Influence of the winding design of wind turbine transformers for resonant overvoltage vulnerability

Switching transients and earth faults may lead to resonant overvoltages at wind turbine transformer terminals as well as inside High Voltage (HV) and Low Voltage (LV) windings. The winding design in a transformer could strongly influence the internal voltage distribution as function of frequency, and this has a great impact on risk of insulation failure. In this paper, resonant overvoltages in three winding designs; layer, disc and pancake, are investigated and analyzed for the application in offshore wind farm. To achieve this, a prototype 500 kVA transformer with the three winding types on the HV side and taps for voltage measurements is designed and produced. The measurements show that a HV winding of layer type gives the highest transferred voltage to the LV terminal and that this happens at 1.6 MHz which could be excited for close-up earth faults. Although disc winding seems the least vulnerable when measuring the transferred voltage to the LV terminal, it has higher potential of internal resonances in the HV winding compared to the two other types both voltage-to-ground and voltage drops. Pancake and layer windings have less vulnerability in the case of internal resonances. Pancake windings have modular design characteristic. This advantage eases the repair for offshore wind applications.

[1]  Eilert Bjerkan High frequency modeling of power transformers: Stresses and Diagnostics , 2005 .

[2]  A. H. Soloota,et al.  Modeling of wind turbine transformers for the analysis of resonant overvoltages , 2016 .

[3]  G. Borner,et al.  Failure mechanism of the interturn insulation of low voltage electric machines fed by pulse-controll , 1996 .

[4]  R. C. Degeneff,et al.  Transformer Response to System Switching Voltages , 1982, IEEE Transactions on Power Apparatus and Systems.

[5]  G. C. Paap,et al.  Computation of Very Fast Transient Overvoltages in Transformer Windings , 2002, IEEE Power Engineering Review.

[6]  T. J. Blalock,et al.  Response of Transformer Windings to System Transient Voltages , 1974 .

[7]  Inoue Tamotsu,et al.  V-t characteristics and Probabilistic Distribution of Partial Discharge and Breakdown Voltages for Transformer Insulation , 1981 .

[8]  Bjørn Gustavsen,et al.  Multivariate Analysis of Transformer Resonant Overvoltages in Power Stations , 2011, IEEE Transactions on Power Delivery.

[9]  B. Gustavsen,et al.  A STUDY OF SWITCHING OVERVOLTAGES IN OFFSHORE WIND FARM , 2011 .

[10]  M. Nishioka,et al.  Internal winding failure due to resonance overvoltage in distribution transformer caused by winter lightning , 2006, 2006 IEEE Power Engineering Society General Meeting.

[11]  M. Kaufhold,et al.  Failure mechanism of the interturn insulation of low voltage electric machines fed by pulse controlled inverters , 1995, Proceedings of 1995 Conference on Electrical Insulation and Dielectric Phenomena.

[12]  M. Nishioka,et al.  Internal winding failure due to resonance overvoltage in distribution transformer caused by winter lightning , 2006, IEEE Transactions on Power Delivery.

[13]  A. S. Morched,et al.  Analysis of internal winding stresses in EHV generator step-up transformer failures , 1996 .

[14]  Bruce A. Mork,et al.  Investigation of Resonant Overvoltages in Offshore Wind Farms-Modeling and Protection , 2013 .

[15]  S. A. Ryder,et al.  Diagnosing transformer faults using frequency response analysis , 2003 .

[16]  Bjorn Gustavsen,et al.  Frequency domain investigation of switching transients in Offshore Wind Farms , 2011, 2011 IEEE Trondheim PowerTech.

[17]  B. Gustavsen,et al.  The effect of winding design on transformer frequency response with application on offshore wind farm energization , 2012, 2012 International Conference on Renewable Energy Research and Applications (ICRERA).

[18]  Tarik Abdulahovic Analysis of High-Frequency Electrical Transients in Offshore Wind Parks , 2011 .

[19]  Y. Shibuya,et al.  Analysis of very fast transient overvoltage in transformer winding , 1997 .

[20]  D. Van Dommelen,et al.  Experimental and numerical analysis of fast transient phenomena in distribution transformers , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[21]  T Adielson,et al.  Resonant Overvoltages in EHV Transformers-Modeling and Application , 1981, IEEE Transactions on Power Apparatus and Systems.

[22]  Bjorn Gustavsen,et al.  Internal resonant overvoltage in wind turbine transformers- sensitivity analysis of measurement techniques , 2013, 2013 International Conference on Electrical Machines and Systems (ICEMS).

[23]  Abb Corporate Transfer Function Based Recognition of Resonance Overvoltages in Transformer Windings , 2008 .

[24]  Hiroshi Kurita,et al.  High‐frequency voltage oscillation in transformer windings and electrical breakdown properties of interturn insulation immersed in oil at VFT voltage , 2000 .

[25]  Inoue Tamotsu,et al.  Dielectric strength of transformer insulation against oscillatory impulse voltages , 1984 .