Prospective Techniques for Magnetic Resonance Imaging–Guided Robot-Assisted Stereotactic Neurosurgery

Abstract Stereotactic neurosurgery involves a technique that can locate the brain targets using an external coordinate system. With the advancements of magnetic resonance imaging (MRI), numerous studies on frameless stereotaxy and MRI-guided/verified technique have been reported to improve the workflow and surgical outcomes. Intraoperative (intraop) MRI guidance in frameless techniques is an appealing method which could simplify workflow by reducing the coregistration errors in different imaging modalities and monitoring the surgical progress. Manually operated platforms thus emerge for MRI-guided frameless procedures. However, these procedures could still be complicated and time-consuming due to their intensive manual operation. To further simplify the procedure and enhance accuracy, robotics has been introduced. In this chapter, we review the state-of-the-art intraop MRI-guided robotic platforms for stereotactic neurosurgery. To improve surgical workflow and achieve greater clinical penetration, three key enabling techniques are discussed with emphasis on their current status, limitations, and future trends.

[1]  E. Spiegel,et al.  Stereotaxic Apparatus for Operations on the Human Brain. , 1947, Science.

[2]  Ehud Mendel,et al.  Current state-of-the-art and future perspectives of robotic technology in neurosurgery , 2014, Neurosurgical Review.

[3]  W. Tobler,et al.  Image-guided neurosurgery. , 1998, Surgical technology international.

[4]  G. Fichtinger,et al.  Development and Evaluation of an Actuated MRI-Compatible Robotic System for MRI-Guided Prostate Intervention , 2013, IEEE/ASME Transactions on Mechatronics.

[5]  Zion Tsz Ho Tse,et al.  An MR-Conditional High-Torque Pneumatic Stepper Motor for MRI-Guided and Robot-Assisted Intervention , 2014, Annals of Biomedical Engineering.

[6]  P. Reed Stereotactic neurosurgery , 2017, Neurosurgery clinics of North America.

[7]  Gregory S. Fischer,et al.  High-Field MRI-Compatible Needle Placement Robots for Prostate Interventions: Pneumatic and Piezoelectric Approaches , 2012 .

[8]  Robert J. Webster,et al.  Optimization of Curvilinear Needle Trajectories for Transforamenal Hippocampotomy , 2016, Operative neurosurgery.

[9]  E. Fonoff,et al.  An image correction protocol to reduce distortion for 3-T stereotactic MRI. , 2014, Neurosurgery.

[10]  Andreas Melzer,et al.  Wireless MR tracking of interventional devices using phase-field dithering and projection reconstruction. , 2014, Magnetic resonance imaging.

[11]  T. Fielding,et al.  An image-guided magnetic resonance-compatible surgical robot. , 2008, Neurosurgery.

[12]  Bejoy Thomas,et al.  Principles, techniques, and applications of T2*-based MR imaging and its special applications. , 2009, Radiographics : a review publication of the Radiological Society of North America, Inc.

[13]  Peter Metcalfe,et al.  MRI distortion: considerations for MRI based radiotherapy treatment planning , 2014, Australasian Physical & Engineering Sciences in Medicine.

[14]  Dan Stoianovici,et al.  MR Safe Robot, FDA Clearance, Safety and Feasibility of Prostate Biopsy Clinical Trial , 2017, IEEE/ASME Transactions on Mechatronics.

[15]  B Gino Fallone,et al.  Characterization, prediction, and correction of geometric distortion in 3 T MR images. , 2007, Medical physics.

[16]  G A Coutts,et al.  Integrated and interactive position tracking and imaging of interventional tools and internal devices using small fiducial receiver coils , 1998, Magnetic resonance in medicine.

[17]  Jaydev P. Desai,et al.  Design, development, and evaluation of an MRI-guided SMA spring-actuated neurosurgical robot , 2015, Int. J. Robotics Res..

[18]  J. Henderson,et al.  The application accuracy of a skull-mounted trajectory guide system for image-guided functional neurosurgery , 2004, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[19]  Walter A. Hall,et al.  MRI Guidance of Minimally Invasive Cranial Applications , 2011 .

[20]  Gregory S. Fischer,et al.  Mechanical validation of an MRI compatible stereotactic neurosurgery robot in preparation for pre-clinical trials , 2017, 2017 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS).

