Development and initial evaluation of a finite element model of the pediatric craniocervical junction.

OBJECT There is a significant deficiency in understanding the biomechanics of the pediatric craniocervical junction (CCJ) (occiput-C2), primarily because of a lack of human pediatric cadaveric tissue and the relatively small number of treated patients. To overcome this deficiency, a finite element model (FEM) of the pediatric CCJ was created using pediatric geometry and parameterized adult material properties. The model was evaluated under the physiological range of motion (ROM) for flexion-extension, axial rotation, and lateral bending and under tensile loading. METHODS This research utilizes the FEM method, which is a numerical solution technique for discretizing and analyzing systems. The FEM method has been widely used in the field of biomechanics. A CT scan of a 13-month-old female patient was used to create the 3D geometry and surfaces of the FEM model, and an open-source FEM software suite was used to apply the material properties and boundary and loading conditions and analyze the model. The published adult ligament properties were reduced to 50%, 25%, and 10% of the original stiffness in various iterations of the model, and the resulting ROMs for flexion-extension, axial rotation, and lateral bending were compared. The flexion-extension ROMs and tensile stiffness that were predicted by the model were evaluated using previously published experimental measurements from pediatric cadaveric tissues. RESULTS The model predicted a ROM within 1 standard deviation of the published pediatric ROM data for flexion-extension at 10% of adult ligament stiffness. The model's response in terms of axial tension also coincided well with published experimental tension characterization data. The model behaved relatively stiffer in extension than in flexion. The axial rotation and lateral bending results showed symmetric ROM, but there are currently no published pediatric experimental data available for comparison. The model predicts a relatively stiffer ROM in both axial rotation and lateral bending in comparison with flexion-extension. As expected, the flexion-extension, axial rotation, and lateral bending ROMs increased with the decrease in ligament stiffness. CONCLUSIONS An FEM of the pediatric CCJ was created that accurately predicts flexion-extension ROM and axial force displacement of occiput-C2 when the ligament material properties are reduced to 10% of the published adult ligament properties. This model gives a reasonable prediction of pediatric cervical spine ligament stiffness, the relationship between flexion-extension ROM, and ligament stiffness at the CCJ. The creation of this model using open-source software means that other researchers will be able to use the model as a starting point for research.

[1]  N Yoganandan,et al.  Biomechanical study of pediatric human cervical spine: a finite element approach. , 2000, Journal of biomechanical engineering.

[2]  E Schneider,et al.  Biomechanics of the craniocervical region: The alar and transverse ligaments , 1988, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[3]  Jiri Dvorak,et al.  The mechanical properties of human alar and transverse ligaments at slow and fast extension rates. , 1998, Clinical biomechanics.

[4]  Roger W. Nightingale,et al.  Tensile Failure Properties of the Perinatal, Neonatal, and Pediatric Cadaveric Cervical Spine , 2013, Spine.

[5]  K. Brolin,et al.  Development of a Finite Element Model of the Upper Cervical Spine and a Parameter Study of Ligament Characteristics , 2004, Spine.

[6]  Qingan Zhu,et al.  Biomechanical Assessment of the Pediatric Cervical Spine Under Bending and Tensile Loading , 2005, Spine.

[7]  P. D. Leahy,et al.  The effects of ligamentous injury in the human lower cervical spine. , 2012, Journal of biomechanics.

[8]  Shawn P. Reese,et al.  Micromechanical model of a surrogate for collagenous soft tissues: development, validation and analysis of mesoscale size effects , 2013, Biomechanics and modeling in mechanobiology.

[9]  Hao Zhang,et al.  Development and Validation of a Finite Element Model of the Occipito-Atlantoaxial Complex Under Physiologic Loads , 2007, Spine.

[10]  V C Mow,et al.  Finite deformation biphasic material properties of bovine articular cartilage from confined compression experiments. , 1997, Journal of biomechanics.

[11]  J. Luck,et al.  The Biomechanics of the Perinatal, Neonatal and Pediatric Cervical Spine: Investigation of the Tensile, Bending and Viscoelastic Response , 2012 .

[12]  Jac Wismans,et al.  Child restraint evaluation by experimental and mathematical simulation , 1979 .

[13]  Dachling Pang,et al.  Atlantoaxial Rotatory Fixation: Part 1—Biomechanics OF Normal Rotation at the Atlantoaxial Joint in Children , 2004, Neurosurgery.

