A simplified method for assessing the ductile behaviour of stud connectors in composite beams with high strength concrete slab

Abstract Local connection shear failure in the absence of adequate connection ductility can reduce steel and concrete composite element bending resistance. For these elements, Eurocode 4 contains design rules and criteria for checking that implicitly prevent early connection rupture, by limiting the value of the parameters influencing maximum slip capacity. Such indirect ductility checks can, however, only be applied within the constraints of their formulation hypotheses, such as material strength as specified in the document for instance. The use of high strength concrete substantially changes the ratio between maximum slip requirement and connection deformation capacity and demands direct connection ductility checking. This paper identifies the magnitudes affecting maximum slip requirement and suggests a simplified assessment method. The method, having general application, enables assessing connection efficiency to bending collapse of the composite beams and is particularly useful at the initial structure design stage as no demanding sophisticated analysis is required.

[1]  J M Aribert,et al.  MODELE DE CALCUL ELASTO-PLASTIQUE DE POUTRES MIXTES A CONNEXION PARTIELLE , 1982 .

[2]  D. Oehlers,et al.  Partial interaction in composite steel and concrete beams with full shear connection , 1997 .

[3]  R P Johnson,et al.  PARTIAL SHEAR CONNECTION IN COMPOSITE BEAMS FOR BUILDINGS. , 1991 .

[4]  D. Oehlers,et al.  The shear stiffness of stud shear connections in composite beams , 1986 .

[5]  J M Aribert ETUDE CRITIQUE PAR VOIE NUMERIQUE DE LA METHODE PROPOSEE DANS L'EUROCODE 4 POUR LE DIMENSIONNEMENT DES POUTRES MIXTES ACIER-BETON A CONNEXION PARTIELLE , 1988 .

[6]  K. F. Chung,et al.  Composite column design to Eurocode 4 : based on DD ENV 1994-1-1: 1994 Eurocode 4: design of composite steel and concrete structures: part 1.1: general rules and rules for buildings , 1994 .

[7]  Mark A. Bradford,et al.  Composite Steel and Concrete Structural Members: Fundamental Behaviour , 1995 .

[8]  R. P. Johnson,et al.  PARTIAL-INTERACTION DESIGN OF COMPOSITE BEAMS , 1975 .

[9]  L. An,et al.  Push-out tests on studs in high strength and normal strength concrete , 1996 .

[10]  Zdenek P. Bazant,et al.  COMPOUND SIZE EFFECT IN COMPOSITE BEAMS WITH SOFTENING CONNECTORS: I: ENERGY APPROACH , 1999 .

[11]  Tateo Kajita,et al.  Elastic-plastic analysis of composite beams with incomplete interaction by finite element method , 1981 .

[12]  Jan L. Vítek,et al.  Compound Size Effect in Composite Beams with Softening Connectors. II: Differential Equations and Behavior , 1999 .

[13]  Sandra Bullo,et al.  THE LOAD-BEARING CAPACITY OF STEEL-HPC COMPOSITE BEAMS , 1997 .

[14]  Deric J. Oehlers,et al.  Composite Beams with Limited-Slip-Capacity Shear Connectors , 1995 .