A mTurquoise-Based cAMP Sensor for Both FLIM and Ratiometric Read-Out Has Improved Dynamic Range

FRET-based sensors for cyclic Adenosine Mono Phosphate (cAMP) have revolutionized the way in which this important intracellular messenger is studied. The currently prevailing sensors consist of the cAMP-binding protein Epac1, sandwiched between suitable donor- and acceptor fluorescent proteins (FPs). Through a conformational change in Epac1, alterations in cellular cAMP levels lead to a change in FRET that is most commonly detected by either Fluorescence Lifetime Imaging (FLIM) or by Sensitized Emission (SE), e.g., by simple ratio-imaging. We recently reported a range of different Epac-based cAMP sensors with high dynamic range and signal-to-noise ratio. We showed that constructs with cyan FP as donor are optimal for readout by SE, whereas other constructs with green FP donors appeared much more suited for FLIM detection. In this study, we present a new cAMP sensor, termed TEpacVV, which employs mTurquoise as donor. Spectrally very similar to CFP, mTurquoise has about doubled quantum efficiency and unlike CFP, its fluorescence decay is strictly single-exponential. We show that TEpacVV appears optimal for detection both by FLIM and SE, that it has outstanding FRET span and signal-to-noise ratio, and improved photostability. Hence, TEpacVV should become the cAMP sensor of choice for new experiments, both for FLIM and ratiometric detection.

[1]  A. Wittinghofer,et al.  Epac is a Rap1 guanine-nucleotide-exchange factor directly activated by cyclic AMP , 1998, Nature.

[2]  T. Jovin,et al.  FRET imaging , 2003, Nature Biotechnology.

[3]  A. Miyawaki,et al.  Expanded dynamic range of fluorescent indicators for Ca(2+) by circularly permuted yellow fluorescent proteins. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[4]  Martin J. Lohse,et al.  Novel Single Chain cAMP Sensors for Receptor-induced Signal Propagation*♦ , 2004, Journal of Biological Chemistry.

[5]  Kees Jalink,et al.  Detecting cAMP‐induced Epac activation by fluorescence resonance energy transfer: Epac as a novel cAMP indicator , 2004, EMBO reports.

[6]  Xiaodong Cheng,et al.  Fluorescent indicators of cAMP and Epac activation reveal differential dynamics of cAMP signaling within discrete subcellular compartments. , 2004, Proceedings of the National Academy of Sciences of the United States of America.

[7]  E. V. van Munster,et al.  Fluorescence lifetime imaging microscopy (FLIM). , 2005, Advances in biochemical engineering/biotechnology.

[8]  M. Rasenick,et al.  β-Adrenergic Receptor Stimulation Promotes Gαs Internalization through Lipid Rafts: A Study in Living Cells , 2005, Molecular Pharmacology.

[9]  M. Rasenick,et al.  Beta-adrenergic receptor stimulation promotes G alpha s internalization through lipid rafts: a study in living cells. , 2005, Molecular pharmacology.

[10]  Joachim Goedhart,et al.  UvA-DARE ( Digital Academic Repository ) Optimization of fluorescent proteins for novel quantitative multiparameter microscopy approaches , 2007 .

[11]  Pascal Pernot,et al.  Complex fluorescence of the cyan fluorescent protein: comparisons with the H148D variant and consequences for quantitative cell imaging. , 2008, Biochemistry.

[12]  J. Ogink,et al.  A Comparison of Donor-Acceptor Pairs for Genetically Encoded FRET Sensors: Application to the Epac cAMP Sensor as an Example , 2008, PloS one.

[13]  D. Shcherbo,et al.  UvA-DARE ( Digital Academic Repository ) Practical and reliable FRET / FLIM pair of fluorescent proteins , 2009 .

[14]  J. Goedhart,et al.  Bright cyan fluorescent protein variants identified by fluorescence lifetime screening , 2010, Nature Methods.