Characterization of lens based photoacoustic imaging system☆

Some of the challenges in translating photoacoustic (PA) imaging to clinical applications includes limited view of the target tissue, low signal to noise ratio and the high cost of developing real-time systems. Acoustic lens based PA imaging systems, also known as PA cameras are a potential alternative to conventional imaging systems in these scenarios. The 3D focusing action of lens enables real-time C-scan imaging with a 2D transducer array. In this paper, we model the underlying physics in a PA camera in the mathematical framework of an imaging system and derive a closed form expression for the point spread function (PSF). Experimental verification follows including the details on how to design and fabricate the lens inexpensively. The system PSF is evaluated over a 3D volume that can be imaged by this PA camera. Its utility is demonstrated by imaging phantom and an ex vivo human prostate tissue sample.

[1]  J. Litniewski,et al.  Tissue Attenuation Estimation by Mean Frequency Downshift and Bandwidth Limitation , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[2]  F. D. de Mul,et al.  A new theoretical approach to photoacoustic signal generation , 1999 .

[3]  Markus Haltmeier,et al.  Experimental evaluation of reconstruction algorithms for limited view photoacoustic tomography with line detectors , 2007 .

[4]  Zhilie Tang,et al.  Photoacoustic tomography imaging based on a 4f acoustic lens imaging system. , 2007, Optics express.

[5]  I. Calasso,et al.  Photoacoustic point source. , 2001, Physical review letters.

[6]  Lihong V. Wang,et al.  Photoacoustic Tomography: In Vivo Imaging from Organelles to Organs , 2012, Science.

[7]  Jean V. Joseph,et al.  Multispectral Photoacoustic Imaging of Prostate Cancer: Preliminary Ex-vivo Results , 2013, Journal of clinical imaging science.

[8]  Zhilie Tang,et al.  A novel photoacoustic tomography based on a time-resolved technique and an acoustic lens imaging system. , 2006, Physics in medicine and biology.

[9]  Navalgund Rao,et al.  Basics and Clinical Applications of Photoacoustic Imaging , 2009 .

[10]  Keerthi S Valluru,et al.  Photoacoustic Imaging: Opening New Frontiers in Medical Imaging , 2011, Journal of clinical imaging science.

[11]  Wiendelt Steenbergen,et al.  The Twente Photoacoustic Mammoscope: system overview and performance , 2005, Physics in medicine and biology.

[12]  Yongbo Wu,et al.  A simultaneous multiple-section photoacoustic imaging technique based on acoustic lens , 2010 .

[13]  The imaging property of photoacoustic Fourier imaging and tomography using an acoustic lens imaging system , 2007 .

[14]  Lihong V Wang,et al.  Universal back-projection algorithm for photoacoustic computed tomography , 2005, SPIE BiOS.

[15]  T. Anada,et al.  Sound fields focused by a biconcave acoustic lens for normal and oblique incidence , 2005, Europe Oceans 2005.

[16]  T. Tarnoczy,et al.  Sound focussing lenses and waveguides , 1965 .

[17]  Chulhong Kim,et al.  Programmable Real-time Clinical Photoacoustic and Ultrasound Imaging System , 2016, Scientific Reports.

[18]  G. Farhat,et al.  Diagnostic ultrasound Imaging : Inside out , 2004 .

[19]  Bhargava Chinni,et al.  Multi-acoustic lens design methodology for a low cost C-scan photoacoustic imaging camera , 2016, SPIE BiOS.

[20]  P. Beard Biomedical photoacoustic imaging , 2011, Interface Focus.

[21]  Stephen C. Arnold,et al.  Acoustic lens characterization for ultrasound and photoacoustic C-scan imaging modalities , 2008, 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[22]  J. Moalem,et al.  Preliminary results of ex vivo multispectral photoacoustic imaging in the management of thyroid cancer. , 2014, AJR. American journal of roentgenology.

[23]  Lihong V. Wang,et al.  Reconstructions in limited-view thermoacoustic tomography. , 2004, Medical physics.

[24]  J. Goodman Introduction to Fourier optics , 1969 .

[25]  Minghua Xu,et al.  Analytic explanation of spatial resolution related to bandwidth and detector aperture size in thermoacoustic or photoacoustic reconstruction. , 2003, Physical review. E, Statistical, nonlinear, and soft matter physics.

[26]  Navalgund Rao,et al.  Development of a c-scan photoacoutsic imaging probe for prostate cancer detection , 2011, Medical Imaging.

[27]  Daniel Razansky,et al.  Optoacoustic Imaging and Tomography: Reconstruction Approaches and Outstanding Challenges in Image Performance and Quantification , 2013, Sensors.

[28]  Junjie Yao,et al.  Multi-scale photoacoustic tomography using reversibly switchable bacterial phytochrome as a near-infrared photochromic probe , 2015, Nature Methods.

[29]  W. Southwell Using apodization functions to reduce sidelobes in rugate filters. , 1989, Applied optics.

[30]  K. Valluru,et al.  Probe design for Photoacoustic imaging of prostate , 2010, 2010 IEEE International Conference on Imaging Systems and Techniques.

[31]  Zhilie Tang,et al.  Photoacoustic tomography imaging using a 4f acoustic lens and peak-hold technology. , 2008, Optics express.