Influence of cage design on interbody fusion in a sheep cervical spine model.

OBJECT The purpose of this study was to compare the characteristics of interbody fusion achieved using an autologous tricortical iliac crest bone graft with those of a cylinder- and a box-design cage in a sheep cervical spine model. This study was designed to determine whether there are differences between three interbody fusion procedures in: 1) ability to preserve postoperative distraction; 2) biomechanical stability; and 3) histological characteristics of intervertebral bone matrix formation. METHODS Twenty-four sheep underwent C3-4 discectomy and fusion in which the following were used: Group 1, autologous tricortical iliac crest bone graft (eight sheep); Group 2, titanium cylinder-design cage filled with autologous iliac crest bone graft (eight sheep); and Group 3, titanium box-design cage filled with autologous iliac crest graft (eight sheep). Radiography was performed pre- and postoperatively and after 1, 2, 4, 8, and 12 weeks. At the same time points, disc space height, intervertebral angle, and lordosis angle were measured. After 12 weeks, the sheep were killed, and fusion sites were evaluated by obtaining functional radiographs in flexion and extension. Quantitative computerized tomography scans were acquired to assess bone mineral density, bone mineral content, and bone callus volume. Biomechanical testing was performed in flexion, extension, axial rotation, and lateral bending. Stiffness, range of motion, neutral zone, and elastic zone were determined. Histomorphological and histomorphometric analyses were performed, and polychrome sequential labeling was used to determine the time frame of new bone formation. Over a 12-week period significantly higher values for disc space height and intervertebral angle were shown in cage-treated sheep than in those that received bone graft. Functional radiographic assessment revealed significantly lower residual flexion-extension movement in sheep with the cylinder cage-fixed spines than in those that received bone graft group. The cylinder-design cages showed significantly higher values for bone mineral content, bone callus content, and stiffness in axial rotation and lateral bending than the other cages or grafts. Histomorphometric evaluation and polychrome sequential labeling showed a more progressed bone matrix formation in the cylindrical cage group than in both other groups. CONCLUSIONS Compared with the tricortical bone graft, both cages showed significantly better distractive properties. The cylindrical cage demonstrated a significantly higher biomechanical stiffness and an accelerated interbody fusion compared with the box-design cage and the tricortical bone graft. The differences in bone matrix formation within both cages were the result of the significantly lower stress shielding on the bone graft by the cylinder-design cage.

[1]  W C Hutton,et al.  Transfacet screws with lumbar interbody reconstruction: biomechanical study of motion segment stiffness. , 1996, Journal of spinal disorders.

[2]  R. Holt,et al.  Anterior cervical reconstruction using titanium cages with anterior plating. , 1999, Spine.

[3]  R. Fraser,et al.  Bony and Vascular Anatomy of the Normal Cervical Spine in the Sheep , 1995, Spine.

[4]  B. Cunningham,et al.  Osteogenic protein versus autologous interbody arthrodesis in the sheep thoracic spine. A comparative endoscopic study using the Bagby and Kuslich interbody fusion device. , 1999, Spine.

[5]  B. J. Doherty,et al.  Interspace distraction and graft subsidence after anterior lumbar fusion with femoral strut allograft. , 1993, Spine.

[6]  R. Delamarter,et al.  Distractive Properties of a Threaded Interbody Fusion Device: An In Vivo Model , 1996, Spine.

[7]  B. Cunningham,et al.  Interbody Lumbar Fusion Using a Carbon Fiber Cage Implant Versus Allograft Bone: An Investigational Study in the Spanish Goat , 1994, Spine.

[8]  B. Weiner,et al.  Lumbar Interbody Cages , 1998, Spine.

[9]  Cloward Rb The anterior surgical approach to the cervical spine: the cloward procedure: past, present, and future ― The presidential guest lecture, cervical spine research society , 1988 .

[10]  G. Matgé Anterior Interbody Fusion with the BAK-Cage in Cervical Spondylosis , 1998, Acta Neurochirurgica.

[11]  T A Zdeblick,et al.  Spinal instrumentation for metastatic disease: in vitro biomechanical analysis. , 1993, Journal of spinal disorders.

[12]  M. Markel,et al.  Cervical Interbody Fusion Cages: An Animal Model With and Without Bone Morphogenetic Protein , 1998, Spine.