[21]  K Chinzei,et al.  Towards MRI guided surgical manipulator. , 2001, Medical science monitor : international medical journal of experimental and clinical research.

[22]  Jorge Gonzalez-Martinez,et al.  Robot-Assisted Stereotactic Laser Ablation in Medically Intractable Epilepsy: Operative Technique , 2014, Neurosurgery.

[23]  C. Nimsky,et al.  Intraoperative compensation for brain shift. , 2001, Surgical neurology.

[24]  Justin P. Haldar,et al.  Co-registration and distortion correction of diffusion and anatomical images based on inverse contrast normalization , 2015, NeuroImage.

[25]  P. Krack,et al.  Surgical implantation of STN-DBS leads using intraoperative MRI guidance: technique, accuracy, and clinical benefit at 1-year follow-up , 2015, Acta Neurochirurgica.

[26]  Kit-Hang Lee,et al.  Compact Design of a Hydraulic Driving Robot for Intraoperative MRI-Guided Bilateral Stereotactic Neurosurgery , 2018, IEEE Robotics and Automation Letters.

[27]  Mark R. Cutkosky,et al.  Autonomous Real-Time Interventional Scan Plane Control With a 3-D Shape-Sensing Needle , 2014, IEEE Transactions on Medical Imaging.

[28]  H Iseki,et al.  Development of an MRI-compatible needle insertion manipulator for stereotactic neurosurgery. , 1995, Journal of image guided surgery.

[29]  Sebastien Crouzet,et al.  Robotic single‐port transumbilical surgery in humans: initial report , 2009, BJU international.

[30]  J. Schwalb,et al.  Intraoperative MRI for deep brain stimulation lead placement in Parkinson’s disease: 1 year motor and neuropsychological outcomes , 2016, Journal of Neurology.

[31]  Jaydev P. Desai,et al.  Toward the Development of a Flexible Mesoscale MRI-Compatible Neurosurgical Continuum Robot , 2017, IEEE Transactions on Robotics.

[32]  Steve B Jiang,et al.  Implementation and evaluation of various demons deformable image registration algorithms on a GPU. , 2010, Physics in medicine and biology.

[33]  Tobias Schaeffter,et al.  In vivo safe catheter visualization and slice tracking using an optically detunable resonant marker , 2004, Magnetic resonance in medicine.

[34]  C. Avezaat,et al.  Safety and efficacy of frameless and frame-based intracranial biopsy techniques , 2008, Acta Neurochirurgica.

[35]  C J Bakker,et al.  Heating Around Intravascular Guidewires by Resonating RF Waves , 2000, Journal of magnetic resonance imaging : JMRI.

[36]  M. Hardenbrook,et al.  Clinical Acceptance and Accuracy Assessment of Spinal Implants Guided With SpineAssist Surgical Robot: Retrospective Study , 2010, Spine.

[37]  Paul S. Larson,et al.  Interventional MRI-guided deep brain stimulation in pediatric dystonia: first experience with the ClearPoint system. , 2014, Journal of neurosurgery. Pediatrics.

[38]  Ron Kikinis,et al.  Precise Evaluation of Positioning Repeatability of MR-Compatible Manipulator Inside MRI , 2004, MICCAI.

[39]  J. Henderson,et al.  Frameless stereotaxy using bone fiducial markers for deep brain stimulation. , 2005, Journal of neurosurgery.

[40]  G. Ferrigno,et al.  Review of Robotic Technology for Stereotactic Neurosurgery , 2015, IEEE Reviews in Biomedical Engineering.

[41]  H. Berkenstadt,et al.  Novel, Compact, Intraoperative Magnetic Resonance Imaging-guided System for Conventional Neurosurgical Operating Rooms , 2001, Neurosurgery.

[42]  N. Cheshire,et al.  Clinical applications of robotic technology in vascular and endovascular surgery. , 2011, Journal of vascular surgery.

[43]  G.R. Sutherland,et al.  Integrating an Image-Guided Robot with Intraoperative MRI , 2008, IEEE Engineering in Medicine and Biology Magazine.

[44]  S. Souza,et al.  Real‐time position monitoring of invasive devices using magnetic resonance , 1993, Magnetic resonance in medicine.

[45]  J S Lewin,et al.  Intraoperative magnetic resonance image guidance in neurosurgery , 2000, Journal of magnetic resonance imaging : JMRI.

