Automatic Localization of Target Vertebrae in Spine Surgery: Clinical Evaluation of the LevelCheck Registration Algorithm

Study Design. A 3-dimensional-2-dimensional (3D-2D) image registration algorithm, “LevelCheck,” was used to automatically label vertebrae in intraoperative mobile radiographs obtained during spine surgery. Accuracy, computation time, and potential failure modes were evaluated in a retrospective study of 20 patients. Objective. To measure the performance of the LevelCheck algorithm using clinical images acquired during spine surgery. Summary of Background Data. In spine surgery, the potential for wrong level surgery is significant due to the difficulty of localizing target vertebrae based solely on visual impression, palpation, and fluoroscopy. To remedy this difficulty and reduce the risk of wrong-level surgery, our team introduced a program (dubbed LevelCheck) to automatically localize target vertebrae in mobile radiographs using robust 3D-2D image registration to preoperative computed tomographic (CT) scan. Methods. Twenty consecutive patients undergoing thoracolumbar spine surgery, for whom both a preoperative CT scan and an intraoperative mobile radiograph were available, were retrospectively analyzed. A board-certified neuroradiologist determined the “true” vertebra levels in each radiograph. Registration of the preoperative CT scan to the intraoperative radiograph was calculated via LevelCheck, and projection distance errors were analyzed. Five hundred random initializations were performed for each patient, and algorithm settings (viz, the number of robust multistarts, ranging 50–200) were varied to evaluate the trade-off between registration error and computation time. Failure mode analysis was performed by individually analyzing unsuccessful registrations (>5 mm distance error) observed with 50 multistarts. Results. At 200 robust multistarts (computation time of ∼26 s), the registration accuracy was 100% across all 10,000 trials. As the number of multistarts (and computation time) decreased, the registration remained fairly robust, down to 99.3% registration accuracy at 50 multistarts (computation time ∼7 s). Conclusion. The LevelCheck algorithm correctly identified target vertebrae in intraoperative mobile radiographs of the thoracolumbar spine, demonstrating acceptable computation time, compatibility with routinely obtained preoperative CT scans, and warranting investigation in prospective studies. Level of Evidence: N/A

[1]  S. Schafer,et al.  Automatic localization of vertebral levels in x-ray fluoroscopy using 3D-2D registration: a tool to reduce wrong-site surgery , 2012, Physics in medicine and biology.

[2]  Yoshito Otake,et al.  Robust 3D–2D image registration: application to spine interventions and vertebral labeling in the presence of anatomical deformation , 2013, Physics in medicine and biology.

[3]  Jürgen Weese,et al.  A comparison of similarity measures for use in 2-D-3-D medical image registration , 1998, IEEE Transactions on Medical Imaging.

[4]  John Hsiang,et al.  Wrong-level surgery: A unique problem in spine surgery , 2011, Surgical neurology international.

[5]  Bostjan Likar,et al.  A review of 3D/2D registration methods for image-guided interventions , 2012, Medical Image Anal..

[6]  P. Mummaneni,et al.  Avoidance of wrong-level thoracic spine surgery: intraoperative localization with preoperative percutaneous fiducial screw placement. , 2012, Journal of neurosurgery. Spine.

[7]  M. Makary,et al.  Surgical never events in the United States. , 2013, Surgery.

[8]  Marie Diener-West,et al.  Surgical Never Events in the United States , 2013 .

[9]  Caroline Petitjean,et al.  A review of 3 D / 2 D registration methods for image-guided interventions , 2016 .

[10]  Mohammad Alfawareh,et al.  The Prevalence of Wrong Level Surgery Among Spine Surgeons , 2008, Spine.

[11]  Jean-Paul Wolinsky,et al.  Intraoperative Localization of Thoracic Spine Level With Preoperative Percutaneous Placement of Intravertebral Polymethylmethacrylate , 2008, Journal of spinal disorders & techniques.