The air elimination capabilities of pressure infusion devices and fluid‐warmers

Pressurised infusion devices may have only limited capability to detect and remove air during pressurised infusions. In order to assess pressure infusion systems with regard to their actual air elimination capabilities four disposable pressure infusion systems and fluid warmers were investigated: The Level 1® (L‐1), Ranger ® (RA), Gymar® (GY), and the Warmflo® (WF). Different volumes of air were injected proximal to the heat exchanger and the remaining amount of air that was delivered at the end of the tubing was measured during pressurised infusions. Elimination of the injected air (100–200 ml) was superior by the RA system when compared to L‐1 (p < 0.01). The GY and WF systems failed to eliminate the injected air. In conclusion, air elimination was best performed by the RA system. In terms of the risk of air embolism during pressurised infusions, improvements in air elimination of the investigated devices are still necessary.

[1]  M. Comunale A Laboratory Evaluation of the Level 1 Rapid Infuser (H1025) and the Belmont Instrument Fluid Management System (FMS 2000) for Rapid Transfusion , 2003, Anesthesia and analgesia.

[2]  A. Dhillon,et al.  Relative Performance of the Level 1 and Ranger Pressure Infusion Devices , 2003, Anesthesia and analgesia.

[3]  G M Hutchins,et al.  Volume of air in a lethal venous air embolism. , 2001, Anesthesiology.

[4]  D. Buggy Can anaesthetic management influence surgical-wound healing? , 2000, The Lancet.

[5]  T. Toung,et al.  Venous air embolism: a review. , 1997, Journal of clinical anesthesia.

[6]  N. Gravenstein,et al.  Very limited air elimination capability of the level 1 fluid warmer. , 1997, Journal of clinical anesthesia.

[7]  L. Fleisher,et al.  Perioperative maintenance of normothermia reduces the incidence of morbid cardiac events. A randomized clinical trial. , 1997, JAMA.

[8]  H. Kaplan,et al.  Fatal Air Embolism Due to Perioperative Blood Recovery , 1997, Anesthesia and analgesia.

[9]  B. Mainzer,et al.  The use of countercurrent heat exchangers diminishes accidental hypothermia during abdominal aortic aneurysm surgery , 1996, Acta anaesthesiologica Scandinavica.

[10]  A. Kurz,et al.  Perioperative normothermia to reduce the incidence of surgical-wound infection and shorten hospitalization. Study of Wound Infection and Temperature Group. , 1996, The New England journal of medicine.

[11]  D. Sessler,et al.  Mild hypothermia increases blood loss and transfusion requirements during total hip arthroplasty , 1996, The Lancet.

[12]  S. Orebaugh Venous air embolism: Clinical and experimental considerations , 1992, Critical care medicine.

[13]  A. E. Yeakel Lethal air embolism from plastic blood-storage container. , 1968, JAMA.

[14]  P. Lynch,et al.  BODY POSITION IN RELATION TO VENOUS AIR EMBOLISM AND THE ASSOCIATED CARDIOVASCULAR‐RESPIRATORY CHANGES , 1953, The American journal of the medical sciences.

[15]  H. S. Martland Air embolism: Fatal air embolism due to powder insufflators used in gynecological treatments , 1945 .