Application of the noise power spectrum in modern diagnostic MDCT: part I. Measurement of noise power spectra and noise equivalent quanta

Dose reduction efforts in diagnostic CT have brought the tradeoff of dose versus image quality to the forefront. The need for meaningful characterization of image noise beyond that offered by pixel standard deviation is becoming increasingly important. This work aims to study the implementation of the noise power spectrum (NPS) and noise equivalent quanta (NEQ) on modern, multislice diagnostic CT scanners. The details of NPS and NEQ measurement are outlined and special attention is paid to issues unique to multislice CT. Aliasing, filter design and effects of acquisition geometry are investigated. While it was found that both metrics can be implemented in modern CT, it was discovered that NEQ cannot be aptly applied with certain non-traditional reconstruction filters or in helical mode. NPS and NEQ under a variety of conditions are examined. Extensions of NPS and NEQ to uses in protocol standardization are also discussed.

[1]  E. Pisano,et al.  Imaging and cancer: research strategy of the American College of Radiology Imaging Network. , 2005, Radiology.

[2]  D. Jaffray,et al.  A framework for noise-power spectrum analysis of multidimensional images. , 2002, Medical physics.

[3]  W A Kalender,et al.  Advanced single-slice rebinning for tilted spiral cone-beam CT. , 2001, Medical physics.

[4]  M F Kijewski,et al.  The noise power spectrum of CT images. , 1987, Physics in medicine and biology.

[5]  J. Ehrhardt,et al.  Modulation transfer function of the EMI CT head scanner. , 1977, Medical physics.

[6]  R. Detrano,et al.  Calcified coronary artery plaque measurement with cardiac CT in population-based studies: standardized protocol of Multi-Ethnic Study of Atherosclerosis (MESA) and Coronary Artery Risk Development in Young Adults (CARDIA) study. , 2005, Radiology.

[7]  Aruna A. Vedula,et al.  A computer simulation study comparing lesion detection accuracy with digital mammography, breast tomosynthesis, and cone-beam CT breast imaging. , 2006, Medical physics.

[8]  Michael McNitt-Gray,et al.  Coronary calcium measurements: effect of CT scanner type and calcium measure on rescan reproducibility--MESA study. , 2005, Radiology.

[9]  Norbert J. Pelc,et al.  The noise power spectrum in computed X-ray tomography. , 1978 .

[10]  D. C. Barber,et al.  Medical Imaging-The Assessment of Image Quality , 1996 .

[11]  K. Hanson,et al.  Detectability in computed tomographic images. , 1979, Medical physics.

[12]  C. Shaw,et al.  Noise simulation in cone beam CT imaging with parallel computing. , 2006, Physics in medicine and biology.

[13]  Jonathan G Goldin,et al.  Emphysema: effect of reconstruction algorithm on CT imaging measures. , 2004, Radiology.

[14]  Shuhei Komatsu,et al.  A combination-weighted Feldkamp-based reconstruction algorithm for cone-beam CT , 2006, Physics in medicine and biology.

[15]  R. F. Wagner,et al.  Application of information theory to the assessment of computed tomography. , 1979, Medical physics.

[16]  K Faulkner,et al.  Analysis of x-ray computed tomography images using the noise power spectrum and autocorrelation function. , 1984, Physics in medicine and biology.