Resolution Enhancement in Surface Plasmon Resonance Sensor Based on Waveguide Coupled Mode by Combining a Bimetallic Approach

In this study, we present and demonstrate a new route to a great enhancement in resolution of surface plasmon resonance sensors. Basically, our approach combines a waveguide coupled plasmonic mode and a kind of Au/Ag bimetallic enhancement concept. Theoretical modeling was carried out by solving Fresnel equations for the multilayer stack of prism/Ag inner-metal layer/dielectric waveguide/Au outer-metal layer. The inner Ag layer couples incident light to a guided wave and makes more fields effectively concentrated on the outer Au surface. A substantial enhancement in resolution was experimentally verified for the model stack using a ZnS-SiO2 waveguide layer.

[1]  H. S. Wolff,et al.  iRun: Horizontal and Vertical Shape of a Region-Based Graph Compression , 2022, Sensors.

[2]  J. Homola Surface plasmon resonance based sensors , 2006 .

[3]  Chih-Kung Lee,et al.  Design and fabrication of an alternating dielectric multi-layer device for surface plasmon resonance sensor , 2006 .

[4]  Jukka Räty,et al.  The complex refractive index measurement of liquids by a novel reflectometer apparatus for the UV - visible spectral range , 1998 .

[5]  Ibrahim Abdulhalim,et al.  Surface Plasmon Resonance for Biosensing: A Mini-Review , 2008 .

[6]  J. Homola,et al.  Surface Plasmon Resonance (SPR) Sensors , 2006 .

[7]  Xiaocong Yuan,et al.  Optimised film thickness for maximum evanescent field enhancement of a bimetallic film surface plasmon resonance biosensor , 2006 .

[8]  Yuri M. Shirshov,et al.  Bimetallic Layers Increase Sensitivity of Affinity Sensors Based on Surface Plasmon Resonance , 2002 .

[9]  Jiri Homola,et al.  Dual-channel surface plasmon resonance sensor with spectral discrimination of sensing channels using dielectric overlayer , 1999 .

[10]  F. Chien,et al.  A sensitivity comparison of optical biosensors based on four different surface plasmon resonance modes. , 2004, Biosensors & bioelectronics.

[11]  Liann-Be Chang,et al.  High-sensitivity sensor based on surface plasmon resonance and heterodyne interferometry , 2003 .

[12]  Christian Grunwald,et al.  Double-wavelength technique for surface plasmon resonance measurements: basic concept and applications for single sensors and two-dimensional sensor arrays. , 2005, Analytical chemistry.

[13]  W. Knoll,et al.  Long Range Surface Plasmons for Observation of Biomolecular Binding Events at Metallic Surfaces , 2007 .

[14]  B. Liedberg,et al.  Gas detection by means of surface plasmon resonance , 1982 .

[15]  R. Corn,et al.  Surface plasmon resonance imaging measurements of ultrathin organic films. , 2003, Annual review of physical chemistry.

[16]  Petr I. Nikitin,et al.  Surface plasmon resonance interferometry for biological and chemical sensing , 1999 .

[17]  Jiří Homola,et al.  Long-range surface plasmons for high-resolution surface plasmon resonance sensors , 2001 .

[18]  E. Kretschmann Die Bestimmung optischer Konstanten von Metallen durch Anregung von Oberflächenplasmaschwingungen , 1971 .

[19]  X. D. Hoa,et al.  Towards integrated and sensitive surface plasmon resonance biosensors: a review of recent progress. , 2007, Biosensors & bioelectronics.