A new and practical ε-NTU correlation for the humidification process under different Lewis number

Abstract The main objective of this article is to present a new and practical correlation associating the effectiveness (e) with its number of transfer unit (NTU) and vice versa of the humidification process. This correlation is featured by its simplicity in use and has non-iterative procedure to implement as the traditional published correlations in the literature. The new correlation can predict the thermal performance/design of the humidifier at different Lewis numbers (both unit and non-unit) with a reasonable accuracy. General integral equation, which is similar to that of Merkel equation, is developed and used in the present humidifier simulation model. The validity of the new correlations was tested against the available experimental and numerical data reported in literature for an industrial air humidifier. In addition, the comparison was conducted with the traditional numerical model at different Lewis numbers. The simulated results of the present correlation show a good agreement with those obtained from the experimental work within 10% accuracy. The main benefits of this new correlation are: (1) its simplicity to be implemented through simple calculations of input parameters and (2) it provides helpful guidelines for developing of humidification-dehumidification HDH desalination cycle simulation program.

[1]  Dominique Marchio,et al.  Simplified model for indirect-contact evaporative cooling-tower behaviour , 2004 .

[2]  K. Srithar,et al.  Energy and exergy analysis for a humidification–dehumidification desalination system integrated with multiple inserts , 2015 .

[3]  Adel M. Abdel Dayem,et al.  Experimental and numerical investigation of humidification/dehumidification solar water desalination systems , 2009 .

[4]  S. Deng,et al.  Analytical solutions for evaluating the thermal performances of wet air cooling coils under both unit and non-unit Lewis Factors , 2010 .

[5]  Anthony M. Jacobi,et al.  Air-side data interpretation and performance analysis for heat exchangers with simultaneous heat and mass transfer: Wet and frosted surfaces , 2005 .

[6]  M. Khamis Mansour,et al.  Innovative correlation for calculating thermal performance of counterflow wet-cooling tower , 2014 .

[7]  Swellam W. Sharshir,et al.  Mathematical and experimental investigation of a solar humidification–dehumidification desalination unit , 2015 .

[8]  Camilo A. Arancibia-Bulnes,et al.  Water desalination by air humidification: Mathematical model and experimental study , 2012 .

[9]  J. R. Selman,et al.  Solar desalination with a humidification-dehumidification cycle: mathematical modeling of the unit , 2003 .

[10]  Hisham Ettouney,et al.  Design and analysis of humidification dehumidification desalination process , 2005 .

[11]  Hisham Ettouney,et al.  Low temperature humidification dehumidification desalination process , 2006 .

[12]  Ri-Hua Xiong,et al.  A mathematical model for a thermally coupled humidification–dehumidification desalination process , 2006 .

[13]  J. W. Ramsey,et al.  Thermal Environmental Engineering , 1970 .