Methodological considerations for kinematic analysis of upper limbs in healthy and poststroke adults Part II: a systematic review of motion capture systems and kinematic metrics

ABSTRACT Background and purpose: To review the methods used to analyze the kinematics of upper limbs (ULs) of healthy and poststroke adults, namely the motion capture systems and kinematic metrics. Summary of review: A database of articles published in the last decade was compiled using the following search terms combinations: (“upper extremity” OR “upper limb” OR arm) AND (kinematic OR motion OR movement) AND (analysis OR assessment OR measurement). The articles included in this review: (1) had the purpose to analyze objectively three-dimension kinematics of ULs, (2) studied functional movements or activities of daily living involving ULs, and (3) studied healthy and/or poststroke adults. Fourteen articles were included (four studied a healthy sample, three analyzed poststroke patients, and seven examined both poststroke and healthy participants). Conclusion: Most articles used optoelectronic systems with markers; however, the presentation of laboratory and task-specific errors is missing. Markerless systems, used in some studies, seem to be promising alternatives for implementation of kinematic analysis in hospitals and clinics, but the literature proving their validity is scarce. Most articles analyzed “joint kinematics” and “end-point kinematics,” mainly related with reaching. The different stroke locations of the samples were not considered in their analysis and only three articles described their psychometric properties. Implication of key findings: Future research should validate portable motion capture systems, document their specific error at the acquisition place and for the studied task, include grasping and manipulation analysis, and describe psychometric properties.

[1]  James A. Johnson,et al.  Accuracy of an electromagnetic tracking device: a study of the optimal range and metal interference. , 1996, Journal of biomechanics.

[2]  Paul R. Cohen,et al.  Camera Calibration with Distortion Models and Accuracy Evaluation , 1992, IEEE Trans. Pattern Anal. Mach. Intell..

[3]  Joaquim Gabriel,et al.  Towards a detailed anthropometric body characterization using the Microsoft Kinect. , 2016, Technology and health care : official journal of the European Society for Engineering and Medicine.

[4]  Miguel Fernando Paiva Velhote Correia,et al.  Methodological considerations for kinematic analysis of upper limbs in healthy and poststroke adults. Part I: A systematic review of sampling and motor tasks , 2018, Topics in stroke rehabilitation.

[5]  Pamela W. Duncan,et al.  Issues in selecting outcome measures to assess functional recovery after stroke , 2006, NeuroRX.

[6]  Ronglei Sun,et al.  Kinematic analysis and dexterity evaluation of upper extremity in activities of daily living. , 2010, Gait & posture.

[7]  K. Sunnerhagen,et al.  Kinematic Variables Quantifying Upper-Extremity Performance After Stroke During Reaching and Drinking From a Glass , 2011, Neurorehabilitation and neural repair.

[8]  Koji Nakamaru,et al.  Three-dimensional motion of the upper extremity joints during various activities of daily living. , 2010, Journal of biomechanics.

[9]  C. Patten,et al.  Reproducibility and Minimal Detectable Change of Three-Dimensional Kinematic Analysis of Reaching Tasks in People With Hemiparesis After Stroke , 2008, Physical Therapy.

[10]  N. Black,et al.  The feasibility of creating a checklist for the assessment of the methodological quality both of randomised and non-randomised studies of health care interventions. , 1998, Journal of epidemiology and community health.

[11]  H. Seelen,et al.  Evaluation of upper extremity motor function tests in tetraplegics , 2002, Spinal Cord.

[12]  Markus Windolf,et al.  Systematic accuracy and precision analysis of video motion capturing systems--exemplified on the Vicon-460 system. , 2008, Journal of biomechanics.

[13]  Antonio I Cuesta-Vargas,et al.  The use of inertial sensors system for human motion analysis , 2010, Physical therapy reviews : PTR.

[14]  Enrique J. Gómez,et al.  Upper Limb Portable Motion Analysis System Based on Inertial Technology for Neurorehabilitation Purposes , 2010, Sensors.

[15]  K. Sunnerhagen,et al.  Movement Kinematics During a Drinking Task Are Associated With the Activity Capacity Level After Stroke , 2012, Neurorehabilitation and neural repair.

[16]  B. Rosen,et al.  A functional MRI study of subjects recovered from hemiparetic stroke. , 1997, Stroke.

[17]  Philippe Gorce,et al.  Biomechanical analysis of upper limb during the use of touch screen: motion strategies identification , 2017, Ergonomics.

[18]  Sandeep K Subramanian,et al.  Validity of Movement Pattern Kinematics as Measures of Arm Motor Impairment Poststroke , 2010, Stroke.

[19]  K. Sunnerhagen,et al.  Three Months After Stroke Responsiveness of Upper Extremity Kinematic Measures and Clinical Improvement During the First , 2013 .