[46]  Shaun P. Salisbury,et al.  Development of an MRI-Compatible, Compact, Rotary-Linear Piezoworm Actuator , 2015 .

[47]  Vipin Chaudhary,et al.  Intraoperative brain shift prediction using a 3D inhomogeneous patient-specific finite element model. , 2007, Journal of neurosurgery.

[48]  N. Voets,et al.  Better object recognition and naming outcome with MRI‐guided stereotactic laser amygdalohippocampotomy for temporal lobe epilepsy , 2015, Epilepsia.

[49]  M Bock,et al.  Targeted‐HASTE imaging with automated device tracking for MR‐guided needle interventions in closed‐bore MR systems , 2006, Magnetic resonance in medicine.

[50]  Tobias Schaeffter,et al.  MR‐guided breast biopsy using an active marker: A phantom study , 2006, Journal of magnetic resonance imaging : JMRI.

[51]  Yun Chao,et al.  Design and Optimization Analysis of Open-MRI Compatibile Robot for Neurosurgery , 2008, 2008 2nd International Conference on Bioinformatics and Biomedical Engineering.

[52]  Paul S. Larson,et al.  203 Application Accuracy of a Second Generation Interventional MRI Stereotactic PlatformInitial Experience in 101 DBS Electrode Implantations , 2013 .

[53]  Ron Kikinis,et al.  MR Compatibility of Mechatronic Devices: Design Criteria , 1999, MICCAI.

[54]  D. Louw,et al.  Surgical Robotics: A Review and Neurosurgical Prototype Development , 2004, Neurosurgery.

[55]  Andrew A. Goldenberg,et al.  Design and Control of a Novel Hydraulically/Pneumatically Actuated Robotic System for MRI-Guided Neurosurgery , 2008 .

[56]  R. Maciunas,et al.  The application accuracy of stereotactic frames. , 1994, Neurosurgery.

[57]  Hao Su,et al.  Robotic System for MRI-Guided Stereotactic Neurosurgery , 2015, IEEE Transactions on Biomedical Engineering.

[58]  M. Hariz,et al.  Variability of the subthalamic nucleus: The case for direct MRI guided targeting , 2007, British journal of neurosurgery.

[59]  Mitchel S. Berger,et al.  Novel Platform for MRI-Guided Convection-Enhanced Delivery of Therapeutics: Preclinical Validation in Nonhuman Primate Brain , 2011, Stereotactic and Functional Neurosurgery.

[60]  R. Price The advantages of frameless stereotactic biopsy over frame-based biopsy , 2003, British journal of neurosurgery.

[61]  G. Sutherland,et al.  Advanced cranial navigation. , 2013, Neurosurgery.

[62]  L. Lunsford,et al.  Intraoperative imaging with a therapeutic computed tomographic scanner. , 1984, Neurosurgery.

[63]  A. Patriciu,et al.  A New Type of Motor: Pneumatic Step Motor , 2007, IEEE/ASME Transactions on Mechatronics.

[64]  R. Kikinis,et al.  Development and implementation of intraoperative magnetic resonance imaging and its neurosurgical applications. , 1997, Neurosurgery.

[65]  Dan Stoianovici,et al.  MR Safe Robot Assisted Needle Access of the Brain: Preclinical Study , 2018, J. Medical Robotics Res..

[66]  Jaimie M. Henderson,et al.  Frameless Localization for Functional Neurosurgical Procedures: A Preliminary Accuracy Study , 2004, Stereotactic and Functional Neurosurgery.

[67]  Alireza Mehrtash,et al.  Real‐time active MR‐tracking of metallic stylets in MR‐guided radiation therapy , 2015, Magnetic resonance in medicine.

[68]  Garnette R. Sutherland,et al.  Why Robots Entered Neurosurgery , 2016 .

[69]  E. Leuthardt,et al.  The role of laser interstitial thermal therapy in enhancing progression-free survival of difficult-to-access high-grade gliomas: a multicenter study , 2014, Cancer medicine.

[70]  Zion Tsz Ho Tse,et al.  A 10-mm MR-Conditional Unidirectional Pneumatic Stepper Motor , 2015, IEEE/ASME Transactions on Mechatronics.

[71]  S. Strother,et al.  Quantitative Comparisons of Image Registration Techniques Based on High‐Resolution MRI of the Brain , 1994, Journal of computer assisted tomography.

[72]  Ken Masamune,et al.  Micro-grasping Forceps Manipulator for MR-Guided Neurosurgery , 2002, MICCAI.

