Abstract Three-dimensional parametric neutronics calculations using the Monte Carlo code MCNP-4C have been performed for a DEMO-type reactor based on the Helium-Cooled Lithium-Lead (HCLL) blanket. The aim of the analysis was to minimize the radial blanket thickness, while ensuring tritium self-sufficiency and to assess the shielding performance of the reactor in terms of the radiation loads to the super-conducting toroidal field (TF) coils. It was found that tritium self-sufficiency can be achieved with a breeder zone thickness reduced to no more than 55 cm at a 6Li enrichment of 90%. Assuming a 6Li enrichment of 60%, a breeder zone thickness of 60 cm is required to achieve the target TBR of 1.10 which is assumed to be sufficient to cover potential tritium losses and uncertainties. With regard to the shielding performance it was found that the design limits for the radiation loads to the TF-coil can be met with radial blanket thicknesses of 75 cm, 60 cm and 55 cm utilizing a two-component shield of Eurofer steel and tungsten carbide between the breeder zone and the vacuum vessel. The blanket variants with larger radial breeder zone show better shielding performances due to the reduced Eurofer shielding material acting as gamma radiation emitter in between the breeder zone and the vacuum vessel. In particular the radiation dose absorbed in the Epoxy insulator was shown to be the most critical quantity in this regard.