Bioethanol in Biofuels Checked by an Amperometric Organic Phase Enzyme Electrode (OPEE) Working in “Substrate Antagonism” Format

The bioethanol content of two samples of biofuels was determined directly, after simple dilution in decane, by means of an amperometric catalase enzyme biosensor working in the organic phase, based on substrate antagonisms format. The results were good from the point of view of accuracy, and satisfactory for what concerns the recovery test by the standard addition method. Limit of detection (LOD) was on the order of 2.5 × 10−5 M.

[1]  P. Coulet What is a biosensor? , 2019, Bioprocess technology.

[2]  G. Favero,et al.  Two OPEEs (organic phase enzyme electrodes) used to check the percentage water content in hydrophobic foods and drugs. , 2001, The Analyst.

[3]  B. Danielsson,et al.  Enzyme thermistor devices. , 1976, Methods in enzymology.

[4]  Kim R. Rogers,et al.  Biosensors for environmental applications , 1995 .

[5]  J H Luong,et al.  Analytical applications of piezoelectric crystal biosensors. , 1991, Bioprocess technology.

[6]  L. Campanella,et al.  An innovative organic phase enzyme electrode (OPEE) for the determination of ethanol in leadless petrols , 2010 .

[7]  Jean-Michel Kauffmann,et al.  Biosensors in Drug Discovery and Drug Analysis , 2005 .

[8]  L. Campanella,et al.  New Immunosensors Operating in Organic Phase (OPIEs) for Analysis of Triazinic Pesticides in Olive Oil , 2012 .

[9]  A. Klibanov,et al.  Are water-immiscibility and apolarity of the solvent relevant to enzyme efficiency? , 1993, Biotechnology and bioengineering.

[10]  L. Campanella,et al.  Determination of hydroperoxides in nonaqueous solvents or mixed solvents, using a biosensor with two antagonist enzymes operating in parallel , 2003 .

[11]  Shaojun Dong,et al.  Amperometric biosensor for tyrosinase inhibitors in a pure organic phase , 1996 .

[12]  I. Popescu,et al.  Phenols monitoring and Hill coefficient evaluation using tyrosinase-based amperometric biosensors. , 2004, Bioelectrochemistry.

[13]  M. Smyth,et al.  Organic phase enzyme electrodes: kinetics and analytical applications , 1997 .

[14]  Charles E. Wyman,et al.  Ethanol from lignocellulosic biomass: Technology, economics, and opportunities , 1994 .

[15]  M. Smyth,et al.  Solvent effects on the reactivities of an amperometric glucose sensor , 1995 .

[16]  L. Campanella,et al.  Tyrosinase biosensor response as a function of physical properties of organic solvents. , 1994, Talanta.

[17]  G. Favero,et al.  The effect of organic solvent properties on the response of a tyrosinase enzyme sensor. , 1994, Talanta.

[18]  Etienne Poitrat,et al.  The potential of liquid biofuels in France , 1999 .

[19]  J. Moreira,et al.  The alcohol program , 1999 .

[20]  M. Smyth,et al.  Kinetic characterization of the effects of organic solvents on the performance of a peroxidase‐modified electrode in detecting peroxides, thiourea and ethylenethiourea , 1995 .

[21]  D. Wise Bioinstrumentation: Research, Developments and Applications , 1990 .

[22]  Luca Konig,et al.  Enzymatic Methods Of Analysis , 2016 .

[23]  G. Favero,et al.  Enzymatic immobilisation in kappa-carrageenan gel suitable for organic phase enzyme electrode (OPEE) assembly , 1999 .

[24]  M. S. López,et al.  Organic phase enzyme electrodes. , 2006, Biomolecular engineering.

[25]  Luigi Campanella,et al.  Determination of traces of several pesticides in sunflower oil using organic phase immuno electrodes (OPIEs). , 2015, Talanta.

[26]  A. Wheals,et al.  Fuel ethanol after 25 years. , 1999, Trends in biotechnology.

[27]  Jonathan S. Dordick,et al.  Enzymatic catalysis in monophasic organic solvents , 1989 .

[28]  L. Campanella,et al.  The effect of organic solvent properties on a catalase enzyme sensor for monitoring hydrogen peroxide in nonaqueous solutions , 1996 .

[29]  M. Smyth,et al.  Kinetic Study of the Inhibitory Effects of Methyl Isothiocyanate on a Peroxidase-Modified Platinum Electrode in Non-Aqueous Media , 1994 .

[30]  M. Smyth,et al.  Determination of kinetic parameters for the inhibitory effects of organic sulphides on an amperometric peroxide biosensor in non-aqueous media. , 1994, Talanta.

[31]  L. Campanella,et al.  Agent orange herbicides, organophosphate and triazinic pesticides analysis in olive oil and industrial oil mill waste effluents using new organic phase immunosensors. , 2015, Food chemistry.

[32]  L. Campanella,et al.  A new catalase enzyme sensor able to determine the hydrogen peroxide directly in chloroform , 1996 .

[33]  Bengt Danielsson Analytical uses of immobilized enzymes , 1985 .

[34]  A. Iob,et al.  Determination of oxygenates in gasoline by FTIR , 1998 .