Whole-body low-dose multidetector row-CT in the diagnosis of multiple myeloma: an alternative to conventional radiography.

OBJECTIVE The goal of this study was to establish the feasibility of a low-dose whole-body multidetector row-CT (MDCT) protocol in the diagnosis of multiple myeloma (MM), as an alternative to conventional X-ray imaging, which is currently still state-of-the-art in these patients, with emphasis on the comparison of image resolution on axial and multiplanar reformatted (MPR) scans and reduction of radiation dose. MATERIAL AND METHODS 100 patients with known MM, or monoclonal gammopathy of unknown significance (MGUS) underwent unenhanced whole-body MDCT on a 16-slice scanner in a randomised fashion, using a 16 x 1.5 mm collimation and four different energy parameters (40, 50, 60 and 70 mAs). Three different reconstruction algorithms were used in every patient (B40f, B50f and B60f kernel). CT scans were reviewed independently by two radiologists, with regard to correct classification into one of the three known MM stages, and recognition of fracture risk. Thereafter, axial and MPR images were evaluated in consensus by both readers, with respect to image resolution. Diagnosis of osteolytic lesions was performed on the basis of axial and multiplanar reformatted images, whereas the assessment of spinal misalignment and fracture was done only on MPR images. The distribution of image resolution categories (very good, good, sufficient, insufficient for diagnosis) was evaluated depending on following parameters: current time product, patient's weight, bone density and reconstruction algorithm. The effective radiation dose was determined with the aid of an anthropomorphic Alderson Rando-Phantom, using a tube current time product of 40 mAs, and then extrapolating it on all current time products applied in this study on a commercially available software program WinDose (Institute of Medical Physics, Erlangen, Germany). RESULTS In all 100 patients, image resolution was diagnostic, regardless of scanning parameters, enabling correct classification of multiple myeloma patients. Image quality of MPR images was either equal or inferior to correspondent axial images in the delineation of smaller lytic lesions, because of the use of non-isotropic voxel size. However, they proved accurate in diagnosing fracture and spine misalignment. A strong dependency of image resolution on bone density was observed, with reduced quality in patients with either diffuse skeleton infiltration or concurrent osteoporosis. Spatial resolution was also dependent on the reconstruction algorithm and energy level (mAs) used, as well as on patient's weight, but their influence was low within the given ranges. A middle-frequency reconstruction algorithm (B50f kernel) proved beneficial for all energy protocols. The interobserver agreement was excellent (kappa = 0.95) for classification of MM-patients. Effective radiation dose of MDCT calculated at a tube current time product of 40 mAs was 1.7-fold higher than the mean radiation dose of conventional X-ray (4.1 mSv versus 2.4 mSv). DISCUSSION Our study shows that whole-body low-dose MDCT investigational protocols are appropriate for the diagnosis of lytic bone changes and for assessment of fracture risk in multiple myeloma patients, representing a serious alternative to current standards.

[1]  R. Daffner,et al.  MRI in the detection of malignant infiltration of bone marrow. , 1986, AJR. American journal of roentgenology.

[2]  S. Salmon,et al.  A clinical staging system for multiple myeloma correlation of measured myeloma cell mass with presenting clinical features, response to treatment, and survival , 1975, Cancer.

[3]  N. Müller,et al.  Low-dose high-resolution CT of lung parenchyma. , 1991, Radiology.

[4]  M. Boccadoro,et al.  Diagnosis, prognosis, and standard treatment of multiple myeloma. , 1997, Hematology/oncology clinics of North America.

[5]  W. Hayes,et al.  Predicting pathologic fracture risk in the management of metastatic bone defects. , 1995, Clinical orthopaedics and related research.

[6]  R. Kyle,et al.  Myeloma : biology and management , 1995 .

[7]  M. Reiser,et al.  MRI gadolinium enhancement of bone marrow: age-related changes in normals and in diffuse neoplastic infiltration , 1997, Skeletal Radiology.

[8]  B. Maldague,et al.  Skeletal survey in advanced multiple myeloma: radiographic versus MR imaging survey , 1999, British journal of haematology.

[9]  B. Maldague,et al.  Development of vertebral fractures in patients with multiple myeloma: does MRI enable recognition of vertebrae that will collapse? , 1998, Journal of computer assisted tomography.

[10]  K. Remes,et al.  The value of magnetic resonance imaging in screening myeloma lesions of the lumbar spine , 1995, British journal of haematology.

[11]  H. Lokhorst,et al.  Comparison of plasma cell infiltration in bone marrow biopsies and aspirates in patients with multiple myeloma , 1992, British journal of haematology.

[12]  M. Reiser,et al.  Magnetic resonance imaging as a supplement for the clinical staging system of Durie and Salmon? , 2002, Cancer.

[13]  H. Libshitz,et al.  Multiple myeloma: appearance at MR imaging. , 1992, Radiology.

[14]  L. Martí-Bonmatí,et al.  MR imaging of a case of adenomatoid tumor of the adrenal gland , 1999, European Radiology.

[15]  R A McLeod,et al.  Multiple myeloma: evaluation by CT. , 1985, Radiology.

[16]  R W Günther,et al.  Multidetector CT of the spine in multiple myeloma: comparison with MR imaging and radiography. , 2002, AJR. American journal of roentgenology.

[17]  J E Aldrich,et al.  Chronic infiltrative lung disease: comparison of diagnostic accuracies of radiography and low- and conventional-dose thin-section CT. , 1994, Radiology.

[18]  R. Alexanian Localized and indolent myeloma. , 1980, Blood.

[19]  H. Döhner,et al.  Magnetic resonance imaging of bone marrow in lymphoproliferative disorders: correlation with bone marrow biopsy , 1989, British journal of haematology.

[20]  T. Kurki,et al.  Low-dose and conventional-dose high resolution CT of pulmonary changes in breast cancer patients treated by tangential field radiotherapy. , 1995, European journal of radiology.

[21]  R. Sievert,et al.  Book Reviews : Recommendations of the International Commission on Radiological Protection (as amended 1959 and revised 1962). I.C.R.P. Publication 6. 70 pp. PERGAMON PRESS. Oxford, London and New York, 1964. £1 5s. 0d. [TB/54] , 1964 .

[22]  B. Schmidt,et al.  A PC program for estimating organ dose and effective dose values in computed tomography , 1999, European Radiology.