[20]  Patric Eichelberger,et al.  Analysis of accuracy in optical motion capture - A protocol for laboratory setup evaluation. , 2016, Journal of biomechanics.

[21]  Steffi L. Colyer,et al.  A Review of the Evolution of Vision-Based Motion Analysis and the Integration of Advanced Computer Vision Methods Towards Developing a Markerless System , 2018, Sports Medicine - Open.

[22]  Ahmet H. Ertas,et al.  A clinically feasible kinematic assessment method of upper extremity motor function impairment after stroke , 2016 .

[23]  L. Goldstein Statewide Hospital-Based Stroke Services in North Carolina: Changes Over 10 Years , 2010, Stroke.

[24]  David Howard,et al.  Movement variability in stroke patients and controls performing two upper limb functional tasks: a new assessment methodology , 2009, Journal of NeuroEngineering and Rehabilitation.

[25]  Isabelle Laffont,et al.  The Contribution of Kinematics in the Assessment of Upper Limb Motor Recovery Early After Stroke , 2014, Neurorehabilitation and neural repair.

[26]  G. King,et al.  Accuracy of an electromagnetic tracking device: a study of the optimal range and metal interference. , 1996, Journal of biomechanics.

[27]  Won-Kyung Song,et al.  Kinematic analysis of upper extremity movement during drinking in hemiplegic subjects. , 2014, Clinical biomechanics.

[28]  S. Combs,et al.  Comparison of “Less Affected Limb” Reaching Kinematics in Individuals with Chronic Stroke and Healthy Age-Matched Controls , 2012 .

[29]  A. Fugl-Meyer,et al.  The post-stroke hemiplegic patient. 1. a method for evaluation of physical performance. , 1975, Scandinavian journal of rehabilitation medicine.

[30]  Leonid Churilov,et al.  Standardized measurement of sensorimotor recovery in stroke trials: Consensus-based core recommendations from the Stroke Recovery and Rehabilitation Roundtable , 2017, International journal of stroke : official journal of the International Stroke Society.

[31]  Jaap Harlaar,et al.  Complete 3D kinematics of upper extremity functional tasks. , 2008, Gait & posture.

[32]  D. V. Vander Linden,et al.  Reproducibility and accuracy of angle measurements obtained under static conditions with the Motion Analysis video system. , 1992, Physical therapy.

[33]  R. Lyle A performance test for assessment of upper limb function in physical rehabilitation treatment and research , 1981, International journal of rehabilitation research. Internationale Zeitschrift fur Rehabilitationsforschung. Revue internationale de recherches de readaptation.

[34]  J. Cunha,et al.  Movement Quantification in Neurological Diseases: Methods and Applications. , 2016, IEEE reviews in biomedical engineering.

[35]  B. Bussel,et al.  Motor compensation and recovery for reaching in stroke patients , 2003, Acta neurologica Scandinavica.

[36]  H. M. Karara,et al.  Direct Linear Transformation from Comparator Coordinates into Object Space Coordinates in Close-Range Photogrammetry , 2015 .

[37]  A. Clark,et al.  Is Cardiorespiratory Fitness Related to Cardiometabolic Health and All-Cause Mortality Risk in Patients with Coronary Heart Disease? A CARE CR Study , 2018, Sports Medicine - Open.

[38]  Stefano Rossi,et al.  Effects of the calibration procedure on the metrological performances of stereophotogrammetric systems for human movement analysis , 2017 .

[39]  M. Woollacott,et al.  Motor Control: Translating Research into Clinical Practice , 2006 .

[40]  Stefano Rossi,et al.  Technical quality assessment of an optoelectronic system for movement analysis , 2015 .

[41]  Diego Torricelli,et al.  Quantitative assessment based on kinematic measures of functional impairments during upper extremity movements: A review. , 2014, Clinical biomechanics.

[42]  L. Richards,et al.  Reliability of Upper Extremity Kinematics While Performing Different Tasks in Individuals With Stroke , 2011, Journal of motor behavior.

[43]  M. Woollacott,et al.  Comprar Motor Control. Translating Research Into Clinical Practice (International Edition) 5th Ed. | Anne Shumway-Cook | 9781496347725 | Lippincott Williams & Wilkins , 2016 .

[44]  Steven C Cramer,et al.  Biomarkers of Stroke Recovery: Consensus-Based Core Recommendations from the Stroke Recovery and Rehabilitation Roundtable* , 2017, Neurorehabilitation and neural repair.

[45]  O. Celik,et al.  Systematic review of Kinect applications in elderly care and stroke rehabilitation , 2014, Journal of NeuroEngineering and Rehabilitation.

[46]  D. Moher,et al.  Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. , 2010, International journal of surgery.

[47]  N McKoy,et al.  Systems to rate the strength of scientific evidence. , 2002, Evidence report/technology assessment.