Noise performance of low-dose CT: comparison between an energy integrating detector and a photon counting detector using a whole-body research photon counting CT scanner

Abstract. Photon counting detector (PCD)-based computed tomography (CT) is an emerging imaging technique. Compared to conventional energy integrating detector (EID)-based CT, PCD-CT is able to exclude electronic noise that may severely impair image quality at low photon counts. This work focused on comparing the noise performance at low doses between the PCD and EID subsystems of a whole-body research PCD-CT scanner, both qualitatively and quantitatively. An anthropomorphic thorax phantom was scanned, and images of the shoulder portion were reconstructed. The images were visually and quantitatively compared between the two subsystems in terms of streak artifacts, an indicator of the impact of electronic noise. Furthermore, a torso-shaped water phantom was scanned using a range of tube currents. The product of the noise and the square root of the tube current was calculated, normalized, and compared between the EID and PCD subsystems. Visual assessment of the thorax phantom showed that electronic noise had a noticeably stronger degrading impact in the EID images than in the PCD images. The quantitative results indicated that in low-dose situations, electronic noise had a noticeable impact (up to a 5.8% increase in magnitude relative to quantum noise) on the EID images, but negligible impact on the PCD images.

[1]  K. Stierstorfer,et al.  Weighted FBP--a simple approximate 3D FBP algorithm for multislice spiral CT with good dose usage for arbitrary pitch. , 2004, Physics in medicine and biology.

[2]  B. Whiting,et al.  Validation of CT dose-reduction simulation. , 2008, Medical physics.

[3]  E. Ritman,et al.  Human Imaging With Photon Counting–Based Computed Tomography at Clinical Dose Levels: Contrast-to-Noise Ratio and Cadaver Studies , 2016, Investigative radiology.

[4]  Shuai Leng,et al.  Electronic noise in CT detectors: Impact on image noise and artifacts. , 2013, AJR. American journal of roentgenology.

[5]  Baiyu Chen,et al.  Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array , 2016, Physics in medicine and biology.

[6]  E. Ritman,et al.  How Low Can We Go in Radiation Dose for the Data-Completion Scan on a Research Whole-Body Photon-Counting Computed Tomography System , 2016, Journal of computer assisted tomography.

[7]  Edgar Kraft,et al.  A research prototype system for quantum-counting clinical CT , 2010, Medical Imaging.

[8]  Katharina Hahn,et al.  Low-dose performance of a whole-body research photon-counting CT scanner , 2016, SPIE Medical Imaging.

[9]  J. O’Sullivan,et al.  Properties of preprocessed sinogram data in x-ray computed tomography. , 2006, Medical physics.

[10]  Shuai Leng,et al.  Reducing Image Noise in Computed Tomography (CT) Colonography: Effect of an Integrated Circuit CT Detector , 2014, Journal of computer assisted tomography.

[11]  E. Nygard,et al.  Photon counting energy dispersive detector arrays for x-ray imaging , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.