 1993 .

[8]  Larry E. Antonuk,et al.  Radiation response of amorphous silicon imaging arrays at diagnostic energies , 1994 .

[9]  Larry E. Antonuk,et al.  Radiation damage of amorphous silicon photodiode sensors , 1994 .

[10]  B. Heijmen,et al.  Portal dose measurement in radiotherapy using an electronic portal imaging device (EPID). , 1995, Physics in medicine and biology.

[11]  M C Kirby,et al.  The use of an electronic portal imaging device for exit dosimetry and quality control measurements. , 1995, International journal of radiation oncology, biology, physics.

[12]  Larry E. Antonuk,et al.  Large-area flat-panel amorphous silicon imagers , 1995, Medical Imaging.

[13]  Y. Zhu,et al.  Portal dosimetry using a liquid ion chamber matrix: dose response studies. , 1995, Medical physics.

[14]  R. Boellaard,et al.  The dose response relationship of a liquid-filled electronic portal imaging device. , 1996, Medical physics.

[15]  L. Antonuk,et al.  Radiation damage of amorphous silicon, thin-film, field-effect transistors. , 1996, Medical physics.

[16]  J Yorkston,et al.  Megavoltage imaging with a large-area, flat-panel, amorphous silicon imager. , 1996, International journal of radiation oncology, biology, physics.

[17]  J Yorkston,et al.  Empirical investigation of the signal performance of a high-resolution, indirect detection, active matrix flat-panel imager (AMFPI) for fluoroscopic and radiographic operation. , 1997, Medical physics.

[18]  J Yorkston,et al.  Empirical and theoretical investigation of the noise performance of indirect detection, active matrix flat-panel imagers (AMFPIs) for diagnostic radiology. , 1997, Medical physics.

[19]  I. Blevis,et al.  Digital radiology using active matrix readout of amorphous selenium: construction and evaluation of a prototype real-time detector. , 1997, Medical physics.

[20]  A L Boyer,et al.  Quality assurance for dynamic multileaf collimator modulated fields using a fast beam imaging system. , 1997, Medical physics.

[21]  Richard L. Weisfield,et al.  Amorphous Silicon Sensor Arrays for X-Ray and Document Imaging , 1997 .

[22]  A G Visser,et al.  Accurate portal dose measurement with a fluoroscopic electronic portal imaging device (EPID) for open and wedged beams and dynamic multileaf collimation. , 1998, Physics in medicine and biology.

[23]  J Yorkston,et al.  Initial performance evaluation of an indirect-detection, active matrix flat-panel imager (AMFPI) prototype for megavoltage imaging. , 1998, International journal of radiation oncology, biology, physics.

[24]  M Partridge,et al.  Independent verification using portal imaging of intensity-modulated beam delivery by the dynamic MLC technique. , 1998, Medical physics.

[25]  Larry E. Antonuk,et al.  Improved spatial resolution in flat-panel imaging systems , 1998, Medical Imaging.

[26]  B. Fallone,et al.  Preliminary study of a metal/a-Se-based portal detector. , 1998, Medical physics.

[27]  P. Munro,et al.  X-ray quantum limited portal imaging using amorphous silicon flat-panel arrays. , 1998, Medical physics.

[28]  Larry E. Antonuk,et al.  An asynchronous, pipelined, electronic acquisition system for Active Matrix Flat-Panel Imagers (AMFPIs) , 1999 .