[13]  T. Mittlmeier,et al.  Stage-related surgery for cervical spine instability in rheumatoid arthritis , 1999, European Spine Journal.

[14]  L. Nolte,et al.  The role of supplemental translaminar screws in anterior lumbar interbody fixation: a biomechanical study , 1998, European Spine Journal.

[15]  N S Brooke,et al.  Preliminary experience of carbon fibre cage prostheses for treatment of cervical spine disorders. , 1997, British journal of neurosurgery.

[16]  L. Claes,et al.  Stabilizing effect of posterior lumbar interbody fusion cages before and after cyclic loading. , 1999, Journal of neurosurgery.

[17]  A. Tencer,et al.  Biomechanical Properties of Threaded Inserts for Lumbar Interbody Spinal Fusion , 1995, Spine.

[18]  B. Weiner,et al.  Erratum: 'Spine update: Lumbar interbody cages' (Spine (1998) 23 (634- 640)) , 1998 .

[19]  A. Thambyah,et al.  Influence of PLIF Cage Size on Lumbar Spine Stability , 2000, Spine.

[20]  Thomas R. Oxland,et al.  Interbody cage stabilisation in the lumbar spine: biomechanical evaluation of cage design, posterior instrumentation and bone density , 1998 .

[21]  F. Muñoz,et al.  Comparison of three techniques of anterior fusion in single-level cervical disc herniation , 1998, European Spine Journal.

[22]  L. Nolte,et al.  A Comparative Biomechanical Investigation of Anterior Lumbar Interbody Cages: Central and Bilateral Approaches* , 2000, The Journal of bone and joint surgery. American volume.

[23]  N. Yoganandan,et al.  Biomechanical Analysis of Thoracolumbar Interbody Constructs: How Important Is the Endplate? , 1996, Spine.

[24]  J. Cholewicki,et al.  Multidirectional stabilizing potential of BAK interbody spinal fusion system for anterior surgery. , 1997, Journal of spinal disorders.

[25]  A. Patwardhan,et al.  Load-Carrying Capacity of the Human Cervical Spine in Compression Is Increased Under a Follower Load , 2000, Spine.

[26]  K. Kaneda,et al.  In vitro biomechanical investigation of the stability and stress-shielding effect of lumbar interbody fusion devices. , 2000, Journal of neurosurgery.

[27]  P. A. Cripton,et al.  Compressive strength of interbody cages in the lumbar spine: the effect of cage shape, posterior instrumentation and bone density , 1998, European Spine Journal.

[28]  T A Zdeblick,et al.  Biomechanical Comparison of Posterior Lumbar Interbody Fusion Cages , 1997, Spine.

[29]  D N Kunz,et al.  Posterior Lumbar Interbody Fusion: A Biomechanical Comparison, Including a New Threaded Cage , 1997, Spine.

[30]  J. Brantigan,et al.  A Carbon Fiber Implant to Aid Interbody Lumbar Fusion: Mechanical Testing , 1991, Spine.

[31]  R. Watkins,et al.  Comparison of Disc Space Heights after Anterior Lumbar Interbody Fusion , 1989, Spine.

[32]  T. Mittlmeier,et al.  Comparison Between Sheep and Human Cervical Spines: An Anatomic, Radiographic, Bone Mineral Density, and Biomechanical Study , 2001, Spine.

[33]  N Yoganandan,et al.  Finite element analysis of anterior cervical spine interbody fusion. , 1997, Bio-medical materials and engineering.

[34]  Marcy Wong,et al.  Mechanical stresses and endochondral ossification in the chondroepiphysis , 1988, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[35]  T. Mittlmeier,et al.  Biomechanical Assessment of Transoral Plate Fixation for Atlantoaxial Instability , 2000, Spine.

[36]  E H Burger,et al.  Mechanical stress and osteogenesis in vitro , 1992, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[37]  H. An,et al.  Biomechanical effect of anterior grafting devices on the rotational stability of spinal constructs. , 2000, Journal of spinal disorders.

[38]  J. Brantigan,et al.  A carbon fiber implant to aid interbody lumbar fusion. Two-year clinical results in the first 26 patients. , 1993 .