Noise analysis for near-field intra-body communication systems

This paper describes noise analysis for near-field intra-body communication, in which the human body is the transmission medium. In this type of communication system, the transmission line's impedance balance between the signal and the ground line is extremely degraded. Such a system is affected by large common-mode noise from various kinds of electronic equipment. Impedance balance deteriorates as a result of adding parasitic impedance to the transmission line. A change of impedance balance is estimated by measuring capacitance of the transmission line. We verify that an impedance balance between the signal and the ground line is related to noise power in a nearfield intra-body communication system. A method of connecting an additional electrode to a ground one is an effective way of improving impedance balance and reducing noise.

[1]  Gaetano Borriello,et al.  Empirical measurements of intrabody communication performance under varied physical configurations , 2001, UIST '01.

[2]  Kenji Shiba,et al.  Development of wearable intra-body communication devices , 2003 .

[3]  Kai Zhang,et al.  Modeling and characterization of the electrostatic coupling intra-body communication based on Mach-Zehnder electro-optical modulation. , 2012, Optics express.

[4]  Athanasios V. Vasilakos,et al.  Body Area Networks: A Survey , 2010, Mob. Networks Appl..

[5]  Thomas G. Zimmerman,et al.  : Near-field , 2022 .

[6]  H. Morimura,et al.  Signal-to-Noise Ratio Analysis of a Noisy-Channel Model for a Capacitively Coupled Personal Area Network , 2013, IEEE Transactions on Antennas and Propagation.

[7]  M. Weiser The Computer for the Twenty-First Century , 1991 .

[8]  Koosuke Harada,et al.  Common-Mode Noise Generation in a DC-to-DC Converter , 1980, IEEE Transactions on Aerospace and Electronic Systems.

[9]  Hakaru Kyuragi,et al.  A near-field-sensing transceiver for intrabody communication based on the electrooptic effect , 2004, IEEE Transactions on Instrumentation and Measurement.

[10]  Mitsuru Shinagawa,et al.  AC Electric Field Communication for Human-Area Networking , 2010, IEICE Trans. Electron..

[11]  K. Fujii,et al.  Electric Field Distributions of Wearable Devices Using the Human Body as a Transmission Channel , 2007, IEEE Transactions on Antennas and Propagation.

[12]  Mark Weiser The computer for the 21st century , 1991 .

[13]  Jun Rekimoto,et al.  Wearable key: device for personalizing nearby environment , 2000, Digest of Papers. Fourth International Symposium on Wearable Computers.

[14]  Masao Taki,et al.  Induced Voltage to an Active Implantable Medical Device by a Near-Field Intra-Body Communication Device , 2011, IEICE Trans. Commun..

[15]  Yoshinobu Tonomura,et al.  “Body coupled FingerRing”: wireless wearable keyboard , 1997, CHI.

[16]  Nozomi Haga,et al.  Proper Derivation of Equivalent-Circuit Expressions of Intra-Body Communication Channels Using Quasi-Static Field , 2012, IEICE Trans. Commun..

[17]  Tomoyuki Yambe,et al.  A new transcutaneous bidirectional communication for monitoring implanted artificial heart using the human body as a conductive medium. , 2012, Artificial organs.

[18]  Jianqing Wang,et al.  Analysis of On-Body Transmission Mechanism and Characteristic Based on an Electromagnetic Field Approach , 2009, IEEE Transactions on Microwave Theory and Techniques.

[19]  Hoi-Jun Yoo,et al.  The Human Body Characteristics as a Signal Transmission Medium for Intrabody Communication , 2007, IEEE Transactions on Microwave Theory and Techniques.