Simultaneous Operation of Personal Computers and Mathematical Assessment of Their Harmonic Impact on the Grid

In the smart grids environment, non-linear electronic devices are present to a great extent. Since these devices generate higher harmonics in the current spectrum and require high voltage quality in order to operate properly, the power quality issue becomes very important. This study deals with mathematical modelling of parameters of current and voltage harmonic distortion due to operation of PC cluster. The proposed models are developed using measurements and simulation results. Model parameters are derived in the least squares manner. The models are convenient for practical engineering application.

[1]  S. Manjunatha,et al.  Assessment of Distributed Generation Source Impact on Electrical Distribution System Performance , 2010 .

[2]  Chi-Jui Wu,et al.  Application of regression models to predict harmonic voltage and current growth trend from measurement data at secondary substations , 1998 .

[3]  Ángel Molina-García,et al.  A measurement approach for obtaining static load model parameters in real time at the distribution level , 2007 .

[4]  D. J. Pileggi,et al.  Voltage distortion in distribution feeders with nonlinear loads - Discussion , 1994 .

[5]  Jing Yong,et al.  A Study on the Harmonic Contributions of Residential Loads , 2011, IEEE Transactions on Power Delivery.

[6]  S. P. Singh,et al.  Harmonics estimation and modeling of residential and commercial loads , 2009, 2009 International Conference on Power Systems.

[7]  Vladimir Katic,et al.  The Impact of the Load Side Parameters on PC Cluster's Harmonics Emission , 2011 .

[8]  Luis Sainz,et al.  Statistical Study of Personal Computer Cluster Harmonic Currents from Experimental Measurements , 2015 .

[9]  F. Blaabjerg,et al.  Harmonic cancellation by mixing nonlinear single-phase and three-phase loads , 1998, Conference Record of 1998 IEEE Industry Applications Conference. Thirty-Third IAS Annual Meeting (Cat. No.98CH36242).

[10]  Mohammad A. S. Masoum,et al.  Power Quality in Power Systems and Electrical Machines , 2008 .

[11]  Colin C Davidson Power transmission with power electronics , 2011, Proceedings of the 2011 14th European Conference on Power Electronics and Applications.

[12]  Vladimir Katic,et al.  Multi-parameter mathematical model for determination of PC cluster total harmonic distortion of input current , 2016 .

[13]  S. Herraiz,et al.  Behaviour of single‐phase full‐wave rectifier , 2003 .

[14]  Muhammad Akmal,et al.  Mathematical Modeling of Current Harmonics Caused by Personal Computers , 2008 .

[15]  V. Katie,et al.  Effects of low power electronics & computer equipment on power quality at distribution grid-measurements and forecast , 2004, 2004 IEEE International Conference on Industrial Technology, 2004. IEEE ICIT '04..

[16]  Vladimir Katic,et al.  Improved analytical expression for calculating total harmonic distortion of PC clusters , 2011 .

[17]  Vladimir Katic,et al.  Least Squares Modeling of Voltage Harmonic Distortion Due to PC Cluster Operation , 2013 .

[18]  L. Sainz,et al.  A unified and simple model for uncontrolled rectifiers , 2005 .

[19]  V. A. Katic,et al.  The Hybrid Method for On-line Harmonic Analysis , 2011 .

[20]  Muhyaddin J. H. Rawa,et al.  Background voltage distortion and percentage of nonlinear load impacts on the harmonics produced by a group of Personal Computers , 2014, 2014 International Symposium on Electromagnetic Compatibility.

[21]  Badr M. Alshammari,et al.  Power system performance quality indices , 2011 .

[22]  W. M. Grady,et al.  An investigation of harmonics attenuation and diversity among distributed single-phase power electronic loads , 1994 .

[23]  Gheorghe Grigoras,et al.  Clustering Techniques in Load Profile Analysis for Distribution Stations , 2009 .