Modeling and optimization of printed spiral coils in air and muscle tissue environments

Printed spiral coils (PSC) are viable candidates for near field wireless power transmission to the next generation of prosthetic devices with extreme size constraints. Implantable devices need to be hermetically sealed in biocompatible materials and placed in conductive environment with high permittivity, which can affect the PSC characteristics. We have constructed a detailed model that includes the effects of surrounding environment on the PSC parasitic components and eventually on the power transfer efficiency. This model is combined with an iterative design method that starts with a set of realistic design constraints and ends with the optimal PSC geometries. This was applied to optimize the wireless link of a 1 cm2 implantable device operating at 13.56 MHz. Measurement results showed that optimized PSC pairs, coated with 0.3 mm of silicone, achieved 72.2% and 30.8% efficiencies at a face to face relative distance of 10 mm in the air and muscle environment respectively. The PSC which was optimized for air could only bear 21.8% efficiency in muscle, showing that considering the PSC surrounding environment in the design process can result in nearly 10% improvement in the power transfer efficiency.

[1]  Stephen P. Boyd,et al.  Simple accurate expressions for planar spiral inductances , 1999, IEEE J. Solid State Circuits.

[2]  Klaus Finkenzeller,et al.  Book Reviews: RFID Handbook: Fundamentals and Applications in Contactless Smart Cards and Identification, 2nd ed. , 2004, ACM Queue.

[3]  Gislin Dagnelie,et al.  Visual perception in a blind subject with a chronic microelectronic retinal prosthesis , 2003, Vision Research.

[4]  Spartak Gevorgian,et al.  Basic parameters of coplanar-strip waveguides on multilayer dielectric/semiconductor substrates. Part 2: Low permittivity superstrates , 2003 .

[5]  Steven Brebels,et al.  Accurate modeling of high-Q spiral inductors in thin-film multilayer technology for wireless telecommunication applications , 2001 .

[6]  N. M. Ibrahim,et al.  Analysis of current crowding effects in multiturn spiral inductors , 2001 .

[7]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[8]  H. A. Wheeler Formulas for the Skin Effect , 1942, Proceedings of the IRE.

[9]  Spartak Gevorgian,et al.  Application notes - basic parameters of coplanar-strip waveguides on multilayer dielectric/semiconductor substrates, Part 1: high permittivity superstrates , 2003 .

[10]  Maysam Ghovanloo,et al.  Design and Optimization of Printed Spiral Coils for Efficient Transcutaneous Inductive Power Transmission , 2007, IEEE Transactions on Biomedical Circuits and Systems.

[11]  C.M. Zierhofer,et al.  Geometric approach for coupling enhancement of magnetically coupled coils , 1996, IEEE Transactions on Biomedical Engineering.

[12]  G. Lazzi,et al.  Thermal effects of bioimplants , 2005, IEEE Engineering in Medicine and Biology Magazine.