Comparison of two-color methods based on wavelength and adjacent pulse repetition interval length

This paper describes the characteristics of a two-color method based on the adjacent pulse repetition interval length (APRIL), which functions as a length unit for femtosecond optical frequency combs (FOFCs), and compares the results to the wavelength-based two-color method. The wavelength-based two-color method can eliminate the inhomogeneous disturbance of effects caused by the phase refractive index; therefore, the APRIL-based two-color method can eliminate the air turbulence of errors induced by the group refractive index. Our numerical analysis of the APRIL-based two-color method will contribute to the pulse-laser-based two-color method, which secures traceability to the definition of the meter via APRIL.

[1]  James C. Owens,et al.  Correction of optical distance measurements for the fluctuating atmospheric index of refraction , 1965 .

[2]  B. Edĺen The Refractive Index of Air , 1966 .

[3]  K. B. Earnshaw,et al.  Two-Laser Optical Distance-Measuring Instrument that Corrects for the Atmospheric Index of Refraction. , 1972, Applied optics.

[4]  B Querzola,et al.  High accuracy distance measurement by two-wavelength pulsed laser sources. , 1979, Applied optics.

[5]  K. Miyake Optical pulsed ranging: effect of atmospheric scintillation on measurement accuracy , 1981 .

[6]  Estler Wt,et al.  High-accuracy displacement interferometry in air. , 1985 .

[7]  Akira Ishida,et al.  Two-Wavelength Displacement-Measuring Interferometer Using Second-Harmonic Light to Eliminate Air-Turbulence-Induced Errors , 1989 .

[8]  Study of Charge Density Waves in 4Hb–TaS2 by STM/STS , 1989 .

[9]  M. Teich,et al.  Fundamentals of Photonics , 1991 .

[10]  H. Matsumoto,et al.  High-accuracy length-measuring interferometer using the two-colour method of compensating for the refractive index of air , 1992 .

[11]  H. Matsumoto,et al.  Measurement of the changes in air refractive index and distance by means of a two-color interferometer. , 1992, Applied optics.

[12]  K. P. Birch,et al.  An Updated Edln Equation for the Refractive Index of Air , 1993 .

[13]  I. Ogawa,et al.  Streak-camera-based long-distance range finder with 10(-7) resolution. , 1994, Applied optics.

[14]  A. Chekhovsky,et al.  Three-color optical range finding. , 1994, Applied optics.

[15]  Hirokazu Matsumoto,et al.  Length measurement by a two-colour interferometer using two close wavelengths to reduce errors caused by air turbulence , 1999 .

[16]  K. Minoshima,et al.  High-accuracy measurement of 240-m distance in an optical tunnel by use of a compact femtosecond laser. , 2000, Applied optics.

[17]  H. Matsumoto,et al.  Reducing the quantization error and miscount error in two-color interferometers by combining a coefficient compensation technique with a fringe-count averaging technique , 2000 .

[18]  Hirokazu Matsumoto,et al.  Direct measurement of the group refractive index of air with interferometry between adjacent femtosecond pulses. , 2002, Applied optics.

[19]  Akiko Hirai,et al.  A two-color heterodyne interferometer for measuring the refractive index of air using an optical diffraction grating , 2002 .

[20]  Jun Ye Absolute measurement of a long, arbitrary distance to less than an optical fringe. , 2004, Optics letters.

[21]  J. Ye,et al.  Femtosecond Optical Frequency Comb: Principle, Operation and Applications , 2010 .

[22]  K. Meiners-Hagen,et al.  Refractive index determination in length measurement by two-colour interferometry , 2008 .

[23]  J J M Braat,et al.  High-accuracy long-distance measurements in air with a frequency comb laser. , 2009, Optics letters.

[24]  S. A. van den Berg,et al.  Femtosecond frequency comb based distance measurement in air. , 2009, Optics express.

[25]  Young-Jin Kim,et al.  Time-of-flight measurement with femtosecond light pulses , 2010 .

[26]  Dong Wei,et al.  Time-of-flight method using multiple pulse train interference as a time recorder. , 2011, Optics express.

[27]  K. Minoshima,et al.  High-accuracy self-correction of refractive index of air using two-color interferometry of optical frequency combs. , 2011, Optics express.

[28]  Kaoru Minoshima,et al.  Extremely high-accuracy correction of air refractive index using two-colour optical frequency combs , 2013, Scientific Reports.

[29]  Kaoru Minoshima,et al.  Pulse-to-pulse alignment technique based on synthetic-wavelength interferometry of optical frequency combs for distance measurement. , 2013, Optics letters.

[30]  Dong Wei,et al.  Characteristics of an adjacent pulse repetition interval length as a scale for length , 2013 .

[31]  Dong Wei,et al.  Synthetic adjacent pulse repetition interval length method to solve integer ambiguity problem: theoretical analysis , 2013 .

[32]  Dong Wei,et al.  A study of the possibility of using an adjacent pulse repetition interval length as a scale using a Helium–Neon interferometer , 2013 .

[33]  K. Minoshima,et al.  High-accuracy correction of air refractive index by using two-color heterodyne interferometry of optical frequency combs , 2012 .

[34]  D. Wei,et al.  Comparison of length measurements provided by a femtosecond optical frequency comb. , 2014, Optics express.