UV inactivation, liquid-holding recovery, and photoreactivation of Escherichia coli O157 and other pathogenic Escherichia coli strains in water.

Drinking water, water used in food production and for irrigation, water for fish farming, waste water, surface water, and recreational water have been recently recognized as a vector for the transmission of pathogenic Escherichia coli, especially serotype O157:H7. We investigated the UV (253.7 nm) inactivation behavior and the capability of dark repair (liquid-holding recovery) and photoreactivation of seven pathogenic (including three enterohemorrhagic E. coli) strains and one nonpathogenic strain of E. coli (ATCC 11229) with respect to the use of UV light for water disinfection purposes. Because most bacteria and yeast are known to be able to repair UV damage in their nucleic acids, repair mechanisms have to be considered to ensure safe water disinfection. We found a wide divergence in the UV susceptibility within the strains tested. A 6-log reduction of bacteria that fulfills the requirement for safe water disinfection was reached for the very most susceptible strain O157:H7 (CCUG 29199) at a UV fluence of 12 J/m2, whereas for the most resistant strain, O25:K98:NM, a UV fluence of about 125 J/m2 was needed. Except for one strain (O50:H7) liquid-holding recovery did not play an important role in recovery after UV irradiation. By contrast, all strains, particularly strains O25:K98:NM, O78:K80:H12, and O157:H7 (CCUG 29193), demonstrated photorepair ability. For a 6-log reduction of these strains, a UV fluence (253.7 nm) up to 300 J/m2 is required. The results reveal that the minimum fluence of 400 J/m2 demanded in the Austrian standard for water disinfection is sufficient to inactivate pathogenic E. coli. A fluence of 160 J/m2 (recommendation in Norway) or 250 J/m2 (recommendation in Switzerland) cannot be regarded as safe in that respect.

[1]  T. Hirata,et al.  Photoreactivation of enterohemorrhagic Escherichia coli following UV disinfection , 1999 .

[2]  W. Harm EFFECTS OF DOSE FRACTIONATION ON ULTRAVIOLET SURVIVAL OF ESCHERICHIA COLI , 1968, Photochemistry and photobiology.

[3]  N. Strockbine,et al.  Escherichia coli O157:H7 from water. , 1989, Lancet.

[4]  A. Cabaj,et al.  Influence of lamp intensity and water transmittance on the UV disinfection of water , 1997 .

[5]  G. Schauberger,et al.  [UV-inactivation of microorganisms in water]. , 1989, Zentralblatt fur Hygiene und Umweltmedizin = International journal of hygiene and environmental medicine.

[6]  M. Doyle,et al.  Survival of enterohemorrhagic Escherichia coli O157:H7 in water. , 1998, Journal of food protection.

[7]  R. Clark,et al.  Chlorine inactivation of Escherichia coli O157:H7. , 1999, Emerging infectious diseases.

[8]  J. Wells,et al.  A Waterborne Outbreak in Missouri of Escherichia coli O157:H7 Associated with Bloody Diarrhea and Death , 1992, Annals of Internal Medicine.

[9]  S. Ohgaki,et al.  Assessment of photoreactivation following ultraviolet light disinfection , 1996 .

[10]  I. Gould,et al.  Waterborne outbreak of Escherichia coli 0157 , 1991, The Lancet.

[11]  V. Adams,et al.  Ultraviolet inactivation of selected bacteria and viruses with photoreactivation of the bacteria , 1987 .

[12]  G. J. Cunningham,et al.  VENTILATION OF OPERATING-THEATRES. , 1964, Lancet.

[13]  M. Kundi,et al.  Increased inactivation of Saccharomyces cerevisiae by protraction of UV irradiation , 1996, Applied and environmental microbiology.

[14]  N. Strockbine,et al.  ESCHERICHIA COLI 0157:H7 FROM WATER , 1989, The Lancet.

[15]  H. Liltved,et al.  Influence of liquid holding recovery and photoreactivation on survival of ultraviolet-irradiated fish pathogenic bacteria , 1996 .

[16]  A. Cabaj,et al.  Biodosimetry: Model calculations for u.v. water disinfection devices with regard to dose distributions , 1996 .

[17]  M. Doyle,et al.  An outbreak of Escherichia coli O157:H7 infections traced to jerky made from deer meat. , 1997 .

[18]  Robert Spieser,et al.  Handbuch für Beleuchtung , 1950 .

[19]  D. Schoenen,et al.  Comparison of three laboratory devices for UV-inactivation of microorganisms , 1995 .

[20]  M. Kaneko Chlorination of pathogenic E coli O157 , 1998 .

[21]  Regina Sommer,et al.  Evaluation of the Efficiency of a UV Plant for Drinking Water Disinfection , 1993 .