MEMS Biosensors and COVID-19: Missed Opportunity
暂无分享,去创建一个
[1] M. Calleja,et al. Biosensors Based on Nanomechanical Systems , 2013 .
[2] R. Fumagalli,et al. Detection and quantification of SARS-CoV-2 by droplet digital PCR in real-time PCR negative nasopharyngeal swabs from suspected COVID-19 patients , 2020, PloS one.
[3] Anthony P F Turner,et al. Biosensors: sense and sensibility. , 2013, Chemical Society reviews.
[4] Jane Ru Choi. Development of Point-of-Care Biosensors for COVID-19 , 2020, Frontiers in Chemistry.
[5] Daeui Park,et al. Rapid Detection of COVID-19 Causative Virus (SARS-CoV-2) in Human Nasopharyngeal Swab Specimens Using Field-Effect Transistor-Based Biosensor , 2020, ACS nano.
[6] Min Kang,et al. SARS-CoV-2 Viral Load in Upper Respiratory Specimens of Infected Patients , 2020, The New England journal of medicine.
[7] Lukas P. M. Kremer,et al. A colorimetric RT-LAMP assay and LAMP-sequencing for detecting SARS-CoV-2 RNA in clinical samples , 2020, Science Translational Medicine.
[8] Blake N Johnson,et al. Biosensor-based microRNA detection: techniques, design, performance, and challenges. , 2014, The Analyst.
[9] Raymond Mariella,et al. Sample preparation: the weak link in microfluidics-based biodetection , 2008, Biomedical microdevices.
[10] G. Rosano,et al. Implantable devices for heart failure monitoring: the CardioMEMS™ system , 2019, European heart journal supplements : journal of the European Society of Cardiology.
[11] M. Grattarola,et al. Micromechanical cantilever-based biosensors , 2001 .
[12] Ibon Santiago,et al. Trends and Innovations in Biosensors for COVID‐19 Mass Testing , 2020, Chembiochem : a European journal of chemical biology.
[13] M. Kersaudy-Kerhoas,et al. Microfluidic blood plasma separation for medical diagnostics: is it worth it? , 2016, Lab on a chip.
[14] S. Manalis,et al. Micromechanical detection of proteins using aptamer-based receptor molecules. , 2004, Analytical chemistry.
[15] Quanyi Wang,et al. Viral load of SARS-CoV-2 in clinical samples , 2020, The Lancet Infectious Diseases.
[16] M. Hegner,et al. Effect of non-specific species competition from total RNA on the static mode hybridization response of nanomechanical assays of oligonucleotides. , 2014, Nanotechnology.
[17] C. Vieu,et al. Arrays of nanoelectromechanical biosensors functionalized by microcontact printing , 2012, Nanotechnology.
[18] Marc Madou,et al. Scaling issues in chemical and biological sensors , 2003, Proc. IEEE.
[19] Yoon-Seok Chung,et al. Viral Load Kinetics of SARS-CoV-2 Infection in First Two Patients in Korea , 2020, Journal of Korean medical science.
[20] H. Mao,et al. Detecting the Coronavirus (COVID-19) , 2020, ACS sensors.
[21] Liviu Nicu,et al. Biosensors and tools for surface functionalization from the macro- to the nanoscale: The way forward , 2008 .
[22] N. Anderson,et al. The Human Plasma Proteome: History, Character, and Diagnostic Prospects , 2003, Molecular & Cellular Proteomics.
[23] K Dheda,et al. Real-time RT-PCR normalisation; strategies and considerations , 2005, Genes and Immunity.
[24] Peidong Wang,et al. An automated integrated platform for rapid and sensitive multiplexed protein profiling using human saliva samples. , 2014, Lab on a chip.
[25] Luke P. Lee,et al. Self-powered integrated microfluidic point-of-care low-cost enabling (SIMPLE) chip , 2017, Science Advances.
[26] Harold G. Craighead,et al. Virus detection using nanoelectromechanical devices , 2004 .
[27] M. Roukes,et al. Ultra-sensitive NEMS-based cantilevers for sensing, scanned probe and very high-frequency applications. , 2007, Nature nanotechnology.
[28] Matthew Osborne,et al. Diagnosing COVID-19: The Disease and Tools for Detection , 2020, ACS nano.
[29] Vinayak P. Dravid,et al. Microcantilever resonance-based DNA detection with nanoparticle probes , 2003 .
[30] Francesca Campabadal,et al. Ultrasensitive mass sensor fully integrated with complementary metal-oxide-semiconductor circuitry , 2005 .
