Implementation of Automated Blood Culture With Quality Assurance in a Resource-Limited Setting

Background: Blood cultures (BC) have a high clinical relevance and are a priority specimen for surveillance of antimicrobial resistance. Manual BC are still most frequently used in resource-limited settings. Data on automated BC performance in Africa are scarce. We implemented automated BC at a surveillance site of the African Network for improved Diagnostics, Epidemiology and Management of Common Infectious Agents (ANDEMIA). Methods: Between June 2017 and January 2018, pairs of automated BC (BacT/ALERT®FA Plus) and manual BC (brain-heart infusion broth) were compared at a University hospital in Bouaké, Côte d'Ivoire. BC were inoculated each with a target blood volume of 10 ml from the same venipuncture. Automated BC were incubated for up to 5 days, manual BC for up to 10 days. Terminal subcultures were performed for manual BC only. The two systems were compared regarding yield, contamination, and turnaround time. For quality assurance, isolates were retested in a German routine microbiological laboratory. Results: BC sampling was increased from on average 24 BC to 63 BC per month. A total of 337 matched pairs of BC were included. Automated BC was positive in 36.5%, manual BC in 24.0% (p-value < 0.01), proportion of contamination was 47.9 and 43.8%, respectively (p-value = 1.0). Turnaround time of positive BC was shortened by 2.5 days with automated compared to manual BC (p < 0.01). Most common detected pathogens in both systems were Klebsiella spp. (26.0%) and Staphylococcus aureus (18.2%). Most contaminants were members of the skin flora. Retesting of 162 isolates was concordant in 79.6% on family level. Conclusions: Implementing automated BC in a resource-limited setting is possible and improves microbiological diagnostic performance. Automated BC increased yield and shortened turnaround times. Regular training and mentorship of clinicians has to be intensified to increase number and quality of BC. Pre-analytical training to improve diagnostic stewardship is essential when implementing a new microbiological method. Retesting highlighted that manual identification and antimicrobial susceptibility testing can be of good quality and sustainable. The implementation of automated tools should be decided individually according to economic considerations, number of samples, stable supply chain of consumables, and technical sustainability.

[1]  S. Becker,et al.  High prevalence of ESBL-producing Klebsiella pneumoniae in clinical samples from central Côte d'Ivoire. , 2019, International journal of infectious diseases : IJID : official publication of the International Society for Infectious Diseases.

[2]  M. Semret,et al.  Diagnostic Bacteriology in District Hospitals in Sub-Saharan Africa: At the Forefront of the Containment of Antimicrobial Resistance , 2019, Front. Med..

[3]  T. Wangrangsimakul,et al.  Time to switch from CLSI to EUCAST? A Southeast Asian perspective , 2019, Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases.

[4]  S. Ombelet,et al.  Best Practices of Blood Cultures in Low- and Middle-Income Countries , 2019, Front. Med..

[5]  P. Newton,et al.  Defining System Requirements for Simplified Blood Culture to Enable Widespread Use in Resource-Limited Settings , 2019, Diagnostics.

[6]  S. Ombelet,et al.  Clinical bacteriology in low-resource settings: today's solutions. , 2018, The Lancet. Infectious diseases.

[7]  Gilbert GREUB,et al.  Internal quality assurance in diagnostic microbiology: A simple approach for insightful data , 2017, PloS one.

[8]  M. Delgado-Rodríguez,et al.  Systematic review and meta-analysis. , 2017, Medicina intensiva.

[9]  J Jacobs,et al.  Implementation of quality management for clinical bacteriology in low-resource settings. , 2017, Clinical microbiology and infection : the official publication of the European Society of Clinical Microbiology and Infectious Diseases.

[10]  Appiah-Korang Labi,et al.  Trends in paediatric and adult bloodstream infections at a Ghanaian referral hospital: a retrospective study , 2016, Annals of Clinical Microbiology and Antimicrobials.

[11]  Chao Lu,et al.  Retrospective study , 2016, Medicine.

[12]  A. Whitelaw,et al.  Time for a culture change? Suboptimal compliance with blood culture standards at a district hospital in Cape Town. , 2015, South African medical journal = Suid-Afrikaanse tydskrif vir geneeskunde.

[13]  I. Bogoch,et al.  Epidemiology of community-onset bloodstream infections in Bouaké, central Côte d’Ivoire , 2015, New microbes and new infections.

[14]  Marc Mendelson,et al.  The World Health Organization Global Action Plan for antimicrobial resistance. , 2015, South African medical journal = Suid-Afrikaanse tydskrif vir geneeskunde.

[15]  M. Weinstein,et al.  Controlled Clinical Comparison of BacT/Alert FA Plus and FN Plus Blood Culture Media with BacT/Alert FA and FN Blood Culture Media , 2013, Journal of Clinical Microbiology.

[16]  J. Crump,et al.  Community-acquired bloodstream infections in Africa: a systematic review and meta-analysis. , 2010, The Lancet. Infectious diseases.

[17]  M. Mohamed,et al.  Prevalence of microbial pathogens in blood cultures: an etiological and histopathological study , 2010 .

[18]  V. Rotimi,et al.  Comparative Evaluation of BacT/ALERT 3D and BACTEC Systems for the Recovery of Pathogens Causing Bloodstream Infections , 2006, Medical Principles and Practice.

[19]  W. Harmsen,et al.  Clinical comparison of the isolator and BacT/Alert aerobic blood culture systems , 1995, Journal of clinical microbiology.

[20]  R. Auckenthaler,et al.  Comparison of BacT/Alert with Signal blood culture system , 1995, Journal of clinical microbiology.

[21]  R. Fairbrother Blood cultures. , 1949, The Practitioner.