Real-time Detection of Vessel Diameters with Ultrasound. Echtzeiterkennung von Gefäßdurchmessern mit Ultraschall

Transcutaneous vessel imaging is a frequently used ultrasound imaging modality in medicine. The measurement of vessel diameters can be done with conventional B-mode imaging systems, which work at frame rates up to 100 Hz. Furthermore, there are special systems available, which can track vessel walls very precisely using the phase of signals that are sent at frame rates up to several thousand Hz. Though, such systems are usually not able to provide the examiner with 2D images of the object. With respect to brachial artery flow-mediated vasodilatation (FMD), which is frequently used as a measure of endothelial function, it is necessary to observe diameter changes of small arterial vessels noninvasively for several minutes at a high resolution. In the past, the diameter had to be measured manually in tedious postprocessing of ECG-gated image sequences. We developed a system composed of a Siemens Omnia ultrasound system with a VF13-5 transducer (9 MHz center frequency) and a personal computer, that is capable of calculating vessel diameter changes with an accuracy below the wavelength of the ultrasound system in real-time at a frame rate of 27 Hz. We implemented a two-dimensional active contour model using the Viter-bi-algorithm and a phase-sensitive vessel wall tracking algorithm, in order to guarantee both, geometric information and accuracy. Results from carotid and brachial arteries show that arterial pulsations below 0.1 mm can be visualized reliably over several minutes. With this system we want to find out, if FMD is suitable for an individual assessment of the risk for cardiovascular diseases.

[1]  L. Heuser,et al.  Freehand ultrasound elastography of breast lesions: clinical results. , 2001, Ultrasound in medicine & biology.

[2]  D. Hokanson,et al.  A phase-locked echo tracking system for recording arterial diameter changes in vivo. , 1972, Journal of applied physiology.

[3]  D H Groves,et al.  A digital technique for tracking moving interfaces. , 1982, Ultrasound in medicine & biology.

[4]  Jr. G. Forney,et al.  The viterbi algorithm , 1973 .

[5]  M. O’Donnell,et al.  Internal displacement and strain imaging using ultrasonic speckle tracking , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[6]  M. Enderle,et al.  Endothelial Function, Variables of Fibrinolysis and Coagulation in Smokers and Healthy Controls , 2000, Pathophysiology of Haemostasis and Thrombosis.

[7]  T Gustavsson,et al.  Ultrasound measurement of wall thickness in the carotid artery: fundamental principles and description of a computerized analysing system. , 1991, Clinical physiology.

[8]  Demetri Terzopoulos,et al.  Deformable models in medical image analysis: a survey , 1996, Medical Image Anal..

[9]  David M. Herrington,et al.  Ultrasound measurement of brachial flow-mediated vasodilator response , 2000, IEEE Transactions on Medical Imaging.

[10]  H. Ermert,et al.  A time-efficient and accurate strain estimation concept for ultrasonic elastography using iterative phase zero estimation , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  J. K. Lloyd,et al.  Non-invasive detection of endothelial dysfunction in children and adults at risk of atherosclerosis , 1992, The Lancet.