Tandem Mass Spectrometry of Small, Multiply Charged Oligonucleotides

Multiply charged anions derived from electrospray ionization of the sodium salts of various small oligonucleotides (n = 4−8) have been subjected to tandem mass spectrometry (MS/MS) in a quadrupole ion trap. All ions were observed to dissociate with high efficiencies even under conditions not ordinarily conducive for the observance of high MS/MS efficiency. Large fractions of the total product ion signal could be attributed to single-cleavage reactions with the parent ion charge shared among the two product ions in various combinations. In every case, the most facile reaction was observed to be the loss of the adenine anion. This reaction was then observed to be followed by cleavage of the 3′ C–O bond of phosphodiester linkage of the sugar from which the adenine had been lost.

[1]  J. Schwartz,et al.  High resolution on a quadrupole ion trap mass spectrometer , 1991, Journal of the American Society for Mass Spectrometry.

[2]  M. Karas,et al.  Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons. , 1988, Analytical chemistry.

[3]  J. Fenn,et al.  Multiple charging in electrospray ionization of poly(ethylene glycols) , 1988 .

[4]  W. E. Reynolds,et al.  Recent improvements in and analytical applications of advanced ion trap technology , 1984 .

[5]  R. Cooks,et al.  Extending the mass range of the quadrupole ion trap using axial modulation , 1989 .

[6]  J. J. Conboy,et al.  Atmospheric pressure ionization mass spectrometry. Detection for the separation sciences. , 1990 .

[7]  J. Henion,et al.  The determination of protein, oligonucleotide and peptide molecular weights by ion-spray mass spectrometry. , 1988, Rapid communications in mass spectrometry : RCM.

[8]  K. Tomer,et al.  Fast atom bombardment combined with tandem mass spectrometry for determining structures of small oligonucleotides. , 1987, Analytical Biochemistry.

[9]  H. Budzikiewicz Selected reviews on mass spectrometric topics: Nucleosides and nucleotides , 1985 .

[10]  John B. Fenn,et al.  Electrospray ionization–principles and practice , 1990 .

[11]  M. Gross,et al.  Fast atom bombardment combined with tandem mass spectrometry for the study of dinucleotides. , 1986, Analytical biochemistry.

[12]  R. Cooks,et al.  Characterization of an alkylated dinucleotide by desorption chemical ionization and tandem mass spectrometry. , 1987, Biomedical & environmental mass spectrometry.

[13]  C. McNeal The role of ion induced mass spectrometry in modern biochemical problems , 1982 .

[14]  K. Tomer,et al.  Fast atom bombardment combined with tandem mass spectrometry for the determination of nucleosides. , 1984, Analytical biochemistry.

[15]  M. Mann Electrospray: Its potential and limitations as an ionization method for biomolecules , 1990 .

[16]  H. Hsiung,et al.  Sequence determination of protected oligodeoxyribonucleotides containing phosphotriester linkages by californium-252 plasma desorption mass spectrometry. , 1980, Proceedings of the National Academy of Sciences of the United States of America.

[17]  G. Sindona,et al.  Bioorganic applications of mass spectrometry. 3. Fast-atom-bombardment-induced zwitterionic oligonucleotide quasimolecular ions sequenced by MS/MS , 1983 .

[18]  C. G. Edmonds,et al.  New developments in biochemical mass spectrometry: electrospray ionization. , 1990, Analytical chemistry.

[19]  M. Mann,et al.  Of protons or proteins , 1988 .

[20]  G. Glish,et al.  Multiple stages of mass spectrometry in a quadrupole ion trap mass spectrometer : prerequisites , 1991 .

[21]  R. Cooks,et al.  Instrumentation, applications, and energy deposition in quadrupole ion-trap tandem mass spectrometry , 1987 .

[22]  G. Glish,et al.  Selective ion isolation/rejection over a broad mass range in the quadrupole ion trap , 1991, Journal of the American Society for Mass Spectrometry.

[23]  G. Glish,et al.  Atmospheric Sampling Glow Discharge Ionization Source for the Determination of Trace Organic Compounds in Ambient Air , 1988 .

[24]  G. Glish,et al.  Coupling of an atmospheric-samling ion source with an ion-trap mass spectrometer , 1989 .

[25]  K. Schram,et al.  Fast atom Bombardment Mass Spectrometry of Nucleosides, Nucleotides and Oligonucleotides , 1985 .

[26]  M. Mann,et al.  Interpreting mass spectra of multiply charged ions , 1989 .

[27]  P. H. Hemberger,et al.  Mass range extension in a quadrupole ion‐trap mass spectrometer , 1989 .

[28]  P. Roepstorff,et al.  Proposal for a common nomenclature for sequence ions in mass spectra of peptides. , 1984, Biomedical mass spectrometry.

[29]  M. Mann,et al.  Electrospray ionization for mass spectrometry of large biomolecules. , 1989, Science.

[30]  G. Glish,et al.  Electrospray ionization combined with ion trap mass spectrometry , 1990 .

[31]  J. Henion,et al.  Ion Spray Liquid Chromatography/Ion Trap Mass Spectrometry Determination of Biomolecules , 1991 .

[32]  A. Viari,et al.  Sequence analysis of unprotected tri‐deoxyribonucleoside diphosphates by 252Cf‐plasma desorption mass spectrometry , 1987 .

[33]  F. McLafferty,et al.  Electrospray ionization with Fourier‐transform mass spectrometry. Charge state assignment from resolved isotopic peaks , 1990 .