[31] M. Roukes,et al. Comparative advantages of mechanical biosensors. , 2011, Nature nanotechnology.
[32] Jan Lichtenberg,et al. Sample pretreatment on microfabricated devices. , 2002, Talanta.
[33] Z. Memish,et al. Diagnosis of SARS-CoV-2 infection based on CT scan vs RT-PCR: reflecting on experience from MERS-CoV , 2020, Journal of Hospital Infection.
[34] Seung Jun Oh,et al. An integrated rotary microfluidic system with DNA extraction, loop-mediated isothermal amplification, and lateral flow strip based detection for point-of-care pathogen diagnostics. , 2017, Biosensors & bioelectronics.
[35] Nigel Beard,et al. Dealing with real samples: sample pre-treatment in microfluidic systems. , 2003, Lab on a chip.
[36] C. Chin,et al. Lab-ona-chip devices for global health : Past studies and future opportunities , 2006 .
[37] Hai-Feng Ji,et al. Detection of feline coronavirus using microcantilever sensors , 2006, Measurement science & technology.
[38] Andrew St John,et al. Existing and Emerging Technologies for Point-of-Care Testing. , 2014, The Clinical biochemist. Reviews.
[39] Raj Mutharasan,et al. Sample preparation-free, real-time detection of microRNA in human serum using piezoelectric cantilever biosensors at attomole level. , 2012, Analytical chemistry.
[40] A. Hassibi,et al. On scaling laws of biosensors: A stochastic approach , 2009 .
[41] L. Gervais,et al. Microfluidic Chips for Point‐of‐Care Immunodiagnostics , 2011, Advanced materials.
[42] Erno Lindner,et al. Medical Sensors for the Diagnosis and Management of Disease: The Physician Perspective. , 2017, ACS sensors.
[43] M. Mauro,et al. Comparison of plasma extracellular RNA isolation kits reveals kit-dependent biases. , 2015, BioTechniques.
[44] Liviu Nicu,et al. Micromachined piezoelectric membranes with high nominal quality factors in newtonian liquid media : A Lamb's model validation at the microscale , 2007 .
[45] Xuexin Duan,et al. Quantification of the affinities and kinetics of protein interactions using silicon nanowire biosensors. , 2012, Nature nanotechnology.
[46] Thomas Thundat,et al. Glucose biosensor based on the microcantilever. , 2004, Analytical chemistry.
[47] Kristen L. Helton,et al. Microfluidic Overview of Global Health Issues Microfluidic Diagnostic Technologies for Global Public Health , 2006 .
[48] Pei-Chi Chen,et al. High sensitivity cardiac troponin I detection in physiological environment using AlGaN/GaN High Electron Mobility Transistor (HEMT) Biosensors. , 2018, Biosensors & bioelectronics.
[49] Julian Gordon,et al. Analytical sensitivity limits for lateral flow immunoassays. , 2008, Clinical chemistry.
[50] Ingolf Schimke,et al. Quality and timeliness in medical laboratory testing , 2009, Analytical and bioanalytical chemistry.
[51] M. Blencowe. Nanoelectromechanical systems , 2005, cond-mat/0502566.
[52] Hadi Shafiee,et al. Emerging Loop-Mediated Isothermal Amplification-Based Microchip and Microdevice Technologies for Nucleic Acid Detection. , 2016, ACS biomaterials science & engineering.
[53] Can Dincer,et al. The impact of biosensing in a pandemic outbreak: COVID-19 , 2020, Biosensors and Bioelectronics.
[54] D. Beebe,et al. The present and future role of microfluidics in biomedical research , 2014, Nature.
[55] O. Wolfbeis,et al. Probes, sensors, and labels: why is real progress slow? , 2013, Angewandte Chemie.
[56] Homayoun Najjaran,et al. Microfluidics Integrated Biosensors: A Leading Technology towards Lab-on-a-Chip and Sensing Applications , 2015, Sensors.
[57] C. Sheridan. Fast, portable tests come online to curb coronavirus pandemic , 2020, Nature Biotechnology.
[58] Ludmila V. Danilova,et al. Detection and localization of surgically resectable cancers with a multi-analyte blood test , 2018, Science.
[59] Victor M Corman,et al. Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR , 2020, Euro surveillance : bulletin Europeen sur les maladies transmissibles = European communicable disease bulletin.
[60] P. Neužil,et al. The vision of point-of-care PCR tests for the COVID-19 pandemic and beyond , 2020, TrAC Trends in Analytical Chemistry.