Impact of optical coherence tomography scanning density on quantitative analyses in neovascular age-related macular degeneration

PurposeTo assess the influence of varying B-scan frame-sampling densities on retinal thickness and volume measurements from spectral domain optical coherence tomography (OCT) in eyes with neovascular age-related macular degeneration (AMD).MethodsVolume OCT data (512 × 128 macular cube over 6 × 6 mm) were collected from 39 eyes with neovascular AMD. All 128 B-scans in each image set were manually segmented, allowing quantification of the neurosensory retina, subretinal fluid (SRF), subretinal hyperreflective material (SRHM), and pigment epithelium detachment (PED). Thickness maps were generated for less dense subsets of scans, ranging from every other (64 B-scans) to every 64th (2 B-scans). For each less dense subset, foveal central subfield thickness and total macular volume (TMV) were compared with values obtained using all 128 scans (considered the reference).ResultsFor each parameter, the mean absolute difference compared with the reference increased with reducing B-scan density. However, these differences did not reach statistical significance until frame-sampling density was reduced to every eighth scan (ie, 16 B-scans spaced 375 μm apart) for neurosensory retina, and every fourth scan (ie, 32 B-scans spaced 188 μm apart) for SRF, SRHM, and PED. For neurosensory retina, the mean (% error) and maximum (% error) absolute differences in TMV were 0.02 mm3 (0.24%) and 0.06 mm3 (0.79%), respectively. Similarly, at a density of 32 B-scans, mean and maximum differences for SRF were 0.004 mm3 (3.47%) and 0.02 mm3 (22.22%), respectively. The mean differences for SRHM and PED were 0.01 mm3 (8.03%) and 0.01 mm3 (4.04%), respectively.ConclusionsA minimum of 16 equally spaced B-scans, covering a 6 × 6 mm area, appears necessary to generate retinal thickness measurements similar to those obtained using all 128 B-scans in eyes with choroidal neovascularization (CNV). When considering other CNV lesion features, a minimum of 16 B-scans for SRF and PED, and 32 B-scans for SRHM are required to generate volume maps similar to ground-truth values. These findings may have implications for the design of acquisition and grading protocols for clinical trials using OCT in neovascular AMD.

[1]  Christopher Kai-shun Leung,et al.  Alignment artifacts in optical coherence tomography analyzed images. , 2007, Ophthalmology.

[2]  R. Costa,et al.  Evaluation of image artifact produced by optical coherence tomography of retinal pathology. , 2005, American journal of ophthalmology.

[3]  S. Sadda,et al.  Relationship Between Subretinal Hyperreflective Material Reflectivity and Volume in Patients With Neovascular Age-Related Macular Degeneration Following Anti-Vascular Endothelial Growth Factor Treatment. , 2015, Ophthalmic surgery, lasers & imaging retina.

[4]  L. da Cruz,et al.  Bevacizumab for neovascular age related macular degeneration (ABC Trial): multicentre randomised double masked study , 2010, BMJ : British Medical Journal.

[5]  Miguel J Maldonado,et al.  Using optical coherence tomography to monitor photodynamic therapy in age related macular degeneration. , 2005, American journal of ophthalmology.

[6]  P. Keane,et al.  Relationship between optical coherence tomography retinal parameters and visual acuity in neovascular age-related macular degeneration. , 2008, Ophthalmology.

[7]  Paul G. Updike,et al.  Reproducibility of quantitative optical coherence tomography subanalysis in neovascular age-related macular degeneration. , 2007, Investigative ophthalmology & visual science.

[8]  Srinivas R Sadda,et al.  Impact of scanning density on measurements from spectral domain optical coherence tomography. , 2010, Investigative ophthalmology & visual science.

[9]  L. Aiello,et al.  Ocular Coherence Tomography and Diabetic Eye Disease , 2010, Seminars in ophthalmology.

[10]  Giovanni Staurenghi,et al.  ARTIFACTS IN AUTOMATIC RETINAL SEGMENTATION USING DIFFERENT OPTICAL COHERENCE TOMOGRAPHY INSTRUMENTS , 2010, Retina.

[11]  Ziqiang Wu,et al.  Error correction and quantitative subanalysis of optical coherence tomography data using computer-assisted grading. , 2007, Investigative ophthalmology & visual science.

[12]  H. Hosseini,et al.  EFFECT OF MACULAR EDEMA ON OPTICAL COHERENCE TOMOGRAPHY SIGNAL STRENGTH , 2010, Retina.

[13]  M. Sonka,et al.  Automated segmentation of the choroid from clinical SD-OCT. , 2012, Investigative ophthalmology & visual science.

[14]  Srinivas R Sadda,et al.  Evaluation of optical coherence tomography retinal thickness parameters for use in clinical trials for neovascular age-related macular degeneration. , 2009, Investigative ophthalmology & visual science.

[15]  P. Keane,et al.  Effects of retinal morphology on contrast sensitivity and reading ability in neovascular age-related macular degeneration. , 2010, Investigative ophthalmology & visual science.

[16]  Giovanni Gregori,et al.  Macular thickness measurements in normal eyes using spectral domain optical coherence tomography. , 2007, Ophthalmic surgery, lasers & imaging : the official journal of the International Society for Imaging in the Eye.

[17]  R. Zawadzki,et al.  High-resolution Fourier-domain optical coherence tomography of choroidal neovascular membranes associated with age-related macular degeneration. , 2010, Investigative ophthalmology & visual science.

[18]  Srinivas R Sadda,et al.  Optical Coherence Tomography in the Diagnosis and Management of Diabetic Retinopathy , 2009, International ophthalmology clinics.

[19]  Glenn J Jaffe,et al.  Ranibizumab and bevacizumab for neovascular age-related macular degeneration. , 2011, The New England journal of medicine.

[20]  Adnan Tufail,et al.  Segmentation error in Stratus optical coherence tomography for neovascular age-related macular degeneration. , 2009, Investigative ophthalmology & visual science.

[21]  Milan Sonka,et al.  Validity of Automated Choroidal Segmentation in SS-OCT and SD-OCT. , 2015, Investigative ophthalmology & visual science.

[22]  Robert J Zawadzki,et al.  Clinical application of rapid serial fourier-domain optical coherence tomography for macular imaging. , 2006, Ophthalmology.

[23]  Christian Ahlers,et al.  EVALUATION OF SEGMENTATION PROCEDURES USING SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY IN EXUDATIVE AGE-RELATED MACULAR DEGENERATION , 2011, Retina.

[24]  F. Ferris,et al.  Age-related macular degeneration and blindness due to neovascular maculopathy. , 1984, Archives of ophthalmology.

[25]  Darrell E Baskin,et al.  Optical coherence tomography in diabetic macular edema , 2010, Current opinion in ophthalmology.

[26]  S. Sadda,et al.  Effect of OCT volume scan density on thickness measurements in diabetic macular edema , 2011, Eye.

[27]  L. Labree,et al.  Errors in retinal thickness measurements obtained by optical coherence tomography. , 2006, Ophthalmology.

[28]  P. Keane,et al.  Impact of scanning density on spectral domain optical coherence tomography assessments in neovascular age‐related macular degeneration , 2012, Acta ophthalmologica.