[14]  N Yoganandan,et al.  Biomechanics of the cervical spine Part 2. Cervical spine soft tissue responses and biomechanical modeling. , 2001, Clinical biomechanics.

[15]  A Rohlmann,et al.  Comparison of eight published static finite element models of the intact lumbar spine: predictive power of models improves when combined together. , 2014, Journal of biomechanics.

[16]  Benjamin J. Ellis,et al.  FEBio: finite elements for biomechanics. , 2012, Journal of biomechanical engineering.

[17]  W. Nemzek,et al.  ATLANTO‐OCCIPITAL DISLOCATION: PART 1—NORMAL OCCIPITAL CONDYLE‐C1 INTERVAL IN 89 CHILDREN , 2007, Neurosurgery.

[18]  Benjamin J. Ellis,et al.  Specimen-specific predictions of contact stress under physiological loading in the human hip: validation and sensitivity studies , 2013, Biomechanics and Modeling in Mechanobiology.

[19]  R. Hurlbert,et al.  A biomechanical evaluation of occipitocervical instrumentation: screw compared with wire fixation. , 1999, Journal of neurosurgery.

[20]  Benjamin J Ellis,et al.  Medial collateral ligament insertion site and contact forces in the ACL‐deficient knee , 2006, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[21]  V K Goel,et al.  A Finite Element Investigation of Upper Cervical Instrumentation , 2001, Spine.

[22]  J Dvorak,et al.  CT‐Functional Diagnostics of the Rotatory Instability of Upper Cervical Spine: 1. An Experimental Study on Cadavers , 1987, Spine.

[23]  J. Weiss,et al.  The impact of glenoid labrum thickness and modulus on labrum and glenohumeral capsule function. , 2010, Journal of biomechanical engineering.

[24]  Patrick J McMahon,et al.  Methodology and sensitivity studies for finite element modeling of the inferior glenohumeral ligament complex. , 2007, Journal of biomechanics.

[25]  V. Goel,et al.  Biomechanical rationale for the pathology of rheumatoid arthritis in the craniovertebral junction. , 2000, Spine.

[26]  Dimitrios Kallieris,et al.  COMPARISON BETWEEN CHILD CADAVERS AND CHILD DUMMY BY USING CHILD RESTRAINT SYSTEMS IN SIMULATED COLLISIONS , 1976 .

[27]  King H. Yang,et al.  Development and Validation of a 10-Year-Old Child Ligamentous Cervical Spine Finite Element Model , 2013, Annals of Biomedical Engineering.

[28]  Gerard A Ateshian,et al.  Equivalence between short-time biphasic and incompressible elastic material responses. , 2007, Journal of biomechanical engineering.

[29]  Alan T Dibb,et al.  Tensile mechanical properties of the perinatal and pediatric PMHS osteoligamentous cervical spine. , 2008, Stapp car crash journal.

[30]  Patrick J McMahon,et al.  Finite element modelling of the glenohumeral capsule can help assess the tested region during a clinical exam , 2010, Computer methods in biomechanics and biomedical engineering.

[31]  Christian M. Puttlitz,et al.  Finite Element Modeling of Kinematic and Load Transmission Alterations due to Cervical Intervertebral Disc Replacement , 2011, Spine.

[32]  John J Callaghan,et al.  The capsule's contribution to total hip construct stability – A finite element analysis , 2011, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[33]  O. C. Zienkiewicz,et al.  Basic formulation and linear problems , 1989 .

[34]  Patrick Devin Leahy Assessment of the effects of ligamentous injury in the human cervical spine , 2012 .

[35]  Benjamin J. Ellis,et al.  Muscle connective tissue controls development of the diaphragm and is a source of congenital diaphragmatic hernias , 2015, Nature Genetics.

[36]  Jong-Ki Kim,et al.  In Vivo Proton Magnetic Resonance Spectroscopy of Human Spinal Mass Lesions , 2004, Journal of spinal disorders & techniques.

[37]  Benjamin J. Ellis,et al.  Patient-specific analysis of cartilage and labrum mechanics in human hips with acetabular dysplasia. , 2014, Osteoarthritis and cartilage.

[38]  Christian M. Puttlitz,et al.  Parametric convergence sensitivity and validation of a finite element model of the human lumbar spine , 2011, Computer methods in biomechanics and biomedical engineering.

[39]  Benjamin J. Ellis,et al.  Validation of finite element predictions of cartilage contact pressure in the human hip joint. , 2008, Journal of biomechanical engineering.