[73]  Jens Frahm,et al.  Real‐time MRI at a resolution of 20 ms , 2010, NMR in biomedicine.

[74]  Yi Wang,et al.  MRI compatibility evaluation of a piezoelectric actuator system for a neural interventional robot , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[75]  Robert Trampel,et al.  Navigation concepts for MR image‐guided interventions , 2008, Journal of magnetic resonance imaging : JMRI.

[76]  Olivier Clatz,et al.  Non-rigid alignment of pre-operative MRI, fMRI, and DT-MRI with intra-operative MRI for enhanced visualization and navigation in image-guided neurosurgery , 2007, NeuroImage.

[77]  J. Heiss,et al.  Accuracy of direct magnetic resonance imaging-guided placement of drug infusion cannulae. , 2015, Journal of neurosurgery.

[78]  Ken Masamune,et al.  MR-Safe Pneumatic Rotation Stepping Actuator , 2012, J. Robotics Mechatronics.

[79]  Deming Wang,et al.  Geometric distortion in clinical MRI systems Part I: evaluation using a 3D phantom. , 2004, Magnetic resonance imaging.

[80]  Eric C Leuthardt,et al.  Magnetic Resonance Imaging-Guided Focused Laser Interstitial Thermal Therapy for Subinsular Metastatic Adenocarcinoma: Technical Case Report , 2012, Neurosurgery.

[81]  Nobuhiko Hata,et al.  MR Compatible Surgical Assist Robot: System Integration and Preliminary Feasibility Study , 2000, MICCAI.

[82]  Wayne Luk,et al.  MRI-based visual and haptic catheter feedback: simulating a novel system's contribution to efficient and safe MRI-guided cardiac electrophysiology procedures , 2014, Journal of Cardiovascular Magnetic Resonance.

[83]  Hiroshi Iseki,et al.  Endoscope Manipulator for Trans-nasal Neurosurgery, Optimized for and Compatible to Vertical Field Open MRI , 2002, MICCAI.

[84]  Eric J. Barth,et al.  Design, Additive Manufacture, and Control of a Pneumatic MR-Compatible Needle Driver , 2016, IEEE Transactions on Robotics.

[85]  Garnette R. Sutherland,et al.  NeuroArm: an MR compatible robot for microsurgery , 2003, CARS.

[86]  Jaydev P. Desai,et al.  New Actuation Mechanism for Actively Cooled SMA Springs in a Neurosurgical Robot , 2017, IEEE Transactions on Robotics.

[87]  Daniel Rueckert,et al.  Distortion Correction in Fetal EPI Using Non-Rigid Registration With a Laplacian Constraint , 2016, IEEE Transactions on Medical Imaging.

[88]  S. Gill,et al.  MAGNETIC RESONANCE IMAGING‐DIRECTED METHOD FOR FUNCTIONAL NEUROSURGERY USING IMPLANTABLE GUIDE TUBES , 2007, Neurosurgery.

[89]  Alastair J. Martin,et al.  Comparison of Deep Brain Stimulation Lead Targeting Accuracy and Procedure Duration between 1.5- and 3-Tesla Interventional Magnetic Resonance Imaging Systems: An Initial 12-Month Experience , 2016, Stereotactic and Functional Neurosurgery.

[90]  Wayne Luk,et al.  FPGA-based acceleration of MRI registration: an enabling technique for improving MRI-guided cardiac therapy , 2014, Journal of Cardiovascular Magnetic Resonance.

[91]  M. Jahanshahi,et al.  MRI-guided STN DBS in Parkinson's disease without microelectrode recording: efficacy and safety , 2010, Journal of Neurology, Neurosurgery & Psychiatry.

[92]  D. Caleb Rucker,et al.  A MRI-guided concentric tube continuum robot with piezoelectric actuation: A feasibility study , 2012, 2012 IEEE International Conference on Robotics and Automation.

[93]  A. Sloan,et al.  Monteris AXiiiS Stereotactic Miniframe for Intracranial Biopsy: Precision, Feasibility, and Ease of Use , 2015, Operative neurosurgery.

[94]  James S. Duncan,et al.  Model-driven brain shift compensation , 2002, Medical Image Anal..

[95]  Sanju Lama,et al.  Robotics in the neurosurgical treatment of glioma , 2015, Surgical neurology international.