Local in vivo shimming using adaptive passive shim positioning.

A subject-specific local in vivo passive shimming method, focusing on the prefrontal and temporal regions, is proposed. The aim of the investigation is to show that subject variability exists in optimal passive shimming and that the proposed method can be effectively used to overcome these differences. A shimming structure capable of adjusting the position of the passive shims to within a millimeter resolution is built. The optimal shim positions for each individual subject are computed from obtained field map using a convex optimization algorithm. Passive shim experiments at predetermined fixed shim positions vs. individually adjusted shim positions were performed and compared. The results show that intersubject variability exists in the optimal shim positions and that the location-sensitive method proposed can be useful for improving main field homogeneity in vivo.

[1]  P Webb,et al.  Rapid, fully automatic, arbitrary‐volume in vivo shimming , 1991, Magnetic resonance in medicine.

[2]  Christian Schwarzbauer,et al.  An evaluation of the use of passive shimming to improve frontal sensitivity in fMRI , 2005, NeuroImage.

[3]  Josef Pfeuffer,et al.  Combined passive and active shimming for in vivo MR spectroscopy at high magnetic fields. , 2006, Journal of magnetic resonance.

[4]  G. Glover,et al.  Regularized higher‐order in vivo shimming , 2002, Magnetic resonance in medicine.

[5]  Peter Jezzard,et al.  Requirements for room temperature shimming of the human brain , 2006, Magnetic resonance in medicine.

[6]  Jorge Nocedal,et al.  An interior algorithm for nonlinear optimization that combines line search and trust region steps , 2006, Math. Program..

[7]  Kevin M Koch,et al.  Sample-specific diamagnetic and paramagnetic passive shimming. , 2006, Journal of magnetic resonance.

[8]  Christoph Juchem,et al.  Magnetic field homogenization of the human prefrontal cortex with a set of localized electrical coils , 2010, Magnetic resonance in medicine.

[9]  R Gruetter,et al.  Automatic, localized in Vivo adjustment of all first‐and second‐order shim coils , 1993, Magnetic resonance in medicine.

[10]  Gary H Glover,et al.  Mitigation of susceptibility‐induced signal loss in neuroimaging using localized shim coils , 2005, Magnetic resonance in medicine.

[11]  S. Crozier,et al.  A Magnetization Mapping Approach for Passive Shim Design in MRI , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[12]  R. Edelman,et al.  Magnetic resonance imaging (2) , 1993, The New England journal of medicine.

[13]  D. Hoult,et al.  Magnet field profiling: Analysis and correcting coil design , 1984, Magnetic resonance in medicine.

[14]  Thomas F. Coleman,et al.  An Interior Trust Region Approach for Nonlinear Minimization Subject to Bounds , 1993, SIAM J. Optim..

[15]  Mark Jenkinson,et al.  Optimization of static field homogeneity in human brain using diamagnetic passive shims , 2002, Magnetic resonance in medicine.

[16]  M. J. D. Powell,et al.  A fast algorithm for nonlinearly constrained optimization calculations , 1978 .

[17]  J. Schenck The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. , 1996, Medical physics.

[18]  Mark W. Schmidt,et al.  Fast Optimization Methods for L1 Regularization: A Comparative Study and Two New Approaches , 2007, ECML.